Tornier Perform® Reversed Glenoid DWJ023Recalls & reported problems

Tornier, Inc. · Class 2 · Implant

All models of Tornier Perform Reversed Glenoid (41)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
16
Deaths reported
0
Injuries reported
16
Recalls naming it
0

Summary

The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 00846832090389), received between Jan 10, 2022 and Sep 29, 2026 — classified as 16 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 2 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem7
  • Device Dislodged or Dislocated5
  • Unstable3
  • Osseointegration Problem2
  • Biocompatibility1
  • Loss of Osseointegration1

Patient problems

  • Unspecified Infection5
  • Joint Laxity3
  • Subluxation3
  • Inadequate Osseointegration2
  • Joint Dislocation2
  • Loss of Range of Motion2
  • Discomfort1
  • Extraskeletal ossification1

Recent adverse event reports

The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.

  • InjurySep 29, 2026Unstable

    As reported: "Patients shoulder became unstable six months after initial RSA surgery so surgeon performed a revision surgery to exchange the 39mm Glenosphere and 45% reverse poly insert."

    Patient problems: Joint Laxity

    MAUDE report 50934359 ↗
  • InjuryMay 20, 2026Adverse Event Without Identified Device or Use Problem

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES OF MONTHLY REPORT OF (B)(6) 2026 DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2026, A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Unspecified Infection

    MAUDE report 25229450 ↗
  • InjuryFeb 16, 2026Adverse Event Without Identified Device or Use Problem

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2024. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2024 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Unspecified Infection

    MAUDE report 24342152 ↗
  • InjuryDec 10, 2025Unstable; Device Dislodged or Dislocated; Unstable; Device Dislodged or Dislocated

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025 A PATIENT REQUIRED REVISION SURGERY DUE TO INSTABILITY, DISLOCATION & SUBLUXATION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Joint Laxity; Subluxation

    MAUDE report 23768660 ↗
  • InjuryMay 26, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES OF THE SHOULDER JOINT REPLACEMENT. THE REPORT DETAILS ANALYSIS PROVIDED FOR REVISION PROCEDURES PERFORMED UNTIL (B)(6) 2025. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2025 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER.

    Patient problems: Unspecified Infection

    MAUDE report 22083417 ↗
  • InjuryNov 28, 2024Unstable; Device Dislodged or Dislocated; Unstable; Device Dislodged or Dislocated

    AS REPORTED: "SUBJECT (B)(6) SHOUT - TORNIER SHOULDER OUTCOMES STUDY. RECENTLY UNDERWENT REVISION REVERSE WITH AN ALLOGRAFT PROSTHESIS AND SUBSEQUENTLY HAD A DISLOCATION. ON (B)(6) 2022 : INSERT, TRAY AND GLENOSPHERE WERE REPLACED DURING REVISION SURGERY DUE TO INSTABILITY- DISLOCATION. INSERT: 39 DIA RETENTIVE +9MM/7.5C. TRAY: CENTERED +0MM. GLENOSPHERE: 39MM LATERALIZED (+3MM))".

    Patient problems: Joint Laxity; Subluxation

    MAUDE report 20804615 ↗
  • InjurySep 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN APRIL 2012 ¿ MAY 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2021 A PATIENT REQUIRED REVISION SURGERY DUE TO INFECTION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE: DEBRIDEMENT AND IMPLANT RETENTION (DAIR).

    Patient problems: Unspecified Infection

    MAUDE report 20144282 ↗
  • InjuryJul 18, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE PATIENT UNDERWENT A REVISION SURGERY DUE TO CONVERSION FROM AN ANATOMIC TO A REVERSE SHOULDER CONFIGURATION, DURING WHICH A GREATER TUBEROSITY FRACTURE OCCURRED. THE SURGEON PLANNED A TWO-STAGED REVISION: THE FIRST STAGE INVOLVED REMOVING ALL IMPLANTS AND PLACING A REVERSE GLENOID; THE SECOND STAGE INCLUDED REPLACING THE GLENOID SPHERE AND IMPLANTING THE HUMERAL STEM.

