RelayPro Thoracic Stent-Graft System 28-M4-34-145-34URecalls & reported problems

Bolton Medical Inc. · Endovascular Stent-Graft System · Class 3 · Implant

All models of RelayPro Thoracic Stent-Graft System (127)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
1

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00843576149786), received between Oct 2, 2024 and Dec 20, 2024 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Device Endoleak” (2 reports).

1 FDA recall record name this device's identifier, 1 still open.

2 other recalls cover devices cleared under the same FDA submission (P200045); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 2 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Dec 20, 2022Class IIOpen, Classified

    The product may be shorter than packaging indicates

    Z-0997-2023 · Root cause: Labeling Change Control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Device Endoleak2
  • Difficult or Delayed Separation1
  • Difficult to Advance1

Patient problems

  • Clinical Endoleak2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 20, 2024Device Endoleak; Device Endoleak

    "ENDOLEAK (MINOR TYPE IA ENDOLEAK REMAINED): ONLY 2-DEBRANCHING WAS PERFORMED ON NOVEMBER 15, AND TEVAR WAS THEN PERFORMED ON NOVEMBER 22. AS THE ACCESS ARTERY COULD NOT BE PUNCTURED DUE TO ITS POOR CONDITION, A CUT-DOWN METHOD WAS USED INSTEAD. TEVAR WAS THEN PERFORMED AS USUAL. AS A 200 MM LONG STENT-GRAFT WOULD BE TOO LONG, TWO 150 MM LONG STENT-GRAFTS WERE USED. THE STENT-GRAFT CONCERNED (28-M4-34-145-34U, LOT#2406220121) WAS FIRST IMPLANTED FROM RIGHT UNDER ZONE 1, AND THE SECOND STENT-GRAFT (28-M4-34-145-34U, LOT#2407190457) WAS THEN IMPLANTED RIGHT ABOVE A DESCENDING THORACIC AORTIC ANEURYSM ON THE DISTAL SIDE. THE FINAL ANGIOGRAPHY REVEALED A TYPE IA ENDOLEAK. AFTER CAREFUL POST DILATATION, ANOTHER ANGIOGRAPHY CONFIRMED THAT A SLIGHT TYPE IA ENDOLEAK REMAINED. SINCE THE DESCENDING THORACIC AORTIC ANEURYSM ON THE DISTAL SIDE IS GOING TO BE TREATED IN THE NEAR FUTURE, THIS PROCEDURE WAS COMPLETED AND THE PATIENT WAS TO BE FOLLOWED UP. ADDITIONAL INFORMATION OBTAINED ON NOVEMBER 27: CONTRAST-ENHANCED CT CONFIRMED ON NOVEMBER 26 THAT THE ENDOLEAK HAD DISAPPEARED OPERATION TYPE: 2-DEBRANCHING TEVAR BLOOD LOSS: UNKNOWN. NO IMAGE AVAILABLE DUE TO HOSPITAL POLICY. PRE-CASE PLAN AVA

