TREO Abdominal Stent-Graft System 28-B2-30-120URecalls & reported problems
Bolton Medical Inc. · Endovascular Stent-Graft System · Class 3 · Implant
All models of TREO Abdominal Stent-Graft System (73)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00843576152533), received between Jun 5, 2026 and Jun 5, 2026 — classified as 1 injury.
1 other recall cover devices cleared under the same FDA submission (P190015); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Aneurysm expansion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 5, 2026Adverse Event Without Identified Device or Use Problem
"ON (B)(6) 2026, THE CORE LAB SENT NOTIFICATION OF A SIGNIFICANT FINDING REGARDING >5MM GROWTH OF SUBJECT'S AORTA AT PROXIMAL ASPECT OF THE STENT FOR THEIR 3-YEAR CT DATED (B)(6) 2025 IN COMPARISON TO THE 30-DAY TIMEPOINT. THE INVESTIGATOR REVIEWED THE FINDING AND SUBJECT'S IMAGING AND DID NOT AGREE WITH THE CORE LAB'S ASSESSMENT, SPECIFYING THE FOLLOWING: "SUBJECT HAS NO CHANGE IN THE AORTIC NECK FROM IMPLANTATION. MEASUREMENT OF THE NECK ON THE AXIAL IMAGE ATTACHED OVERCALLS THE DIAMETER THAT IS INDEED ANEURYSMAL AT THE TOP OF THE UNCOVERED STRUTS OF THE TREO GRAFT. THERE IS ANGULATION THAT IS MAKING THAT DIAMETER LARGER THAN IT REALLY IS AND IS BEST SEEN IN THE SAGITTAL VIEW FOR MEASUREMENT. ON DIRECT COMPARISON OF THE INITIAL AND MOST RECENT CT, THERE IS NO CHANGE IN THE NECK AT THE TOP OF THE UNCOVERED STRUTS OR AT THE SHORT RING LIKE SEAL ZONE OF THE NECK SINCE IMPLANTATION. NO FURTHER ACTION IS REQUIRED." THE CSM INQUIRED AFTERWARDS WITH THE CORE LAB REGARDING THE SITE'S ASSESSMENT, AND CORE LAB SPECIFIED THAT PER THEIR CORE LAB PI "PROXIMAL AORTIC GROWTH IS PRESENT IN THE PROXIMAL ASPECT OF THE STENT BUT STILL APPEARS TO HAVE SEAL WITH MINIMAL GRAFT MOVEMENT". THE CORE LAB
Patient problems: Aneurysm expansion
MAUDE report 25415819 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P190015. One submission often covers many models, so check the product and lot details in each record.
- Z-1689-2023 · May 3, 2023 · Open, ClassifiedThe TREO ABDOMINAL STENT-GRAFT SYSTEM (TREO) consists of four types of implants, specifically a Main Bifurcated Stent-Graft, a Leg Extension Stent-Graft, a Proximal Cuff Stent-Graf
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page