CANCELLOUS LOCKING SCREW, FULLY THREADED 4.0mm x 40mm 8124-040Recalls & reported problems

Advanced Orthopaedic Solutions, Inc. · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00848665033632), received between Nov 26, 2024 and Jul 24, 2025 — classified as 4 injuries.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 2 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Patient Device Interaction Problem1

Patient problems

  • Failure of Implant3
  • Nonunion/Delayed-union Bone Fracture1
  • Pain1
  • Unspecified Infection1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 24, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    ON (B)(6) 2025, A PATIENT'S LEGAL REPRESENTATIVE REPORTED VIA EMAIL THAT THE PATIENT UNDERWENT OPEN REDUCTION AND INTERNAL FIXATION OF A COMMINUTED FRACTURE OF THE LEFT HUMERAL NECK ON (B)(6) 2024. FOLLOWING THE PROCEDURE, THE PATIENT EXPERIENCED ONGOING COMPLICATIONS, INCLUDING PERSISTENT PAIN, NONUNION OF THE FRACTURE, AND SIGNIFICANT DISCOMFORT WITH ANY MOVEMENT OF THE LEFT SHOULDER. ON (B)(6) 2024, THE PATIENT WAS INFORMED THAT A TARGETER/DRILL GUIDE HAD BEEN INADVERTENTLY RETAINED FROM THE INITIAL PROCEDURE. A REVISION SURGERY WAS PERFORMED ON (B)(6) 2024 TO REMOVE THE RETAINED INSTRUMENT, DEBRIDE THE INFECTED AREA, AND REPLACE THE SURGICAL HARDWARE. ADDITIONAL INFORMATION RECEIVED ON 7/2/2025: DURING THE REVISION SURGERY ON (B)(6) 2024, THE FOLLOWING COMPONENTS WERE REMOVED: ONE 3022-005 PROXIMAL HUMERAL PLATE; TWO 8110-032 CORTICAL SCREWS; TWO 8110-035 CORTICAL SCREWS; ONE 8110-040 CORTICAL SCREW; ONE 8110-045 CORTICAL SCREW; ONE 8124-040 FULLY THREADED CANCELLOUS LOCKING SCREW; ONE 8124-044 FULLY THREADED CANCELLOUS LOCKING SCREW; THREE 8124-046 FULLY THREADED CANCELLOUS LOCKING SCREWS; TWO 8124-048 FULLY THREADED CANCELLOUS LOCKING SCREWS; AND ONE 8124-050 FULLY THREADED C

    Patient problems: Nonunion/Delayed-union Bone Fracture; Pain; Unspecified Infection

    MAUDE report 22585829 ↗
  • InjuryDec 12, 2024Break; Break

    ON 10/29/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT A 3024-01 11-HOLE LEFT ALPHA PLATE BROKE POSTOPERATIVELY THROUGH THE OBLONG HOLE IN THE FIRST BEND OF THE PLATE. ON (B)(6) 2024, THE PATIENT WAS IMPLANTED WITH THE PLATE, AND REVISION SURGERY IS STILL TO BE DETERMINED. PER THE SALES REPRESENTATIVE, THE PATIENT DID NOT REPORT ANY FALLS OR INJURIES. NO ADDITIONAL INFORMATION HAS BEEN REPORTED. ADDITIONAL INFORMATION RECEIVED ON 11/13/2024: DURING THE INITIAL SURGERY ON (B)(6) 2024, A 3024-01 11-HOLE LEFT ALPHA PLATE, TWO 8110-026 CORTICAL BONE SCREW, AN 8110-028 CORTICAL BONE SCREW, THREE 8110-030 CORTICAL BONE SCREWS, AN 8114-024 DOUBLE LEAD LOCK CORTICAL SCREW, AN 8114-026 DOUBLE LEAD LOCK CORTICAL SCREW, AN 8114-028 DOUBLE LEAD LOCK CORTICAL SCREW, AN 8114-030 DOUBLE LEAD LOCK CORTICAL SCREW, AN 8124-028 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-032 CANCELLOUS LOCKING SCREW, FULLY THREADED, AN 8124-038 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-040 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-046 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-048 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-050 FULLY THREADED CANCELLOUS LOCKING SCREW, AN

