Skip to content

Stent FREDX3531-PMARecalls & reported problems

Microvention, Inc. · FRED-X 27 · Class 3 · Implant

All models of Stent (63)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842429114322), received between Aug 22, 2024 and Aug 22, 2024 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Muscle Weakness/Atrophy1
  • Stroke/CVA1
  • Thrombosis/Thrombus1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 22, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED, "ICA OPTHALMIC ANEURYSM TO BE TREATED WITH A FREDX DEVICE. DEPLOYED FROM ICA TERMINUS, ACROSS THE NEXT OF ANEURYSM AND INTO THE CAVERNOUS ICA. STENOTIC AREA OF VESSEL/FREDX NEAR THE PROXIMAL NECK OF ANEURYSM PROXIMAL TO THE OPTHALMIC ARTERY. A 4X10 SEPTER BALLOON WAS USED TO DILATE, BUT DID NOT INCREASE DIAMETER OF STENOTIC AREA. FINAL IMAGES WERE OBTAINED WITH GOOD FLOW THROUGH AND DISTAL OF THE IMPLANT. PATIENT WAS WOKE FROM ANASTESHIA WITH HEMIPARALYSIS, WAS PUT BACK ON THE TABLE TO FIND THE OCCLUSIVE THROMBUS NEAR STENOTIC PORTION. A TENZIG CATHETER WAS SENT INTO THE M1 AND A FREE CLIMB ASPIRATION CATHETER WAS BROUGHT UP TO THE ORIGIN OF THE CLOT. ONE SEGMENT OF ASPIRATION WAS PERFORMED. UPON IMAGING POST ASPIRATION BLEEDING WAS OBSERVED. A BALLOON WAS DELIVERED TO TAMPONADE THE BLEED, AND 7 COILS WERE THEN IMPLANTED IN THROUGH THE ICA DOWN PAST THE OPTHALMIC TO SACRIFICE THE VESSEL AND STOP THE BLEEDING. THIS WAS BELIEVED TO BE DUE TO A STENOTIC VESSEL. THE PATIENT IS ALIVE AND HAD A LARGE L MCA STROKE. HAD TO DO DECOMPRESSIVE CRANIECTOMY AND WILL HAVE RIGHT SIDED HEMIPLEGIA AND SPEECH DEFICITS/APHASIA.THE PATIENT IS ALIVE AND HAD A LARGE L MCA STROKE. HAD TO

    Patient problems: Muscle Weakness/Atrophy; Stroke/CVA; Thrombosis/Thrombus

    MAUDE report 20028323 ↗

Other Intracranial aneurysm flow diverter devices

All Intracranial aneurysm flow diverter devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page