    Patient problems: Limb Fracture

    MAUDE report 19774564 ↗
  • InjuryMar 22, 2024Biocompatibility; Biocompatibility

    THE PATIENT REPORTED PAIN AND DECREASED FUNCTION, LEADING TO A REVISION SURGERY. THE REASON FOR THE REVISION SURGERY WAS LISTED AS HETEROTOPIC OSSIFICATION, SEVERE STIFFNESS, AND NICKEL METAL ALLERGY. COMPONENTS INCLUDING THE TRAY, INSERT, AND GLENOSPHERE WERE EXPLANTED, WHILE THE STEM, BASEPLATE, AND CENTRAL SCREW WERE RETAINED. THE RELATEDNESS TO THE STUDY DEVICE AND THE SURGICAL PROCEDURE WAS ASSESSED AS POSSIBLE.

    Patient problems: Extraskeletal ossification; Implant Pain; Loss of Range of Motion; Metal Related Pathology

    MAUDE report 18963882 ↗
  • InjuryFeb 29, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    THE MANUFACTURER RECEIVED A REPORT FROM THE NATIONAL JOINT REGISTRY THAT CONTAINS UNPUBLISHED COLLECTED DATA ON THE USAGE AND THE OUTCOMES WITH THE TORNIER SHOULDER SYSTEM. THE REPORT DETAILS ANALYSIS PROVIDED FOR PROCEDURES PERFORMED BETWEEN APRIL 2012 ¿ MAY 2022. DURING THE REVIEW OF THE REPORT, IT WAS IDENTIFIED THAT ON (B)(6) 2020 A PATIENT REQUIRED REVISION SURGERY DUE TO DISLOCATION/SUBLUXATION, WHICH WAS NOT PREVIOUSLY REPORTED TO THE MANUFACTURER. REVISION PROCEDURE TYPE: SINGLE STAGE REVISION.

    Patient problems: Joint Dislocation; Subluxation

    MAUDE report 18812567 ↗
  • InjuryFeb 26, 2024Loss of Osseointegration; Osseointegration Problem; Loss of Osseointegration; Osseointegration Problem

    IT WAS REPORTED THAT THE PATIENT REQUIRED REVISION SURGERY AFTER EXPERIENCING LOOSENING OF THE GLENOSPHERE. THE GLENOSPHERE WAS REPLACED SUCCESSFULLY AND WITH GOOD OUTCOME FOR THE PATIENT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 18783688 ↗
  • InjuryJan 30, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IN THE PHS STEMLESS IDE STUDY, A PARTICIPANT REPORTED STIFFNESS AND DISCOMFORT IN THE NECK AND LEFT HAND. DESPITE RECEIVING TREATMENTS LIKE MELOXICAM AND ORAL STEROIDS, THE SYMPTOMS PERSISTED. SEEKING A SECOND OPINION FROM A HAND SPECIALIST, THE PATIENT UNDERWENT A STEROID INJECTION IN THE LEFT RING AND LONG FINGERS. DISSATISFIED WITH THE PROGRESS AND CARE, THE PARTICIPANT WAS REFERRED TO ANOTHER HAND SURGEON FOR FURTHER EVALUATION, INCLUDING PENDING EMG AND CERVICAL MRI. THE PATIENT ATTRIBUTES THE SYMPTOMS TO A PREVIOUS SHOULDER SURGERY, EXPRESSING CERTAINTY THAT IT IS THE ROOT CAUSE.

