Visian Toric ICL (Implantable Collamer Lens for Myopia) TMICL 13.2 (-8.5/3.0)Recalls & reported problems
Staar Surgical Company · Diopter: -8.5; Cylinder 3.0; Overall Diameter (Length): 13.2 · Class 3 · Implant
All models of Visian Toric ICL (Implantable Collamer Lens for Myopia) (293)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00841542108843), received between Mar 11, 2019 and Mar 11, 2019 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Ejection Problem” (2 reports).
8 other recalls cover devices cleared under the same FDA submission (P030016); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Ejection Problem2
- Improper or Incorrect Procedure or Method2
Patient problems
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 11, 2019Improper or Incorrect Procedure or Method; Ejection Problem; Improper or Incorrect Procedure or Method; Ejection Problem
THE REPORTER INDICATED THAT AS THE SURGEON WAS ATTEMPTING TO IMPLANT A 13.2MM TMICL13.2 IMPLANTABLE COLLAMER LENS, -8.5/+3.0/090 (SPHERE/CYLINDER/AXIS) INTO THE PATIENT'S RIGHT EYE (OD), THE LENS TORE. THERE WAS PATIENT CONTACT WITH THE LENS, WHICH WAS REMOVED INTRAOPERATIVELY ON (B)(6) 2019. LENS WAS NOT FULLY IMPLANTED. REPORTEDLY, THE SURGEON WAS NOT ADVANCING THE ICL TO THE TIP OF THE CARTRIDGE. WHEN HE PUSHED THE PLUNGER DOWN THE BARREL, IT OVERRODE THE ICL AND TRAPPED THE TRAILING HAPTICS IN THE TIP OF THE CARTRIDGE, TAKING A "BITE" OUT OF THE ICL. AN ALTERNATE LENS WAS SUCCESSFULLY IMPLANTED ON (B)(6) 2019. THERE WAS NO PATIENT INJURY. REFERENCE MFR REPORT# 2023826-2019-00383 FOR BACK-UP LENS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8409335 ↗MalfunctionMar 11, 2019Improper or Incorrect Procedure or Method; Ejection Problem; Improper or Incorrect Procedure or Method; Ejection Problem
THE REPORTER INDICATED THAT AS THE SURGEON WAS ATTEMPTING TO IMPLANT A 13.2MM TMICL13.2 IMPLANTABLE COLLAMER LENS, -8.5/+3.0/092 (SPHERE/CYLINDER/AXIS) INTO THE PATIENT'S RIGHT EYE (OD), THE LENS TORE. THERE WAS PATIENT CONTACT WITH THE LENS, WHICH WAS REMOVED INTRAOPERATIVELY ON (B)(6) 2019. LENS WAS NOT FULLY IMPLANTED. REPORTEDLY, THE SURGEON WAS NOT ADVANCING THE ICL TO THE TIP OF THE CARTRIDGE. WHEN HE PUSHED THE PLUNGER DOWN THE BARREL, IT OVERRODE THE ICL AND TRAPPED THE TRAILING HAPTICS IN THE TIP OF THE CARTRIDGE, TAKING A "BITE" OUT OF THE ICL. AN ALTERNATE LENS WAS SUCCESSFULLY IMPLANTED ON (B)(6) 2019. THERE WAS NO PATIENT INJURY. REFERENCE MFR REPORT# 2023826-2019-00379 FOR PRIMARY LENS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8409312 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P030016. One submission often covers many models, so check the product and lot details in each record.
- Z-1480-2026 · Jan 21, 2026 · Open, ClassifiedEVO+ Visian Toric Implantable Collamer Lens (TICL), Model: VTICM5
- Z-0466-2024 · Sep 29, 2023 · Open, ClassifiedEVO+VISIAN Implantable Collamer Lens, REF: VICM5_13.2. Phakic Intraocular lens.
- Z-0468-2024 · Sep 29, 2023 · Open, ClassifiedEVO VISIAN Implantable Collamer Lens, REF: VICMO12.1. Phakic Intraocular lens.
- Z-0469-2024 · Sep 29, 2023 · Open, ClassifiedEVO VISIAN Implantable Collamer Lens REF: VICMO13.2. Phakic Intraocular lens.
- Z-0467-2024 · Sep 29, 2023 · Open, ClassifiedEVO +VISIAN Implantable Collamer Lens, REF: VICM5_13.7.Phakic Intraocular lens.
- Z-0464-2024 · Sep 29, 2023 · Open, ClassifiedEVO+VISIAN Implantable Collamer Lens, REF:VICM5_12.1. Phakic Intraocular lens.
- Z-0465-2024 · Sep 29, 2023 · Open, ClassifiedEVO+VISIAN Implantable Collamer Lens, REF: VICM5_12.6. Phakic Intraocular lens.
- Z-0474-2024 · Sep 29, 2023 · Open, ClassifiedEVO VISIAN Implantable Collamer Lens, REF: VICMO12.6. Phakic Intraocular lens.
Other Phakic Toric Intraocular Lens devices
- EVO/EVO+VISIAN Implantable Collamer Lens VTICM5 13.2 (-13.0/1.0)Staar Surgical Company · Phakic Toric Intraocular Lens1 recall4 reports
- EVO/EVO+VISIAN Implantable Collamer Lens VTICM5 12.6 (-13.5/1.5)Staar Surgical Company · Phakic Toric Intraocular Lens1 recall4 reports
- EVO/EVO+VISIAN Implantable Collamer Lens VTICM5 12.6 (-8.5/2.0)Staar Surgical Company · Phakic Toric Intraocular Lens1 recall4 reports
- EVO/EVO+VISIAN Implantable Collamer Lens VTICM5 12.1 (-5.0/1.0)Staar Surgical Company · Phakic Toric Intraocular Lens1 recall4 reports
- EVO/EVO+VISIAN Implantable Collamer Lens VTICM5 12.6 (-11.5/2.5)Staar Surgical Company · Phakic Toric Intraocular Lens1 recall3 reports
- EVO/EVO+VISIAN Implantable Collamer Lens VTICM5 12.6 (-14.0/2.0)Staar Surgical Company · Phakic Toric Intraocular Lens1 recall3 reports
- EVO/EVO+VISIAN Implantable Collamer Lens VTICM5 12.6 (-5.5/1.5)Staar Surgical Company · Phakic Toric Intraocular Lens1 recall3 reports
- EVO/EVO+VISIAN Implantable Collamer Lens VTICM5 12.6 (-7.5/1.0)Staar Surgical Company · Phakic Toric Intraocular Lens1 recall3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page