Zavation 360-H092700Recalls & reported problems

Zavation LLC · eZspand PLIF/T-PLIF 9x27x0°, 10.5-15mm · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842166126480), received between Apr 21, 2025 and Apr 21, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Patient Device Interaction Problem1

Patient problems

  • Inadequate Osseointegration1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 21, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    ORIGINAL SURGERY WAS (B)(6) 2025. SURGEON REVIEWED 3 MONTHS POST OP IMAGES AND NOTICED THAT THE CAGE IS HAS BACKED OUT OF THE DISC SPACE 1CM APPROXIMATELY. CAGE DOES NOT LOOK COLLAPSED IN IMAGE. PATIENT HAD SUBSEQUENT RADICULAR LEG PAIN DUE TO CAGE POSITION. THE PATIENT REQUIRED EXPLANT SURGERY TO REMOVE CAGE. SURGERY TOOK PLACE ON (B)(6) 2025. SURGEON IS MONITORING 2 OTHER PATIENTS WHERE CAGES LOOK TO BE POSTERIOR BACKING OUT OF DISK SPACE BUT NOT COLLAPSED. BOTH PATIENTS ARE ASSYMPTOMATIC.

    Patient problems: Inadequate Osseointegration

    MAUDE report 21877724 ↗

Other Intervertebral Fusion Device With Bone Graft, Lumbar devices