Stent FREDX2518-PMARecalls & reported problems

Microvention, Inc. · FRED-X 21 · Class 3 · Implant

All models of Stent (63)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
11
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 00842429114223), received between Apr 4, 2022 and Mar 17, 2026 — classified as 11 injuries.

The most frequently reported specific device problem is “Difficult or Delayed Separation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem7
  • Difficult or Delayed Separation1
  • Difficult to Open or Close1
  • Entrapment of Device1
  • Material Twisted/Bent1
  • Migration1
  • Retraction Problem1

Patient problems

  • Thrombosis/Thrombus7
  • No Clinical Signs, Symptoms or Conditions2
  • Obstruction/Occlusion1
  • Paralysis1
  • Ruptured Aneurysm1

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 17, 2026Adverse Event Without Identified Device or Use Problem

    AS REPORTED: A CLOT FORMED ON THE PROXIMAL END OF THE FREDX. INTEGRILIN WAS GIVEN. THE ANEURYSM RUPTURED AND AN EVD WAS PLACED. I AM NOT AWARE OF OUTCOME.

    Patient problems: Ruptured Aneurysm; Thrombosis/Thrombus

    MAUDE report 24614237 ↗
  • InjuryJun 19, 2025Entrapment of Device; Material Twisted/Bent; Migration; Entrapment of Device; Material Twisted/Bent; Migration

    IT WAS REPORTED THAT A FREDX21 STENT WAS CHOSEN TO TREAT AN A2 ANEURYSM WITH THE VESSEL SIZE MEASURING 2.39 AND 2.02. A PIPELINE WAS TRIED, BUT IT WOULDN¿T NAVIGATE TO THE TARGET SITE. THE DOCTOR THEN OPTED TO USE THE FREDX21. WHEN THIS FIRST STENT WAS DEPLOYED IN THE A2 SEGMENT, IT MIGRATED BACK TO THE A1 AFTER DEPLOYMENT. THEN, THE IMPLANTED STENT WAS CROSSED, AND A SECOND STENT WAS DEPLOYED. IT DEPLOYED NICELY UNTIL THE PROXIMAL 3RD, AND THE WHOLE SYSTEM GOT JAMMED UP AND PULLED BACK THE SECOND STENT AND MANGLED WITH THE FIRST STENT THAT MIGRATED. THERE WAS NO PATIENT INJURY REPORTED, AND THERE WERE NO ADDITIONAL SURGICAL INTERVENTIONS PERFORMED NOR REQUIRED. THE PATIENT IS DOING FINE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22290636 ↗
  • InjuryMay 1, 2025Difficult to Open or Close; Difficult to Open or Close

    IT WAS REPORTED THAT DURING THE PROCEDURE, THE DOCTOR ATTEMPTED TO FLOW DIVERT ACOMM ANEURYSM WITH A 1.6-1.8 MM VESSEL SIZE USING A FLOW DIVERTER, AND THE DEVICE WOULD NOT OPEN. TWO ATTEMPTS WERE MADE TO RECAPTURE THE FLOW DIVERTER. ALSO, A STRETCH AND RELEASE METHOD WAS TRIED. WHEN THE FLOW DIVERTER WAS STILL HALF DEPLOYED, THE DOCTOR DID A DSA, AND THE IMAGE SHOWED A CLOT IN ACA. ASPIRATION WAS USED TO GET THE CLOT AND FLOW DIVERTER OUT OF THE ACA. THE FLOW DIVERTER WAS REMOVED FROM THE PATIENT AND DISCARDED. THE CASE WAS COMPLETED BY PLACING A SECOND STENT. THE PATIENT WAS ADMINISTERED ASPIRATION AND THROMBOLYTICS MEDICATION. THE PATIENT WAS INTACT POST-PROCEDURE.

    Patient problems: Thrombosis/Thrombus

    MAUDE report 21946895 ↗
  • InjuryJan 13, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE FREDX21 DEVICE WAS SUCCESSFULLY IMPLANTED IN THE A2 TO TREAT A WIDE NECK ANEURYSM AND EVERYTHING LOOKED GREAT. IN PACU, THE PATIENT STARTED TO HAVE PARALYSIS ON RIGHT SIDE. INTEGRILIN WAS GIVEN BEDSIDE AND IT CLEARED UP THE CLOT. PATIENT IS NOW ASYMPTOMATIC & STABLE.

    Patient problems: Paralysis

    MAUDE report 21146221 ↗
  • InjuryMar 25, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    NO ADDITIONAL INFORMATION WAS RECEIVED.

