RelayPro Thoracic Stent-Graft System 28-M4-36-145-32URecalls & reported problems
Bolton Medical Inc. · Endovascular Stent-Graft System · Class 3 · Implant
All models of RelayPro Thoracic Stent-Graft System (127)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00843576150157), received between Oct 23, 2024 and Feb 24, 2026 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Difficult to Advance” (1 report).
2 other recalls cover devices cleared under the same FDA submission (P200045); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Difficult to Advance1
- Difficult to Insert1
- Material Integrity Problem1
- No Apparent Adverse Event1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryFeb 24, 2026Adverse Event Without Identified Device or Use Problem
"IMPLANTATION POSITIONING FAILURE / LEFT COMMON CAROTID ARTERY OCCLUSION: THE RELAYPRO WAS PLANNED TO BE IMPLANTED JUST BELOW THE LEFT SUBCLAVIAN ARTERY (ZONE 2). HOWEVER, THE PHYSICIAN IMPLANTED THE DEVICE MORE CENTRALLY THAN PLANNED, OCCLUDING THE LEFT COMMON CAROTID ARTERY. THE PROCEDURE WAS IMMEDIATELY CHANGED FROM ONE DEBRANCHING TEVAR TO TWO DEBRANCHING TEVAR TO RESTORE BLOOD FLOW. SUBSEQUENTLY, THE PROCEDURE WAS SUCCESSFULLY COMPLETED. OPERATION TYPE: TEVAR. BLOOD LOSS: UNKNOWN. NO IMAGE AVAILABLE DUE TO HOSPITAL POLICY. NO PRE-CASE PLAN AVAILABLE DUE TO HOSPITAL POLICY. NO ADDITIONAL INFORMATION AVAILABLE DUE TO HOSPITAL POLICY. ((B)(4))" PATIENT OUTCOME: "THERE WAS NO HEALTH DAMAGE TO THE PATIENT."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24428774 ↗MalfunctionOct 23, 2024Difficult to Insert; Difficult to Advance; Material Integrity Problem; No Apparent Adverse Event; Difficult to Insert; Difficult to Advance; Material Integrity Problem; No Apparent Adverse Event
"BROKEN/DEFECTIVE (BLACK PORTION AT THE TIP OF THE OUTER SHEATH WAS FOUND TO BE TURNED UP): WHEN THE DELIVERY SYSTEM WAS ATTEMPTED TO BE INSERTED INTO THE FEMORAL ARTERY, THE DELIVERY SYSTEM COULD NOT BE INSERTED DUE TO RESISTANCE. WHEN THE PHYSICIAN CHECKED THE TIP OF THE DELIVERY SYSTEM, THE BLACK PORTION AT THE TIP OF THE OUTER SHEATH WAS FOUND TO BE TURNED UP. THE PHYSICIAN PRESSED THE BLACK PORTION AT THE TIP OF THE OUTER SHEATH WITH HIS HAND TO ELIMINATE THE DEFORMATION AND THEN MADE A SLIGHTLY LARGER CUT IN THE FEMORAL ARTERY, WHICH ENABLED THE DELIVERY SYSTEM TO INSERT INTO THE ARTERY. WHEN RESISTANCE WAS FELT DURING INSERTION, THE PHYSICIAN DID NOT FORCE THE INSERTION BUT CONTINUED THE INSERTION SLOWLY WHILE CHECKING UNTIL THE DELIVERY SYSTEM SAFELY REACHED THE INTENDED POSITION. AFTER THAT, THE STENT-GRAFT WAS IMPLANTED, AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED. WHEN THE REMOVED DEVICE WAS CHECKED, ANOTHER PORTION OTHER THAN THE TIP PRESSED BY THE PHYSICIAN WAS FOUND TO BE TURNED UP AS WELL, WHICH WAS PHOTOGRAPHED (SEE THE IMAGE). AS THE DEVICE HAD NOT HIT ANYWHERE AND THERE WAS NO PLACE WHERE RESISTANCE WOULD BE APPLIED DURING INSERTION, IT WAS ASSUMED THAT THE PORTI
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20514802 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P200045. One submission often covers many models, so check the product and lot details in each record.
- Z-2160-2026 · Apr 22, 2026 · Open, ClassifiedRelayPro Thoracic Stent-Graft System (various sizes) Reference numbers: 28-N4-32-104-32U 28-N4-32-164-28U 28-N4-32-164-32U 28-N4-32-209-28U 28-N4-32-209-32U 28-N4-32-259-32U 28-N4-
- Z-1383-2024 · Feb 22, 2024 · CompletedRELAY PRO Thoracic Stent-Graft System, containing one endovascular stent-graft system, IFU, and patient tracking card, sterile: (a) Part number 28-M4-34-100-34U; (b) Part number 2
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page