PipelineTM Vantage Embolization Device with Shield TechnologyTM PED3-027-500-40Recalls & reported problems
Micro Therapeutics, Inc. · STENT PED3-027-500-40 V03 VANTAGE · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00847536036963), received between Feb 26, 2025 and Feb 26, 2025 — classified as 1 death.
The most frequently reported specific device problem is “Activation Failure” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
11 other recalls cover devices cleared under the same FDA submission (P100018); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- Jan 30, 2025Class IOpen, Classified
Use of embolization device with diameters greater-than-or-equal-to 4mm may lead to incomplete wall apposition and/or braid deformation (fish-mouthing/braid narrowing/braid collapse) noted during procedure and post-procedure, typically noted at 6-12 month imaging follow-up, potentially can lead to thrombosis and/or serious adverse events. Higher risk in females less-than-or-equal-to 45 years of age
Z-1245-2025 · Root cause: Device Design · Recall details · FDA record ↗
Most reported problems
Device problems
- Activation Failure1
- Activation, Positioning or Separation Problem1
- Collapse1
Patient problems
- Obstruction/Occlusion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathFeb 26, 2025Collapse; Activation, Positioning or Separation Problem; Activation Failure; Collapse; Activation, Positioning or Separation Problem; Activation Failure
ADDITIONAL INFORMATION RECEIVED REPORTED THE PHYSICIAN DID NOT FEEL THAT THE COMPLICATION WAS RELATED TO THE PIPELINE VANTAGE DEVICE. INSTEAD, THE PHYSICIAN FELT LIKE THE PATIENT WAS ABLE TO LIVE FOR ADDITIONAL TIME BECAUSE OF THE PROCEDURE THAT WAS PERFORMED. THE PATIENT HAD UNDERGONE TREATMENT OF A FUSIFORM DISSECTING GIANT VERTEBRAL ARTERY ANEURYSM THAT WAS VERY CHALLENGING TO TREAT WHICH WAS KNOWN OFF-LABEL USE OF THE PIPELINE VANTAGE. THE IMPLANTATION OF THE PIPELINE WENT EVEN BETTER THAN EXPECTED, WITH ONLY MINOR CHALLENGES. THE PATIENT'S CONDITION IMPROVED OVER TIME POST-OPERATIVELY, HOWEVER, AT 6 MONTH FOLLOW UP THE PATIENT REPORTED SYMPTOMS AND UPON ANGIOGRAPHIC IMAGING, THROMBOSIS AROUND THE IMPLANT AND NARROWING OF THE DEVICES WAS IDENTIFIED. THE PATIENT EXPIRED AROUND 9 MONTHS POST-IMPLANT. THE SOURCE OF THE IN-STENT STENOSIS WAS UNCLEAR BUT THE PHYSICIAN DID NOT ATTRIBUTE IT TO THE PIPELINE AS IT WAS NOTED THE PATIENT HAD OTHER CONDITIONS, AND THE PHYSICIAN CONSIDERED IT MORE LIKELY THAT THE PIPELINE DEVICE CAPTURED SOME THROMBUS, RATHER THAN GENERATING IT. THE PHYSICIAN EMPHASIZED MULTIPLE TIMES THAT THE PATIENT DEATH WAS, ON THEIR PART, NOT CONSIDERED TO BE RELATED T
Patient problems: Obstruction/Occlusion
MAUDE report 21472459 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P100018. One submission often covers many models, so check the product and lot details in each record.
- Z-1246-2025 · Jan 30, 2025 · Open, ClassifiedMedtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-021-350-16, PED3-021-250-14, PED3-021-350-20, PED3-021-250-20, PED3-021-300-16, PED3-021-300-20, PE
- Z-2403-2021 · Jul 13, 2021 · Open, ClassifiedEV3 Pipeline Flex Embolization Device with Flex Shield Technology
- Z-2402-2021 · Jul 13, 2021 · Open, ClassifiedPipeline Flex Embolization Device
- Z-1527-2020 · Feb 14, 2020 · Terminatedev3 Pipeline Flex Embolization Device. For neurological endovascular use.
- Z-0310-2017 · Oct 5, 2016 · TerminatedX-Celerator Hydrophilic Exchange Guidewire Catalog No. 103-0601-300 103-0601-350V10 103-0602-350V06 103-0601-300V01 103-0602-300 103-0602-350V09 103-0601-300V02 103-0602-300V01 10
- Z-0308-2017 · Oct 5, 2016 · TerminatedAlligator Retrieval Device The device is intended for use in the peripheral and neurovasculature for foreign body removal. Catalog No. FA-88810-20V04 FA-88810-20V06 FA-88810-30V04
- Z-0307-2017 · Oct 5, 2016 · TerminatedPipeline Embolization Device (Pipeline Classic) The device is indicated for the endovascular treatment of adults (22 year of age or older) with large or giant widenecked intracrani
- Z-0309-2017 · Oct 5, 2016 · TerminatedMarathon Flow Directed Micro Catheter, UltraFlow HPC Flow Directed Micro Catheter Marathon Flow: The device is intended to access periphera and neurovasculature for the controlled
- Z-0120-2016 · Sep 4, 2015 · Terminated-Pipeline Embolization Device -Pipeline Flex Embolization Device The Pipeline and Pipeline Flex Embolization Devices consist of a permanent implant combined with a guidewire based
- Z-1453-2014 · Apr 1, 2014 · TerminatedPipeline Embolization Device (PED). Used endovascular treatment of adults with intracranial aneurysms in the internal carotid artery.
- Z-2045-2013 · Jul 19, 2013 · TerminatedPipeline Embolization Device (PED) The Pipeline Embolization Device is indicated for the endovascular treatment of adults (22 years of age and older) with large or giant wide-neck
Other Intracranial aneurysm flow diverter devices
- Pipeline TM Flex Embolization Device with Shield Technology TM PED2-300-12Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter2 recalls1 report
- PIPELINE PED-500-20Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall31 reports
- PIPELINE PED-500-35Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death29 reports
- PIPELINE PED-500-16Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall2 deaths27 reports
- PIPELINE PED-500-25Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death23 reports
- PIPELINE PED-500-30Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall21 reports
- PIPELINE PED-450-25Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall20 reports
- PIPELINE PED-475-30Micro Therapeutics, Inc. · Intracranial aneurysm flow diverter1 recall1 death19 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page