HEADWAY MC172150SX-ALRecalls & reported problems

Microvention, Inc. · Headway Advanced · Class 2

All models of HEADWAY (10)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00842429117439), received between Apr 24, 2025 and Sep 23, 2026 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Difficult to Advance1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Foreign Body In Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 23, 2026Break

    It was reported that when the microcatheter Headway-17 was opened the device was straight, but when the microguide was advanced by 0.014 mm, the doctor realized it wasn't progressing. He tried repeatedly, but it was never possible. The device was inspected and found to be fractured in the proximal portion. Another device is used to resolve the case. The patient is in good clinical condition.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50872020 ↗
  • MalfunctionDec 4, 2025Difficult to Advance; Difficult to Advance

    IT WAS REPORTED THAT THE GUIDE WIRE DID NOT PASS SMOOTHLY THROUGH THE MICROCATHETER. A NEW CATHETER WAS USED TO COMPLETE THE CASE. THE PATIENT IS IN STABLE CONDITION. ADDITIONAL INFORMATION WAS RECEIVED FROM THE POST EVALUATION REPORT REVEALED AN EXPOSED COIL AND DAMAGED/MISSING PTFE LINING AT THE HUB TRANSITION, WHICH WOULD HAVE CONTRIBUTED TO THE RESISTANCE ENCOUNTERED DURING THE INVESTIGATION. THE PTFE DAMAGE/DELAMINATION AND RESULTING OCCLUSION ARE CONSISTENT WITH ADVANCING ANOTHER DEVICE THROUGH THE MICROCATHETER WITH EXPOSED COIL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23717878 ↗
  • InjuryApr 24, 2025Break; Break

    ADDITIONAL CLARIFYING INFORMATION RECEIVED NOTES THAT THE TYPE OF CASE PERFORMED WAS FOR A STENT COIL PROCEDURE. THE HEADWAY MICROCATHETER WAS PLACED WITHIN THE ANEURYSM, AND THE STENT WAS PLACED USING ANOTHER HEADWAY MICROCATHETER. AFTER COMPLETING THE COILING, THE DOCTOR TRIED TO REMOVE THE MICROCATHETER, BUT IT CAUGHT THE STENT CELL AND THE MICROCATHETER DISTAL TIP WAS TORN OFF. THE PROCEDURE WAS FINISHED WITH THE DISTAL TIP OF THE MICROCATHETER REMAINING IN THE PATIENT BODY. THERE IS NO PLAN TO ADDRESS PIECE REMAINING IN THE PATIENT AND WE WILL WATCH THE PROGRESS OF THE PATIENT. THE DEVICE IS CURRENTLY PENDING RECEIPT.

    Patient problems: Foreign Body In Patient

    MAUDE report 21906174 ↗