Dimension® CSA Flex® reagent cartridge 10285193Recalls & reported problems
Siemens Healthcare Diagnostics Inc. · Cyclosporine Flex® reagent cartridge, 80 tests · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00842768025136), received between Mar 5, 2020 and Feb 26, 2025 — classified as 4 malfunctions.
The most frequently reported specific device problem is “High Test Results” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- High Test Results3
- Low Test Results1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 26, 2025Low Test Results; Low Test Results
THE CUSTOMER REPORTED TO SIEMENS THAT AN ERRONEOUSLY DEPRESSED CYCLOSPORINE A (CSA) RESULT WAS OBTAINED ON A PATIENT SAMPLE ON A DIMENSION RXL MAX HM INTEGRATED CHEMISTRY SYSTEM. THE ERRONEOUSLY DEPRESSED RESULT WAS NOT REPORTED TO THE PHYSICIAN(S). THE SAME SAMPLE WAS REPROCESSED TWICE ON THE ORIGINAL DIMENSION RXL MAX HM INTEGRATED CHEMISTRY SYSTEM. HIGHER REPROCESSED RESULTS WERE OBTAINED AND CONSIDERED CORRECT. THE HIGHER REPROCESSED RESULT OF 116.3 NG/ML WAS REPORTED TO THE PHYSICIAN(S). THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE ERRONEOUSLY DEPRESSED CYCLOSPORINE A (CSA) RESULT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21466684 ↗MalfunctionJul 1, 2024High Test Results; High Test Results
THE CUSTOMER REPORTED ONE (1) ERRONEOUSLY ELEVATED CYCLOSPORINE A (CSA) PATIENT SAMPLE RESULT WAS OBTAINED ON A DIMENSION® EXL¿ 200 INTEGRATED CHEMISTRY SYSTEM. THE ERRONEOUSLY ELEVATED PATIENT RESULT WAS NOT REPORTED TO THE PHYSICIAN. THE SAME SAMPLE WAS MANUALLY DILUTED AND REPROCESSED TWO TIMES ON THE SAME DIMENSION® EXL¿ 200 INTEGRATED CHEMISTRY SYSTEM. LOWER RESULTS WERE OBTAINED, CONSIDERED CORRECT AND REPORTED TO THE PHYSICIAN. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE ERRONEOUSLY ELEVATED CYCLOSPORINE A (CSA) RESULT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19642732 ↗MalfunctionJun 2, 2023High Test Results; High Test Results
TWO (2) DISCORDANT FALSELY ELEVATED CYCLOSPORINE A (CSA) RESULTS WERE OBTAINED ON A PATIENT SAMPLE ON A DIMENSION EXL 200 SYSTEM. ONE OF THE FALSELY ELEVATED RESULTS WAS REPORTED TO THE PHYSICIAN(S), AND THE RESULT WAS QUESTIONED. THE SAME SAMPLE WAS REPROCESSED ON AN ALTERNATE DIMENSION EXL 200 SYSTEM, AND THE REPROCESSED RESULT WAS CONSIDERED CORRECT. A CORRECTED REPORT WAS ISSUED. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE FALSELY ELEVATED CYCLOSPORINE A (CSA) RESULTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17049053 ↗MalfunctionMar 5, 2020High Test Results; High Test Results
DISCORDANT, FALSELY DEPRESSED CYCLOSPORINE A (CSA) RESULTS WERE OBTAINED ON PATIENTS' SAMPLES ON A DIMENSION EXL 200 INSTRUMENT. THE RESULTS WERE NOT REPORTED TO THE PHYSICIAN(S). AFTER A NEW FLEX WAS PUT ON-BOARD AND A RE-CALIBRATION WAS PERFORMED, EACH PATIENT SAMPLE WAS REPROCESSED ON THE SAME DATE ON THE INSTRUMENT AND A HIGHER CORRECT RESULT WAS OBTAINED. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION DUE TO THE DISCORDANT, FALSELY DEPRESSED CYCLOSPORINE A RESULTS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9795378 ↗
Other CYCLOSPORINE devices
- Atellica IM CsA 10995548Siemens Healthcare Diagnostics Inc. · CYCLOSPORINE2 reports
- ADVIA Centaur® CsA 10335448Siemens Healthcare Diagnostics Inc. · CYCLOSPORINE1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page