    Patient problems: Discomfort; Loss of Range of Motion

    MAUDE report 18609104 ↗
  • InjurySep 6, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated

    DURING A REVISION SURGERY, LARGER GLENOSPHERE AND POLY IMPLANTS WERE USED TO ADDRESS CHRONIC DISLOCATION IN THE PATIENT'S SHOULDER JOINT. IT'S LIKELY THAT THE TEETH OF ONE OF THE INSTRUMENTS, SPECIFICALLY THE GLENOSPHERE REMOVAL TOOL, WERE BENT PRIOR TO THE SURGERY, AS THEY WERE OBSERVED TO BE SLIGHTLY BENT FROM THE OUTSET. THE GLENOSPHERE AND POLY IMPLANTS WERE TORNIER PRODUCTS. HOWEVER, IT'S IMPORTANT TO NOTE THAT THE REVISION SURGERY WAS NOT DUE TO FAULTY IMPLANTS BUT RATHER INSTABILITY ISSUES. THE SURGICAL PROCEDURE ENCOUNTERED DIFFICULTIES INITIALLY DUE TO THE DAMAGED INSTRUMENT BUT PROCEEDED SMOOTHLY AFTER SWITCHING TO ANOTHER SET OF INSTRUMENTS.

    Patient problems: Joint Dislocation

    MAUDE report 17692120 ↗
  • InjuryAug 23, 2023Osseointegration Problem; Osseointegration Problem

    THE TORNIER SHOULDER OUTCOMES STUDY'S PATIENT EXPERIENCED A REVISION SURGERY DUE TO ISSUES WITH LOOSENING/LYSIS. DURING THE PROCEDURE, A GLENOID SPHERE WAS REMOVED AND REPLACED WITH A REVERSED-LATERALIZED GLENOSPHERE THAT WAS 3MM LARGER (39MM). AN ADDITIONAL UPDATE REVEALED THAT THE TORNIER HRS ARS741701 WAS ALSO REMOVED DURING THE SURGERY.

    Patient problems: Inadequate Osseointegration; Osteolysis

    MAUDE report 17602969 ↗
  • InjuryNov 1, 2022Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED THAT THE PATIENT WAS REVISED AFTER PATIENT COMPLAINT AND NOTIFIED PHYSICIAN. RADIOGRAPHS WERE TAKEN AND THE PHYSICIAN STATED THE IMPLANT APPEARED TO HAVE DISASSOCIATED FROM BASEPLATE. PATIENT NOTICED A DIFFERENCE IN THE WAY HIS SHOULDER FELT AFTER 1 YEAR AFTER BEING IMPLANTED. RADIOGRAPHS ARE AVAILABLE PRE AND POST OPERATIVE, NO REMARKABLE CIRCUMSTANCES NOTED TO CONTRIBUTE TO THIS EVENT. PATIENT REQUIRED REVISION AFTER PHYSICIAN DOCUMENTED VIA RADIOGRAPHS THAT THE GLENOSPHERE APPEARED TO BECOME DISASSOCIATED FROM WELL-FIXED BASEPLATE. OTHER IMPLANTS NOTED FOR THE REVERSE SHOULDER ARTHROPLASTY WERE GLENOID BASEPLATE, X 2 SCREWS, HUMERAL CUP, POLY AND HUMERAL STEM. THE EXPLANTED IMPLANTS WERE REQUESTED TO BE RETURNED AT THE TIME OF THE REVISION SURGERY BUT HAVE NOT RECEIVED THESE BACK FROM HOSPITAL TO DATE.

    Patient problems: Failure of Implant

    MAUDE report 15712568 ↗
  • InjuryJan 10, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A REVISION SURGERY TWO YEARS AFTER PRIMARY STUDY SURGERY DUE TO INFECTION. THE STEM, TRAY AND INSERT WERE REMOVED, AS WELL AS REVERSED BASEPLATE AND GLENOSPHERE. FIRST STAGE OF A 2-STAGE SURGERY: REVISED TO ANTIBIOTIC CEMENT HEMI.

    Patient problems: Unspecified Infection

    MAUDE report 13212719 ↗

Other shoulder prosthesis, reverse configuration devices

All shoulder prosthesis, reverse configuration devices →