    Patient problems: Thrombosis/Thrombus

    MAUDE report 18969684 ↗
  • InjuryOct 26, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT SEVEN DAYS POST-IMPLANTATION OF A FLOW DIVERTER IN THE RIGHT PERICALLOSAL ARTERY, THE PATIENT RETURNED FOR TREATMENT OF THE RIGHT ANTERIOR COMMUNICATING ARTERY, PATIENT IS ASX, ASYMPTOMATIC. UPON INJECTION OF CONTRAST THE PHYSICIAN NOTICED BLOCKAGE OF THE STENT AND PROXIMAL AND DISTAL TO IT AFTER STENT COILING OF THE ACA ANTERIOR CEREBRAL ARTERY WITH AND LVIS. THE LVIS ACUTELY CLOTTED OFF AS WELL AS MCA MIDDLE CEREBRAL ARTERY. HEPARIN WAS ON BOARD AS WELL AS BRILINTA. IA INTEGRILLIN GIVEN FOUR TIMES. THE MD NOTED THAT CLOTTING WORSENED AFTER SUBSEQUENT INJECTION OF HEPARIN AND SUSPECTED CLOTTING DISORDER, POSSIBLY HIT. THE PATIENT AWAKENED AND WAS ABLE TO FOLLOW MOTOR COMMANDS. THE PATIENT WAS TESTED/SCREENED FOR CLOTTING DISORDERS AND TESTED POSITIVE FOR FACTOR5. THE PATIENT PASSED AWAY EIGHTEEN DAYS POST-IMPLANTATION OF THE FIRST FLOW DIVERTER CAUSED BY ISSUES UNRELATED TO THE PROCEDURE/IMPLANT.

    Patient problems: Thrombosis/Thrombus

    MAUDE report 18008897 ↗
  • InjuryApr 28, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    N/A.

    Patient problems: Obstruction/Occlusion

    MAUDE report 16834381 ↗
  • InjuryApr 18, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THE PHYSICIAN PLACED THE FLOW DIVERTER FROM THE RT PCA TO THE RIGHT PCOMM AND COILED THE ANEURYSM THROUGH THE VERT. IT WAS NOTED THAT POST PROCEDURE EVERYTHING LOOKED GOOD. THE PHYSICIAN DID A FOLLOW UP A WEEK LATER AND NOTICED THROMBUS IN THE STENT AND GAVE SOME THROMBOLYTICS. THE MEDICATION CLEARED THE THROMBUS UP. THE PHYSICIAN DID THE 6 MONTH FOLLOW UP AND THE STENT WAS COMPLETELY THROMBOSED. THE PCA WAS BEING FILLED BY COLLATERALS FROM THE ACA AND MCA. THE PATIENT WAS DOING WELL, DEVICE REMAINS IMPLANTED.

    Patient problems: Thrombosis/Thrombus

    MAUDE report 16765645 ↗
  • InjuryMar 6, 2023Retraction Problem; Retraction Problem

    IT WAS REPORTED THAT AFTER DEPLOYING THE FLOW DIVERTER, PHYSICIAN EXPERIENCED A LOT OF RESISTANCE PULLING THE PUSHER WIRE OUT OF THE HEADWAY. IT WAS THOUGHT THAT THE PUSHER WIRE BUMPER BECAME STUCK ON THE PROXIMAL FINISHED ENDS OF THE FLOW DIVERTER. ULTIMATELY, THE SOFIA WAS BROUGHT ALL THE WAY UP, TO PULL EVERYTHING INTO THE SOFIA. THIS TOOK A FEW ATTEMPTS, AND ULTIMATELY FREED THE WIRE FROM THE FLOW DIVERTER. A TRANSFORM BALLOON WAS INFLATED FOR A FEW MINUTES AND THE BLEEDING STOPPED. THE FLOW DIVERTER DIDN¿T MOVE AND STILL COVERED THE ANEURYSM. NO REPORTED INJURY TO THE PATIENT. THE PATIENT WAS REPORTED AS OK AFTER WAKING UP.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16487143 ↗
  • InjuryOct 18, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING TREATMENT OF AN ANEURYSM RUPTURE, A FRED DEVICE WAS IMPLANTED. A CLOT DEVELOPED INSIDE THE FRED AND FLOW WAS LOST TO THE LEFT A2. TWO DOES OF INTEGRALIN WERE ADMINISTERED. THE FRED WAS REPORTED TO SHUT DOWN AND BOTH ACA'S WERE REPORTED TO BE OCCLUDED.

    Patient problems: Thrombosis/Thrombus

    MAUDE report 15629458 ↗
  • InjuryApr 4, 2022Difficult or Delayed Separation; Difficult or Delayed Separation

    IT WAS REPORTED THAT DURING THE PROCEDURE, THE FRED X21 STENT WAS DELIVERED WITHOUT INCIDENT. INTRA-STENT THROMBUS WAS OBSERVED POST DELIVERY AND WAS RESOLVED WITH INTRA-ARTERIAL CANGRELOR AND INTEGRILIN. THERE WAS NO PATIENT HARM REPORTED, WHO WAS REPORTED TO BE DOING WELL.

    Patient problems: Thrombosis/Thrombus

    MAUDE report 14003416 ↗

Other Intracranial aneurysm flow diverter devices

All Intracranial aneurysm flow diverter devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page