Stent FREDX4534-PMARecalls & reported problems

Microvention, Inc. · FRED-X 27 · Class 3 · Implant

All models of Stent (63)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00842429114421), received between Mar 30, 2026 and Mar 30, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Activation Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 30, 2026Activation Problem

    IT WAS REPORTED FOR A PATIENT ENROLLED IN THE CAR (COMPLEX ANEURYSM REGISTRY) STUDY THAT A SEGMENT OF A FREDX DEVICE DID NOT COMPLETELY OPEN DURING PROCEDURE. A NON-RUPTURED, RIGHT MCA BIFURCATION ANEURYSM WAS TREATED WITH A FREDX DEVICE. THE SPONSOR REVIEW OF INDEX PROCEDURE NOTE IDENTIFIED A SEGMENT OF A FREDX DEVICE DID NOT COMPLETELY OPEN DURING PROCEDURE. AT THIS TIME, THE FRED-X DELIVERY SYSTEM WAS TAKEN THROUGH THE MICROCATHETER. THE DEVICE WAS DEPLOYED WITH THE DISTAL LANDING ZONE NEAR THE OPHTHALMIC ARTERY AND THE PROXIMAL LANDING JUST PROXIMAL TO THE HORIZONTAL PETROUS SEGMENT. THERE WAS GOOD WALL APPOSITION OF THE DEVICE ON INTERMITTENT ANGIOGRAPHY PROXIMALLY AND DISTALLY OUT BUT THERE WAS A SEGMENT THAT DIDN'T APPEAR TO OPEN FULLY ACROSS THE PROXIMAL PORTION OF THE ANEURYSM NECK. FOR THIS REASON, WE DECIDED TO ANGIOPLASTY THE DEVICE. THE MICROCATHETER WAS TAKEN BACK OVER THE DELIVERY WIRE THROUGH THE PROXIMAL 2/3'S OF THE STENT FOLLOWED BY COMPLETE WITHDRAWAL OF THE DELIVERY WIRE. THE GUIDEWIRE WAS THEN INSERTED THROUGH THE MICROCATHETER AND ADVANCED OUT OF THE FLOW DIVERTING STENT AND INTO THE RIGHT M1. THE MICROCATHETER WAS EXCHANGED OFF FOR THE BALLOON. THE BALLOON W

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24715745 ↗

Other Intracranial aneurysm flow diverter devices

All Intracranial aneurysm flow diverter devices →