    Patient problems: Failure of Implant

    MAUDE report 20914883 ↗
  • InjuryNov 27, 2024Break; Break

    ON 10/29/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT A 3024-016 16-HOLE LEFT ALPHA PLATE BROKE POSTOPERATIVELY THROUGH THE OBLONG HOLE IN THE FIRST BEND OF THE PLATE. ON (B)(6) 2024, THE PATIENT WAS IMPLANTED WITH THE PLATE, AND ON (B)(6) 2024, THE PLATE WAS REMOVED. PER THE SALES REPRESENTATIVE, THE PATIENT DID NOT REPORT ANY FALLS OR INJURIES. NO ADDITIONAL INFORMATION HAS BEEN REPORTED. ADDITIONAL INFORMATION RECEIVED ON 11/13/2024: THE CORRECT ORIGINAL SURGERY DATE IS 2/20/2024. THE PATIENT WAS IMPLANTED WITH THE 3024-016 16-HOLE LEFT ALPHA PLATE, AN 8110-026 CORTICAL BONE SCREW, TWO 8110-028 CORTICAL BONE SCREWS, FOUR 8114-026 DOUBLE LEAD LOCK CORTICAL SCREW, AN 8114-036 DOUBLE LEAD LOCK CORTICAL SCREW, AN 8124-030 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-032 FULLY THREADED CANCELLOUS LOCKING SCREW, TWO 8124-036 FULLY THREADED CANCELLOUS LOCKING SCREW, TWO 8124-040 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-042 FULLY THREADED CANCELLOUS LOCKING SCREW, TWO AR-7268T TIGERTAPE CERCLAGE WITH FIBERLINK SHUTTLE SUTURE, AND AN ABS-2010-10 ALLOSYNC PURE. DURING THE REVISION SURGERY, ALL THE HARDWARE WAS REMOVED. THE REVISION SURGERY WAS COMPLETED USING

    Patient problems: Failure of Implant

    MAUDE report 20791088 ↗
  • InjuryNov 26, 2024Break; Break

    ON 10/29/2024, IT WAS REPORTED BY A SALES REPRESENTATIVE VIA EMAIL THAT A 3024-016 16-HOLE LEFT ALPHA PLATE BROKE POSTOPERATIVELY THROUGH THE OBLONG HOLE IN THE FIRST BEND OF THE PLATE. ON 2/2/2024, THE PATIENT WAS IMPLANTED WITH THE PLATE, AND ON (B)(6) 2024, THE PLATE WAS REMOVED. PER THE SALES REPRESENTATIVE, THE PATIENT DID NOT REPORT ANY FALLS OR INJURIES. NO ADDITIONAL INFORMATION HAS BEEN REPORTED. ADDITIONAL INFORMATION RECEIVED ON 11/13/2024: THE CORRECT ORIGINAL SURGERY DATE IS (B)(6) 2024. THE PATIENT WAS IMPLANTED WITH THE (B)(6); 16-HOLE LEFT ALPHA PLATE, AN 8110-026 CORTICAL BONE SCREW, TWO 8110-028 CORTICAL BONE SCREWS, FOUR 8114-026 DOUBLE LEAD LOCK CORTICAL SCREW, AN 8114-036 DOUBLE LEAD LOCK CORTICAL SCREW, AN 8124-030 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-032 FULLY THREADED CANCELLOUS LOCKING SCREW, TWO 8124-036 FULLY THREADED CANCELLOUS LOCKING SCREW, TWO 8124-040 FULLY THREADED CANCELLOUS LOCKING SCREW, AN 8124-042 FULLY THREADED CANCELLOUS LOCKING SCREW, TWO AR-7268T TIGERTAPE CERCLAGE WITH FIBERLINK SHUTTLE SUTURE, AND AN ABS-2010-10 ALLOSYNC PURE. DURING THE REVISION SURGERY, ALL THE HARDWARE WAS REMOVED. THE REVISION SURGERY WAS COMPLETED USING A

    Patient problems: Failure of Implant

    MAUDE report 20788668 ↗

Other Appliance, Fixation, Nail/Blade/Plate Combination, Single Component devices

All Appliance, Fixation, Nail/Blade/Plate Combination, Single Component devices →