Phoenix 1.8mm x 149cm 5F Atherectomy System P18149KRecalls & reported problems
Volcano Atheromed, Inc. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00845225002725), received between Feb 4, 2025 and Aug 3, 2026 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Entrapment of Device” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Entrapment of Device5
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 3, 2026Entrapment of Device
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50124397 ↗MalfunctionApr 13, 2026Entrapment of Device
IT WAS REPORTED THAT A PHOENIX ATHERECTOMY CATHETER WAS USED FOR A THERAPEUTIC PERIPHERAL PROCEDURE IN A CTO AT THE DISTAL POPLITEAL. DURING USE, THE CATHETER WAS ADVANCED OVER A PHOENIX GUIDEWIRE TO THE SITE OF THE OCCLUSION, WHICH PERFORMED WELL BY FULLY REOPENING THE VESSEL. HOWEVER, AT THE DISTAL END OF THE OCCLUSION, THE GUIDEWIRE ROTATED DESPITE BEING SECURED TO THE TORQUER, AND THE CATHETER DRILL HEAD BORED INTO THE GUIDEWIRE AND BECAME JAMMED; THEREFORE, REMOVED AS A SYSTEM. UPON REMOVAL, IT WAS NOTED THAT A SMALL PIECE OF THE GUIDEWIRE HAD SEPARATED (MDR 9681477-2026-00052); UNABLE TO RETRIEVE DUE TO THE AREA NOT BEING ACCESSIBLE AND WAS NOT RELEVANT TO THE FOOT'S BLOOD SUPPLY. THE PROCEDURE WAS COMPLETED WITH A DRUG COATED BALLOON WITH NO PATIENT INJURY REPORTED. THIS PRODUCT PROBLEM IS BEING SUBMITTED BECAUSE THE PHOENIX CATHETER AND GUIDEWIRE WERE REMOVED AS A SYSTEM. THERE IS POTENTIAL FOR HARM IF IT WERE TO RECUR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24865586 ↗MalfunctionNov 12, 2025Entrapment of Device; Entrapment of Device
IT WAS REPORTED THAT A PHOENIX CATHETER WAS USED IN A MODERATELY CALCIFIED PERIPHERAL PROCEDURE. PRIOR TO USING THE CATHETER IN THE PERONEAL, IVUS WAS PERFORMED IN THE POSTERIOR TIBIAL WHERE IT WAS NOTICED THAT AN UNDERSIZED STENT WAS IN THE VESSEL, THUS DECIDED NOT TO USE THE CATHETER IN THAT AREA. THE PHOENIX CATHETER WAS TURNED ON IN WHAT WAS THOUGHT TO BE THE PERONEAL, BUT WAS MISTAKENLY IN THE TIBIAL PERONEAL TRUNK, WHEN A WEIRD SOUND WAS NOTED. THE BATTERY PACK WAS FLIPPED BUT NOTHING WAS HAPPENING. THE CATHETER WAS REMOVED OVER THE GUIDEWIRE, BUT THE CATHETER CLIPPED THE END OF THE STENT AND PULLED IT OUT. NO STENT REPLACEMENT WAS NEEDED SINCE THE VESSEL LOOKED GOOD. THE PROCEDURE WAS COMPLETED WITH A NEW CATHETER WITH NO PATIENT INJURY REPORTED. THIS PRODUCT PROBLEM IS BEING SUBMITTED BECAUSE THE PHOENIX CATHETER AND EXISTING STENT WERE REMOVED AS A SYSTEM, POTENTIAL FOR HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23536286 ↗MalfunctionAug 15, 2025Entrapment of Device; Entrapment of Device
IT WAS REPORTED THAT A PHOENIX CATHETER WAS USED IN A THERAPEUTIC PERIPHERAL PROCEDURE IN A SLIGHTLY CALCIFIED PROXIMAL SFA. DURING REMOVAL, THE CATHETER GOT STUCK ON A NON-PHILIPS GUIDEWIRE, AND BOTH WERE REMOVED AS A SYSTEM. THE PROCEDURE WAS COMPLETED WITH AN ANGIOPLASTY BALLOON WITH NO PATIENT INJURY REPORTED. THIS PRODUCT PROBLEM IS BEING SUBMITTED BECAUSE THE PHOENIX CATHETER AND CONCOMITANT DEVICE WERE REMOVED AS A SYSTEM; POTENTIAL FOR HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22821705 ↗MalfunctionFeb 4, 2025Entrapment of Device; Entrapment of Device
IT WAS REPORTED THAT A PHOENIX CATHETER WAS USED IN A THERAPEUTIC PERIPHERAL PROCEDURE. DURING REMOVAL, THE CATHETER GOT STUCK ON A NON-PHILIPS GUIDEWIRE, AND BOTH WERE REMOVED AS A SYSTEM. THE PROCEDURE WAS COMPLETED WITH THE PHOENIX CATHETER. NO PATIENT INJURY REPORTED. THIS PRODUCT PROBLEM IS BEING SUBMITTED BECAUSE THE PHOENIX CATHETER AND A NON-PHILIPS GUIDEWIRE WERE REMOVED AS A SYSTEM. THERE IS POTENTIAL FOR HARM IF IT WERE TO RECUR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21305404 ↗
Other Catheter, Peripheral, Atherectomy devices
- HawkOne™ H1-MCovidien LP · Catheter, peripheral, atherectomy1 recall367 reports
- JETSTREAM™ XC 112266-001Boston Scientific Corporation · Catheter, peripheral, atherectomy288 reports
- JETSTREAM™ XC 112264-001Boston Scientific Corporation · Catheter, peripheral, atherectomy262 reports
- SET Rotarex®S 6F 135cm (Straub Medical®) Version 1.0Straub Medical AG · Catheter, Peripheral, Atherectomy2 deaths206 reports
- SET Rotarex™S 6 F x 135 cm 80237Straub Medical AG · Catheter, Peripheral, Atherectomy1 recall79 reports
- HawkOne™ H1-SCovidien LP · Catheter, peripheral, atherectomy1 recall70 reports
- Turbo-Elite Laser Atherectomy Catheter 420-006Spectranetics Corporation · Catheter, Peripheral, Atherectomy2 recalls19 reports
- Turbo-Elite Laser Atherectomy Catheter 417-152Spectranetics Corporation · Catheter, Peripheral, Atherectomy2 recalls16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page