Phoenix 2.2mm x 130cm 6F Atherectomy Catheter P22130Recalls & reported problems
Volcano Atheromed, Inc. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00845225002626), received between Feb 3, 2017 and Nov 10, 2021 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Improper or Incorrect Procedure or Method1
Patient problems
- Device Embedded In Tissue or Plaque2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 10, 2021Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method
IT WAS REPORTED THAT DURING A THERAPEUTIC PERIPHERAL PROCEDURE IN A SLIGHTLY CALCIFIED SFA, THE MANUFACTURER'S CATHETER BECAME STUCK ON THE NON MANUFACTURER'S GUIDEWIRE. DURING REMOVAL THE MANUFACTURER'S CATHETER WAS RUN FOR A MOMENT INSIDE THE SHEATH BUT UNABLE TO RELEASE; THEREFORE, IT WAS REMOVED AS A SYSTEM. THE PROCEDURE WAS COMPLETED WITH A NEW SHEATH AND A NEW MANUFACTURER'S CATHETER. DURING THE RETURN PRODUCT EVALUATION, FOREIGN PLASTIC MATERIAL FROM THE NON MANUFACTURER'S SHEATH WAS OBSERVED ON THE CUTTER HEAD. NO PATIENT INJURY REPORTED. THIS PRODUCT PROBLEM IS BEING SUBMITTED AS CONCOMITANT USAGE DUE TO THE FOREIGN PLASTIC MATERIAL OBSERVED ON THE MANUFACTURER'S CATHETER. THERE IS POTENTIAL FOR HARM WITH RECURRENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12791780 ↗InjuryDec 29, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT A COOK GUIDEWIRE WAS USED AND 2CM OF THE COOK SPRING TIP WAS BROKEN OFF INSIDE THE PATIENT [DURING A PERIPHERAL ATHERECTOMY PROCEDURE UTILIZING THE MANUFACTURERS ATHERECTOMY DEVICE.] THEY DID NOT RETRIEVE THE SPRING-TIP. THROUGH X-RAY THEY CONFIRMED IT WAS IN A SIDE BRANCH, NOT FLOW LIMITING. THEY WERE ABLE TO COMPLETE THE CASE. THE PATIENT'S TREATMENT WAS COMPLETED BY THIS PROCEDURE WITH THE PATIENT DISCHARGED AS EXPECTED. VESSEL: LESION LOCATION WAS THE ENTIRE ANTERIOR TIBIAL ARTERY; 80-100% OCCLUDED; PLAQUE APPEARED TO BE CALIFIC; NO TORTUOSITY NOTED EXCEPT FOR THE TYPICAL BEND IN PROXIMAL ANTERIOR TIBIAL (AS PER ANATOMY.) OTHER DEVICES IN USE: COOK ANSEL 90CM SHEATH, COOK ROADRUNNER .014X300CM GUIDEWIRE. THIS EVENT IS BEING REPORTED BECAUSE AN ADVERSE EVENT OCCURRED (COOK ANSEL GUIDEWIRE TIP SEPARATION) WHILE THE MANUFACTURERS DEVICE WAS IN USE AS PART OF THE PROCEDURE. THIS WAS NOT A MALFUNCTION OF THE MANUFACTURERS ATHERECTOMY DEVICE.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 7155719 ↗MalfunctionFeb 3, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THIS CASE HAS BEEN INVESTIGATED IN ACCORDANCE WITH THE MANUFACTURERS POLICY. IT WAS REPORTED THAT DURING THE PROCEDURE WHILE REMOVING THE MANUFACTURERS DEVICE, OVER THE COOK WIRE, THE TIP OF THE WIRE BROKE OFF IN AN OCCLUDED PERONEAL ARTERY. THE PHYSICIAN ELECTED NOT TO ATTEMPT INTERVENTION TO REMOVE THE WIRE FRAGMENT AS IT WAS IN AN OCCLUDED ARTERY WITH NO ADDITIONAL CLINICAL SEQUELA. THE PHYSICIAN PERFORMED AN ADJUNCTIVE PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) TO COMPLETE THE PROCEDURE. THE PATIENT'S TREATMENT WAS COMPLETED BY THIS PROCEDURE WITH THE PATIENT DISCHARGED AS EXPECTED. VESSEL: SFA/POP AND TPT. OTHER DEVICES IN USE: COOK ROADRUNNER LOT# 7405229.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 6302675 ↗
Other Catheter, Peripheral, Atherectomy devices
- HawkOne™ H1-MCovidien LP · Catheter, peripheral, atherectomy1 recall367 reports
- JETSTREAM™ XC 112266-001Boston Scientific Corporation · Catheter, peripheral, atherectomy288 reports
- JETSTREAM™ XC 112264-001Boston Scientific Corporation · Catheter, peripheral, atherectomy262 reports
- SET Rotarex®S 6F 135cm (Straub Medical®) Version 1.0Straub Medical AG · Catheter, Peripheral, Atherectomy2 deaths206 reports
- SET Rotarex™S 6 F x 135 cm 80237Straub Medical AG · Catheter, Peripheral, Atherectomy1 recall79 reports
- HawkOne™ H1-SCovidien LP · Catheter, peripheral, atherectomy1 recall70 reports
- Turbo-Elite Laser Atherectomy Catheter 420-006Spectranetics Corporation · Catheter, Peripheral, Atherectomy2 recalls19 reports
- Turbo-Elite Laser Atherectomy Catheter 417-152Spectranetics Corporation · Catheter, Peripheral, Atherectomy2 recalls16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page