Skip to content

RESTORIS 180515Recalls & reported problems

Mako Surgical Corp. · MCK Femoral Component · Class 2 · Implant

All models of RESTORIS (74)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00848486000646), received between Jun 22, 2020 and Nov 9, 2020 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).

5 other recalls cover devices cleared under the same FDA submission (K082172, K090763, K150307, K220930, K242831); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Device Difficult to Setup or Prepare1
  • Insufficient Device Problem Information1
  • Migration1

Patient problems

  • Injury1
  • Joint Dislocation1
  • No Clinical Signs, Symptoms or Conditions1
  • Pain1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 9, 2020Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare

    DURING A MEDIAL PARTIAL KNEE MAKO PROCEDURE PERFORM BY THE SURGEON, HE COULD NOT GET THE POLYETHYLENE INSERT TO LOCK IN THE TIBIAL BASEPLATE POSTERIORLY. THE TRIAL BASEPLATE AND TRIAL POLY WAS ABLE TO FIT WITH LITTLE DIFFICULTY DURING THE TRIALING STAGE, HOWEVER THE FINAL IMPLANT POLY WOULD NOT LOCK IN TO THE FINAL BASEPLATE MECHANISM DESPITE THE SURGEONS EFFORTS. FOUR DIFFERENT POLYETHYLENE INSERTS WHERE USED WITH THE SAME OUTCOME. ULTIMATELY THE SURGEON MADE THE DECISION TO COMPLETE THE CASE WITHOUT ACHIEVING COMPLETE LOCKING OF THE INSERT POSTERIORLY ¿ IT ACHIEVED LOCKING ANTERIORLY ON EACH OCCASION. 1H DELAY: UPDATE: TOURNIQUET WAS CONTINUED TO BE USED DURING THE DELAY BUT WAS TURNED OFF AT A TOURNIQUET TIME OF TWO HOURS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10812270 ↗
  • InjuryJun 22, 2020Insufficient Device Problem Information; Migration; Insufficient Device Problem Information; Migration

    IT WAS REPORTED THAT THE PATIENT'S RIGHT MAKO PARTIAL KNEE WAS REVISED DUE TO MEDIAL SUBSIDENCE OF THE FEMORAL COMPONENT, SUBSIDENCE OF THE TIBIAL COMPONENT, AND EXTREME POLY WEAR. SURGEON STATED THE OPINION THAT POLY WEAR/ DEBRIS WAS A CAUSE OR CONTRIBUTOR FOR FEMORAL SUBSIDENCE. PATIENT WAS REVISED TO A TOTAL KNEE. REP PROVIDED THE ORIGINAL USAGE REPORT AND EXPLANT PICTURES. THE DEVICES ARE ALLEGEDLY AVAILABLE FOR RETURN, OTHERWISE THE REP CONFIRMED THAT NO FURTHER INFORMATION WILL BE RELEASED.

    Patient problems: Injury; Joint Dislocation; Pain

    MAUDE report 10181638 ↗

FDA clearance and classification

Cleared through 510(k) K242831 on Dec 4, 2024 (decision: Substantially Equivalent). Submitted by Howmedica Osteonics Corp., Dba Stryker Orthopaedics as “Triathlon Knee System; Triathlon Pro Posterior Stabilized Femoral Components; Triathlon Tritanium Tibial Baseplate; Triathlon Low Profile Tibial Tray; Triathlon Metal Backed Patella; Triathlon Partial Knee System; Avon Patello-femoral Joint Prosthesis; Restoris Multi-Compartmental Knee System”. The FDA review took 76 days. FDA record ↗

Cleared through 510(k) K220930 on Jun 2, 2022 (decision: Substantially Equivalent). Submitted by Mako Surgical Corp. as “Restoris Multi-Compartmental Knee System”. The FDA review took 63 days. FDA record ↗

Cleared through Special 510(k) K150307 on Mar 10, 2015 (decision: Substantially Equivalent). Submitted by Mako Surgical Corp. as “RESTORIS Multicompartmental Knee System”. The FDA review took 29 days. FDA record ↗

…and 2 more FDA submissions listed for this device.

The FDA regulates product code HRY (prosthesis, knee, femorotibial, semi-constrained, cemented, metal/polymer) under 21 CFR 888.3530 as a Class II device. 21 CFR 888.3530 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K082172, K090763, K150307, K220930, K242831. One submission often covers many models, so check the product and lot details in each record.

  • Z-1385-2023 · Mar 10, 2023 · Open, Classified
    stryker MAKO RESTORIS MCK BASEPLATE TRIAL (SIZE 5 RM/LL), REF 170615, intended for use in a Partial Knee Arthroplasty surgical procedure
  • Z-1386-2023 · Mar 10, 2023 · Open, Classified
    stryker MAKO RESTORIS MCK BASEPLATE TRIAL (SIZE 6 RM/LL), REF 170616, intended for use in a Partial Knee Arthroplasty surgical procedure
  • Z-2051-2018 · Jan 19, 2018 · Terminated
    Restoris MCK Onlay Insert Extractor.
  • Z-1031-2016 · Jan 15, 2016 · Terminated
    Restoris Multicompartmental Knee (MCK) System RESTORIS MCK is indicated for single or multi-compartmental knee replacement used in conjunction with RIO.
  • Z-1132-2014 · Jan 9, 2014 · Terminated
    Restoris Multicompartmental Knee (MCK) System is an implant system designed to be used with MAKO's Robotic Arm Interactive Orthopedic System (RIO). It is composed of a unicompartme

Common questions about the RESTORIS 180515

Has the RESTORIS 180515 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00848486000646), based on the FDA recall file dated Nov 27, 2026. However, 5 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.

What problems have been reported with the RESTORIS 180515?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Jun 22, 2020 and Nov 9, 2020. In those reports, the most common specific device problems are “Device Difficult to Setup or Prepare” (1) and “Migration” (1); the most common patient problems are “Injury” (1), “Joint Dislocation” (1) and “Pain” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the RESTORIS 180515?

None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the RESTORIS 180515 FDA approved?

It was cleared through 510(k) K082172 on Nov 28, 2008; its record lists 5 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the RESTORIS 180515 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the RESTORIS 180515, and is it still sold?

The FDA's device database lists Mako Surgical Corp. as the company responsible for it (brand RESTORIS, model 180515). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER devices

All PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page