BioHorizons TIM7009Recalls & reported problems
Biohorizons Implant Systems, Inc · Tapered IM Implant 7mm X 9mm, Laser-Lok, RBT · Class 2 · Implant
Quick summary
This BioHorizons Tapered IM dental implant has 269 reports, with no deaths and 269 injuries. Most describe the implant failing to bond with the jawbone, and some describe the implant being removed soon after placement. The reports give little other detail about patients. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 272
- Deaths reported
- 0
- Injuries reported
- 272
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 272 adverse event reports that list this exact device (DI 00847236012465), received between Feb 15, 2024 and Sep 17, 2026 — classified as 272 injuries.
The most frequently reported specific device problem is “Failure to Osseointegrate” (174 reports).
1 other recall cover devices cleared under the same FDA submission (K182070, K223697); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate174
- Use of Device Problem108
- Loss of Osseointegration1
Patient problems
- Insufficient Information272
Recent adverse event reports
The 25 most recent of 272 reports, in the reporter's own words as published by the FDA.
InjurySep 17, 2026Failure to Osseointegrate
InjurySep 10, 2026Failure to Osseointegrate
InjurySep 10, 2026Use of Device Problem
Implant removed due to surgical consideration within 36 hours.
Patient problems: Insufficient Information
MAUDE report 50710966 ↗InjurySep 8, 2026Use of Device Problem
Patient problems: Insufficient Information
MAUDE report 50679408 ↗InjurySep 8, 2026Use of Device Problem
Implant removed due to surgical consideration within 36 hours.
Patient problems: Insufficient Information
MAUDE report 50669562 ↗InjuryAug 31, 2026Use of Device Problem
Implant removed due to surgical consideration within 36 hours.
Patient problems: Insufficient Information
MAUDE report 50522583 ↗InjuryAug 19, 2026Failure to Osseointegrate
InjuryAug 19, 2026Failure to Osseointegrate
InjuryAug 16, 2026Failure to Osseointegrate
InjuryJul 21, 2026Failure to Osseointegrate
InjuryJul 10, 2026Failure to Osseointegrate
InjuryJul 10, 2026Failure to Osseointegrate
InjuryJul 9, 2026Failure to Osseointegrate
InjuryJul 6, 2026Failure to Osseointegrate
InjuryJul 6, 2026Failure to Osseointegrate
InjuryJul 6, 2026Failure to Osseointegrate
InjuryJun 30, 2026Failure to Osseointegrate
InjuryJun 23, 2026Failure to Osseointegrate
InjuryJun 22, 2026Failure to Osseointegrate
InjuryJun 12, 2026Failure to Osseointegrate
InjuryJun 10, 2026Failure to Osseointegrate
InjuryJun 10, 2026Failure to Osseointegrate
InjuryJun 2, 2026Failure to Osseointegrate
InjuryJun 2, 2026Failure to Osseointegrate
InjuryMay 29, 2026Use of Device Problem
IMPLANT REMOVED DUE TO SURGICAL CONSIDERATION WITHIN 36 HOURS.
Patient problems: Insufficient Information
MAUDE report 25338144 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K182070, K223697. One submission often covers many models, so check the product and lot details in each record.
- Z-1111-2025 · Dec 6, 2024 · Open, ClassifiedTemporary Titanium Abutments
Other Implant, Endosseous, Root-Form devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.