Skip to content

OSSEOTITE® FNT3213Recalls & reported problems

ZimVie US Corp LLC · FULL OSSEOTITE® TAPERED IMPLANT 3.25 X 13MM · Class 2 · Implant

All models of OSSEOTITE (73)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00844868003298), received between Jul 23, 2021 and Sep 3, 2025 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Separation Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 2 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Separation Failure1

Patient problems

  • Pain2
  • Unspecified Infection2
  • Inflammation1
  • No Clinical Signs, Symptoms or Conditions1
  • Osteolysis1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjurySep 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE DOCTOR REPORTS THAT THE DENTAL IMPLANT LOCATED IN DENTAL POSITION NUMBER 14 FAILED DUE TO INFECTION. THE DOCTOR REPORTS IN THE PER THAT THE PROCEDURE WAS CONCLUDED BY PLACING ANOTHER IMPLANT. INFLAMMATION AND PAIN WERE REPORTED AS A RESULT OF THE EVENT.

    Patient problems: Inflammation; Pain; Unspecified Infection

    MAUDE report 22952067 ↗
  • InjurySep 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE DOCTOR REPORTS THAT THE DENTAL IMPLANT LOCATED IN DENTAL POSITION NUMBER #25 FAILED DUE TO PERI-IMPLANTITIS. THE DOCTOR REPORTS IN THE PER THAT THE PROCEDURE WAS CONCLUDED BY PLACING ANOTHER IMPLANT. PAIN AND INFLAMMATION WERE REPORTED AS A RESULT OF THE EVENT.

    Patient problems: Osteolysis; Pain; Unspecified Infection

    MAUDE report 22952057 ↗
  • MalfunctionJul 23, 2021Separation Failure; Separation Failure

    NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12216068 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page