TREO Abdominal Stent-Graft System 28-B2-28-080U (UDI 00843576152366)Recalls & reported problems

Bolton Medical Inc. · Endovascular Stent-Graft System · Class 3 · Implant

All models of TREO Abdominal Stent-Graft System (73)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00843576152366), received between Feb 10, 2025 and Feb 10, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Device Endoleak” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. May 3, 2023Class IIOpen, Classified

    Potential for the incorrect size stent-graft than the printed carton label.

    Z-1689-2023 · Root cause: Process control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Device Endoleak1
  • Failure to Seal1

Patient problems

  • Clinical Endoleak1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 10, 2025Failure to Seal; Device Endoleak; Failure to Seal; Device Endoleak

    "TREO BIFUR WAS OPENED AND PREPPED AS NORMAL. THE DEVICE WAS ADVANCED, POSITIONED AND DEPLOYED AS NORMAL. FOLLOWING CONTRALATERAL GATE CANNULATION, THE PROXIMAL CLASP WAS RELEASED, AND LASER FENESTRATIONS WERE CREATED FOR THE RIGHT AND LEFT RENAL ARTERIES. BRIDGING STENTS WERE PLACED IN EACH RENAL AND FLARED ACCORDINGLY. THE IPSILATERAL LEG WAS FULLY DEPLOYED, COMPLETING DEPLOYMENT OF THE TREO BIFUR AND THE DELIVERY SYSTEM WAS REMOVED FROM THE PATIENT AS NORMAL. THE CONTRALATERAL AND IPSILATERAL LIMBS WERE DETERMINED, OPENED AND PREPPED AS NORMAL. THE CONTRALATERAL LIMB WAS ADVANCED, POSITIONED AND DEPLOYED AS NORMAL. THE IPSILATERAL LIMB WAS ADVANCED, POSITIONED JUST ABOVE THE MINIMUM OVERLAP MARKER AND DEPLOYED AS NORMAL. A TERUMO AORTIC BALLOON WAS PREPPED, ADVANCED, AND ONLY USED IN THE OVERLAP BETWEEN THE BIFUR LEGS AND LIMBS, AS WELL AS THE DISTAL SEAL ZONES ON BOTH SIDES. NO BALLOONING ABOVE THE FABRIC LINE OF EACH LIMB OCCURRED AT THIS TIME. ON THE COMPLETION ANGIOGRAM AN ENDOLEAK WAS OBSERVED. IT WAS UNCLEAR WHERE THE LEAK WAS COMING FROM. THE PHYSICIAN BALLOONED THE MAIN BODY OF THE TREO BIFUR BELOW THE RENAL ARTERY STENTS AND THE ENTIRE CONTRALATERAL SIDE USING THE TERUM

    Patient problems: Clinical Endoleak

    MAUDE report 21350088 ↗

Other System, Endovascular Graft, Aortic Aneurysm Treatment devices

All System, Endovascular Graft, Aortic Aneurysm Treatment devices →