HEADWAY MC17215045X-ALRecalls & reported problems
Microvention, Inc. · Headway Advanced · Class 2
All models of HEADWAY (10)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00842429117446), received between Feb 19, 2026 and Mar 31, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Material Protrusion/Extrusion” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Protrusion/Extrusion2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 31, 2026Material Protrusion/Extrusion
AS REPORTED, IMPOSSIBLE TO INTRODUCE THE WEB IN 3 MICROCATHETERS: (X2) VIA 17 AND (X1) HEADWAY 17, LOT: 000993008. THE PHYSICIAN FINALLY DECIDED TO USE AN ARTISSE. THERE WAS NO REPORT OF INJURY. NO CONSEQUENCE FOR THE PATIENT. WHEN THE DEVICE, HEADWAY 17 MICROCATHETER WAS RECEIVED FOR EVALUATION, THE INVESTIGATION FINDINGS REVEALED AN EXPOSED LUMEN COIL PROTRUDING INTO THE CATHETER LUMEN. THEREFORE, A REPORT IS BEING SUBMITTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24748663 ↗MalfunctionFeb 19, 2026Material Protrusion/Extrusion
IT WAS REPORTED THAT THE COIL WOULD NOT ADVANCE PAST THE HUB OF THE MICROCATHETER. THE MICROCATHETER AND COIL WERE BOTH REMOVED FROM THE PATIENT WITHOUT ANY ADVERSE EVENTS. THERE WAS NO PATIENT INJURY. WHEN THE DEVICE WAS RECEIVED FOR EVALUATION, THE INVESTIGATION FINDINGS FOUND THE LUMEN TO NOT BE FULLY FLARED AT THE HUB JOINT WITH EXPOSED BRAID IN THE LUMEN, AND DELAMINATED PTFE WAS IN THE LUMEN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24396990 ↗
Other Catheter, percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page