Skip to content

Sharpoint 62-2450GRecalls & reported problems

Surgical Specialties México, S. de R.L. de C.V. · 2.4 mm CC3D+ Slit, Angled, Advanced Double Bevel · Class 1

All models of Sharpoint (5)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00848782044399), received between Sep 24, 2024 and Sep 24, 2024 — classified as 1 malfunction.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Appropriate Device Problem Term/Code Not Available1

Patient problems

  • Laceration(s)1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 24, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED ON AUGUST 30, 2024 THAT THE KNIFE DID NOT PERFORM AS EXPECTED DURING THE INCISION LEADING TO THE WOUND NOT SEALING PROPERLY AND SUTURES WERE ADDED AFTER THE INCISION. NO ADDITIONAL INJURIES REPORTED; HOWEVER, THE FAILURE RESULTED IN A SIGNIFICANT PROCEDURAL DELAY AS SURGICAL INTERVENTION WAS REQUIRED.

    Patient problems: Laceration(s)

    MAUDE report 20292443 ↗

FDA clearance and classification

The FDA regulates product code HNN (knife, ophthalmic) under 21 CFR 886.4350 as a Class I device. 21 CFR 886.4350 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Sharpoint 62-2450G

Has the Sharpoint 62-2450G been recalled?

No FDA recall record in our data names this exact device identifier (DI 00848782044399), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Sharpoint 62-2450G?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 24, 2024. That report lists patient problem “Laceration(s)” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Sharpoint 62-2450G?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Sharpoint 62-2450G FDA approved?

Devices of this type (product code HNN) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Surgical Specialties México, S. de R.L. de C.V.

Who makes the Sharpoint 62-2450G, and is it still sold?

The FDA's device database lists Surgical Specialties México, S. de R.L. de C.V. as the company responsible for it (brand Sharpoint, model 62-2450G). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Knife, ophthalmic devices

All Knife, ophthalmic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page