    Patient problems: Clinical Endoleak

    MAUDE report 20989450 ↗
  • InjuryDec 20, 2024Device Endoleak; Device Endoleak

    "ENDOLEAK (MINOR TYPE IA ENDOLEAK REMAINED): ONLY 2-DEBRANCHING WAS PERFORMED ON NOVEMBER 15, AND TEVAR WAS THEN PERFORMED ON NOVEMBER 22. AS THE ACCESS ARTERY COULD NOT BE PUNCTURED DUE TO ITS POOR CONDITION, A CUT-DOWN METHOD WAS USED INSTEAD. TEVAR WAS THEN PERFORMED AS USUAL. AS A 200 MM LONG STENT-GRAFT WOULD BE TOO LONG, TWO 150 MM LONG STENT-GRAFTS WERE USED. THE STENT-GRAFT CONCERNED (28-M4-34-145-34U, LOT#2406220121) WAS FIRST IMPLANTED FROM RIGHT UNDER ZONE 1, AND THE SECOND STENT-GRAFT (28-M4-34-145-34U, LOT#2407190457) WAS THEN IMPLANTED RIGHT ABOVE A DESCENDING THORACIC AORTIC ANEURYSM ON THE DISTAL SIDE. THE FINAL ANGIOGRAPHY REVEALED A TYPE IA ENDOLEAK. AFTER CAREFUL POST DILATATION, ANOTHER ANGIOGRAPHY CONFIRMED THAT A SLIGHT TYPE IA ENDOLEAK REMAINED. SINCE THE DESCENDING THORACIC AORTIC ANEURYSM ON THE DISTAL SIDE IS GOING TO BE TREATED IN THE NEAR FUTURE, THIS PROCEDURE WAS COMPLETED AND THE PATIENT WAS TO BE FOLLOWED UP. ADDITIONAL INFORMATION OBTAINED ON NOVEMBER 27: CONTRAST-ENHANCED CT CONFIRMED ON NOVEMBER 26 THAT THE ENDOLEAK HAD DISAPPEARED OPERATION TYPE: 2-DEBRANCHING TEVAR. BLOOD LOSS: UNKNOWN. NO IMAGE AVAILABLE DUE TO HOSPITAL POLICY. PRE-CASE PLAN AV

    Patient problems: Clinical Endoleak

    MAUDE report 20989433 ↗
  • MalfunctionOct 2, 2024Difficult to Advance; Difficult or Delayed Separation; Difficult to Advance; Difficult or Delayed Separation

    "UNABLE TO ADVANCE THE INNER SHEATH: WHEN THE SALES REPRESENTATIVE ENTERED THE OPERATION ROOM, THE PHYSICIAN HAD ADVANCED THE DELIVERY SYSTEM TO THE LEFT SUBCLAVIAN ARTERY AND WAS ATTEMPTING TO DEPLOY THE STENT GRAFT WITH THE CONTROLLER PLACED IN POSITION "2". HOWEVER, THE SALES REPRESENTATIVE OBSERVED THAT ALTHOUGH THE DEPLOYMENT GRIP HAD ADVANCED PAST THE ARROW MARKER AND WAS SO CLOSE TO THE CONTROLLER THAT THERE WAS ALMOST NO DISTANCE TO THE CONTROLLER, THE INNER SHEATH HAD ONLY EXTENDED ONE STENT LENGTH OUT OF THE OUTER SHEATH. WHILE PRESSING THE DISENGAGEMENT BUTTON, THE REVERSE SLIDER TECHNIQUE WAS ATTEMPTED, BUT THE OUTER SHEATH WAS UNABLE TO BE RETRACTED. ROTATING THE DEPLOYMENT GRIP CLOCKWISE WAS ABLE TO ONLY PARTIALLY ADVANCE THE INNER SHEATH, LEAVING THREE STENT LENGTH OF INNER SHEATH REMAINING IN THE OUTER SHEATH, AND ALSO LEAVING NO SPACE BETWEEN THE CONTROLLER AND THE DEPLOYMENT GRIP FOR FURTHER MANIPULATION. THE CONTROLLER WAS PLACED IN THE "4" POSITION AND THE STAINLESS-STEEL ROD WAS PUSHED, BUT THE INNER SHEATH WAS UNABLE TO BE MOVED. SINCE THE REVERSE SLIDE TECHNIQUE WAS INEFFECTIVE, IT WAS DETERMINED THAT THERE WAS NO ALTERNATIVE BUT TO TURN THE DEPLOYMENT GRIP A

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20354220 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P200045. One submission often covers many models, so check the product and lot details in each record.

  • Z-2160-2026 · Apr 22, 2026 · Open, Classified
    RelayPro Thoracic Stent-Graft System (various sizes) Reference numbers: 28-N4-32-104-32U 28-N4-32-164-28U 28-N4-32-164-32U 28-N4-32-209-28U 28-N4-32-209-32U 28-N4-32-259-32U 28-N4-
  • Z-1383-2024 · Feb 22, 2024 · Completed
    RELAY PRO Thoracic Stent-Graft System, containing one endovascular stent-graft system, IFU, and patient tracking card, sterile: (a) Part number 28-M4-34-100-34U; (b) Part number 2