Skip to content

BioHorizons BTA5212Recalls & reported problems

Biohorizons Implant Systems, Inc · 5.2mm x 12mm Tapered Pro Implant, Laser-Lok, RBT · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This Tapered Pro dental implant from BioHorizons is placed into the jawbone. The FDA database holds 540 reports for it, all of them injuries and none of them deaths. Most reports describe the implant failing to bond with the bone, and some describe implants removed soon after placement. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
537
Deaths reported
0
Injuries reported
537
Recalls naming it
0

Summary

The FDA's MAUDE database contains 537 adverse event reports that list this exact device (DI 00847236013820), received between Feb 15, 2024 and Sep 21, 2026 — classified as 537 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (381 reports).

2 other recalls cover devices cleared under the same FDA submission (K071638, K143022, K223697); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 10 reportsMar 2024: 29 reportsApr 2024: 14 reportsMay 2024: 22 reportsJun 2024: 29 reportsJul 2024: 22 reportsAug 2024: 9 reportsSep 2024: 15 reportsOct 2024: 22 reportsNov 2024: 17 reportsDec 2024: 35 reportsJan 2025: 9 reportsFeb 2025: 15 reportsMar 2025: 13 reportsApr 2025: 24 reportsMay 2025: 21 reportsJun 2025: 27 reportsJul 2025: 22 reportsAug 2025: 10 reportsSep 2025: 10 reportsOct 2025: 17 reportsNov 2025: 14 reportsDec 2025: 16 reportsJan 2026: 6 reportsFeb 2026: 23 reportsMar 2026: 20 reportsApr 2026: 18 reportsMay 2026: 14 reportsJun 2026: 7 reportsJul 2026: 11 reportsAug 2026: 10 reportsSep 2026: 6 reportsOct 2026: 0 reports20242025202635
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate381
  • Use of Device Problem168
  • Loss of Osseointegration5
  • Fracture3
  • Dull, Blunt1
  • Osseointegration Problem1
  • Packaging Problem1

Patient problems

  • Insufficient Information537

Recent adverse event reports

The 25 most recent of 537 reports, in the reporter's own words as published by the FDA.

  • InjurySep 21, 2026Failure to Osseointegrate

    Patient problems: Insufficient Information

    MAUDE report 50834941 ↗
  • InjurySep 11, 2026Failure to Osseointegrate

    Patient problems: Insufficient Information

    MAUDE report 50741686 ↗
  • InjurySep 10, 2026Use of Device Problem

    Patient problems: Insufficient Information

    MAUDE report 50721682 ↗
  • InjurySep 10, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 50710761 ↗
  • InjurySep 6, 2026Failure to Osseointegrate

    Patient problems: Insufficient Information

    MAUDE report 50637081 ↗
  • InjurySep 3, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 50581547 ↗
  • InjuryAug 25, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 50431803 ↗
  • InjuryAug 25, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 50431614 ↗
  • InjuryAug 21, 2026Use of Device Problem

    Implant removed due to surgical consideration within 36 hours.

    Patient problems: Insufficient Information

    MAUDE report 50375314 ↗
  • InjuryAug 16, 2026Use of Device Problem

    Implant removed due to surgical consideration within 36 hours.

    Patient problems: Insufficient Information

    MAUDE report 50268375 ↗
  • InjuryAug 14, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 50256399 ↗
  • InjuryAug 7, 2026Use of Device Problem

    Implant removed due to surgical consideration within 36 hours.

    Patient problems: Insufficient Information

    MAUDE report 50181755 ↗
  • InjuryAug 6, 2026Use of Device Problem

    Implant removed due to surgical consideration within 36 hours.

    Patient problems: Insufficient Information

    MAUDE report 50165592 ↗
  • InjuryAug 6, 2026Use of Device Problem

    Implant removed due to surgical consideration within 36 hours.

    Patient problems: Insufficient Information

    MAUDE report 50156591 ↗
  • InjuryAug 6, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 50156491 ↗
  • InjuryAug 5, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 50142562 ↗
  • InjuryJul 21, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 25891835 ↗
  • InjuryJul 12, 2026Use of Device Problem

    IMPLANT REMOVED DUE TO SURGICAL CONSIDERATION WITHIN 36 HOURS.

    Patient problems: Insufficient Information

    MAUDE report 25791622 ↗
  • InjuryJul 10, 2026Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE.

    Patient problems: Insufficient Information

    MAUDE report 25781386 ↗
  • InjuryJul 10, 2026Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE.

    Patient problems: Insufficient Information

    MAUDE report 25777666 ↗
  • InjuryJul 7, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 25735021 ↗
  • InjuryJul 7, 2026Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE

    Patient problems: Insufficient Information

    MAUDE report 25734987 ↗
  • InjuryJul 6, 2026Use of Device Problem; Failure to Osseointegrate

    IMPLANT REMOVED DUE TO SURGICAL CONSIDERATION WITHIN 36 HOURS.

    Patient problems: Insufficient Information

    MAUDE report 25717823 ↗
  • InjuryJul 6, 2026Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE.

    Patient problems: Insufficient Information

    MAUDE report 25717770 ↗
  • InjuryJul 6, 2026Failure to Osseointegrate

    Implant failed to osseointegrate.

    Patient problems: Insufficient Information

    MAUDE report 25717219 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K071638, K143022, K223697. One submission often covers many models, so check the product and lot details in each record.

  • Z-1111-2025 · Dec 6, 2024 · Open, Classified
    Temporary Titanium Abutments
  • Z-1605-2015 · Apr 16, 2015 · Terminated
    Tapered HD Upgrade Set, REF TSKHDUS, Non-Sterile, Rx Only, Product Usage Usage: Surgical instruments used in preparation for dental implant placement

Other Implant, Endosseous, Root-Form devices

All Implant, Endosseous, Root-Form devices →

Sources and updates