CervAlign Anterior Cervical Plate System 66-DRIVER-SGRecalls & reported problems
Pioneer Surgical Technology, Inc. · Driver, Stab And Grab · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00846468088088), received between Jun 3, 2024 and Mar 7, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Material Fragmentation” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Material Fragmentation2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 7, 2025Material Fragmentation; Material Fragmentation
THE MANUFACTURER WAS MADE AWARE OF A PRODUCT COMPLAINT ON 2/20/2025. IT WAS REPORTED THAT THE DISTAL TIP OF A SYSTEM SCREWDRIVER WAS BROKEN WHEN TIGHTENING AN IMPLANT SCREW. THE FRACTURED TIP WAS RECOVERED, AND AN ALTERNATE AVAILABLE INSTRUMENT WAS UTILIZED TO SUCCESSFULLY COMPLETE THE PROCEDURE. THERE WAS NO KNOWN PATIENT COMPLICATIONS ASSOCIATED WITH THIS COMPLAINT. A RETURN AUTHORIZATION WAS ISSUED FOR RETURN OF THE COMPLAINT INSTRUMENT, WHICH WAS RECEIVED AT THE MANUFACTURER FOR ASSESSMENT ON 2/24/2025.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21553925 ↗MalfunctionJun 3, 2024Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT THE TIP OF A SYSTEM DRIVER WAS BROKEN WHILE BEING USED IN A SURGICAL PROCEDURE. THERE WERE NO KNOWN PATIENT COMPLICATIONS OR DELAY IN TREATMENT ASSOCIATED WITH THIS COMPLAINT. THE COMPLAINANT PROVIDED A PHOTO THAT IDENTIFIED THE INSTRUMENT UDI BUT DID NOT SHOW THE BROKEN PORTION OF THE SYSTEM DRIVER. IT IS UNCLEAR IF THE INSTRUMENT TORX TIP OR DISTAL SLEEVE WAS BROKEN. AN RMA# WAS ISSUED FOR RETURN OF THE COMPLAINT INSTRUMENT, WHICH WAS NOT RECEIVED AT THE MANUFACTURER FOR ASSESSMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19455980 ↗
Other SCREWDRIVER devices
- DELTA XTEND 2307-92-003Depuy (Ireland) · SCREWDRIVER751 reports
- EXPEDIUM 279712400Medos International Sàrl · SCREWDRIVER551 reports
- NA 314.467Synthes GmbH · SCREWDRIVER498 reports
- N/A 5584111Medtronic Sofamor Danek, Inc. · SCREWDRIVER492 reports
- QUICKSET 2274-47-000Depuy (Ireland) · SCREWDRIVER487 reports
- NA 03.130.010Synthes GmbH · SCREWDRIVER1 recall422 reports
- QUICKSET 2274-63-000Depuy (Ireland) · SCREWDRIVER404 reports
- EVOS 71175072Smith & Nephew, Inc. · SCREWDRIVER336 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page