Skip to content

BioHorizons CTR5207Recalls & reported problems

Biohorizons Implant Systems, Inc · Tapered Short Conical Implant, 5.2 x 7.5mm, RBT · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
11
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 00847236024444), received between Mar 17, 2025 and Sep 10, 2026 — classified as 11 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 3 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 2 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate6
  • Use of Device Problem5

Patient problems

  • Insufficient Information11

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • InjurySep 10, 2026Use of Device Problem

    Implant removed due to surgical consideration within 36 hours.

    Patient problems: Insufficient Information

    MAUDE report 50721811 ↗
  • InjurySep 1, 2026Failure to Osseointegrate

    Patient problems: Insufficient Information

    MAUDE report 50539908 ↗
  • InjuryApr 1, 2026Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE.

    Patient problems: Insufficient Information

    MAUDE report 24755930 ↗
  • InjuryMar 18, 2026Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE.

    Patient problems: Insufficient Information

    MAUDE report 24628153 ↗
  • InjuryFeb 25, 2026Use of Device Problem

    IMPLANT REMOVED DUE TO SURGICAL CONSIDERATION WITHIN 36 HOURS.

    Patient problems: Insufficient Information

    MAUDE report 24446302 ↗
  • InjuryDec 22, 2025Use of Device Problem; Use of Device Problem

    IMPLANT REMOVED DUE TO SURGICAL CONSIDERATION WITHIN 36 HOURS.

    Patient problems: Insufficient Information

    MAUDE report 23863664 ↗
  • InjuryDec 10, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE.

    Patient problems: Insufficient Information

    MAUDE report 23774058 ↗
  • InjuryDec 8, 2025Use of Device Problem; Use of Device Problem

    IMPLANT REMOVED DUE TO SURGICAL CONSIDERATION WITHIN 36 HOURS.

    Patient problems: Insufficient Information

    MAUDE report 23751936 ↗
  • InjuryNov 17, 2025Use of Device Problem; Use of Device Problem

    IMPLANT REMOVED DUE TO SURGICAL CONSIDERATION WITHIN 36 HOURS.

    Patient problems: Insufficient Information

    MAUDE report 23568521 ↗
  • InjurySep 3, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE.

    Patient problems: Insufficient Information

    MAUDE report 22950748 ↗
  • InjuryMar 17, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED TO OSSEOINTEGRATE.

    Patient problems: Insufficient Information

    MAUDE report 21625981 ↗

Other Implant, Endosseous, Root-Form devices

All Implant, Endosseous, Root-Form devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page