Streamline® MIS Spinal Fixation System 05-SCREW-INS-THRDRecalls & reported problems
Xtant Medical Holdings, Inc. · SCREW INSERTER, THREADED · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00846468050672), received between Mar 15, 2018 and Apr 17, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 17, 2018Break; Break
DURING THE FINAL LOCKING OF THE SET SCREW ON A POSTERIOR SPINAL FUSION SURGERY THE TIP OF THE SCREW DRIVER BROKE OFF INTO THE HEAD OF THE SET SCREW AND WAS LEFT IN THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7437765 ↗MalfunctionMar 15, 2018Break; Break
DURING A SPINAL SURGERY, THE HEX TIP PORTIONS OF TWO SCREW DRIVERS BROKE OFF IN THE SCREW HEADS AND WERE NOT ABLE TO BE REMOVED. THE SURGERY WAS COMPLETED SUCCESSFULLY AND WITH NO INJURY TO THE PATIENT. SINCE THE BROKEN TIPS WERE CONTAINED WITHIN THE SPINAL CONSTRUCT AND BENEATH THE LOCKED SPINAL ROD, THE SURGEON BELIEVES THAT THIS WILL HAVE NO NEGATIVE RESULTS ON THE CONSTRUCT OR THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7340951 ↗
Other SCREWDRIVER devices
- DELTA XTEND 2307-92-003Depuy (Ireland) · SCREWDRIVER751 reports
- EXPEDIUM 279712400Medos International Sàrl · SCREWDRIVER551 reports
- NA 314.467Synthes GmbH · SCREWDRIVER498 reports
- N/A 5584111Medtronic Sofamor Danek, Inc. · SCREWDRIVER492 reports
- QUICKSET 2274-47-000Depuy (Ireland) · SCREWDRIVER487 reports
- NA 03.130.010Synthes GmbH · SCREWDRIVER1 recall422 reports
- QUICKSET 2274-63-000Depuy (Ireland) · SCREWDRIVER404 reports
- EVOS 71175072Smith & Nephew, Inc. · SCREWDRIVER336 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page