AutoPulse®Resuscitation System 100 (REF 8700-0730-02)Recalls & reported problems

Zoll Circulation, Inc. · The AutoPulse System consists of 4 primary components, a reusable Platform, a single use chest compression assembly (LifeBand), a rechargeable battery, and a battery charger. · Class 2

All models of AutoPulseResuscitation System (46)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00849111000550), received between Jun 15, 2016 and Mar 12, 2022 — classified as 1 injury, 4 malfunctions.

The most frequently reported specific device problem is “Use of Device Problem” (2 reports).

1 other recall cover devices cleared under the same FDA submission (K112998); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Use of Device Problem2
  • Visual Prompts will not Clear2
  • Adverse Event Without Identified Device or Use Problem1
  • Device Stops Intermittently1

Patient problems

  • No Known Impact Or Consequence To Patient2
  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1
  • No Patient Involvement1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 12, 2022Use of Device Problem; Use of Device Problem

    THE AUTOPULSE PLATFORM (SN UNKNOWN) WAS USED TO RESUSCITATE A PATIENT IN CARDIAC ARREST. THE USER INSTALLED THE NEW LIFEBAND (LOT# UNKNOWN) TO USE WITH THE PLATFORM, HOWEVER, THE PLATFORM COULD NOT MAKE COMPRESSIONS. THE CREW REVERTED TO MANUAL CPR FOR THE REST OF THE CALL. NO CONSEQUENCES OR IMPACT TO THE PATIENT. UPON RETURNING TO THE EMS CENTER, THE CREW NOTICED THAT THE LIFEBAND BAND CLIP THAT SNAPS INTO THE AUTOPULSE PLATFORM WAS BROKEN. PLEASE SEE THE FOLLOWING RELATED MFR REPORT: MFR #3010617000-2022-00249 FOR THE AUTOPULSE LIFEBAND.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13749163 ↗
  • MalfunctionApr 11, 2019Use of Device Problem; Visual Prompts will not Clear; Use of Device Problem; Visual Prompts will not Clear

    DURING PATIENT USE, THE AUTOPULSE PLATFORM (SN (B)(4)) STOPPED COMPRESSIONS AFTER AN UNKNOWN PERIOD OF TIME AND DISPLAYED UNKNOWN USER ADVISORY (UA) ERROR MESSAGE. THE USER WAS UNABLE TO CLEAR THE ERROR MESSAGE. THE PLATFORM WAS CHECKED BY (B)(4) TECHNICIAN. DURING TESTING AT (B)(4), THE AUTOPULSE PLATFORM STOPPED COMPRESSIONS AFTER PERFORMING COMPRESSIONS FOR ABOUT 8 MINUTES AND DISPLAYED UA45 (NOT AT "HOME" POSITION AFTER POWER-ON/RESTART) ERROR MESSAGE. THE USER EXPERIENCED DIFFICULTY IN REMOVING THE LIFEBAND FROM THE PLATFORM AND THE SHAFT WAS VERY HEAVY TO ROTATE MANUALLY. AFTER RE-POSITIONING THE LIFEBAND TO THE HOME POSITION, THE PLATFORM WAS RESTARTED. NO KNOWN IMPACT OR CONSEQUENCE TO PATIENT INFORMATION WAS PROVIDED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8506336 ↗
  • MalfunctionSep 7, 2018Visual Prompts will not Clear; Visual Prompts will not Clear

    AS REPORTED, DURING SHIFT CHECK, THE USER'S AUTOPULSE PLATFORM (B)(4) DISPLAYED USER ADVISORY - UA07 (DISCREPANCY BETWEEN LOAD 1 AND LOAD 2 TOO LARGE) ERROR MESSAGE. THE USER WAS UNABLE TO CLEAR THE ADVISORY. NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 7857550 ↗
  • MalfunctionAug 29, 2016Device Stops Intermittently; Device Stops Intermittently

    THE BIOMED REPORTED THAT THE AUTOPULSE PLATFORM (S/N: (B)(4)) STOPPED COMPRESSION AFTER 5 CYCLES. NO ERROR CODES/MESSAGES WERE OBSERVED. NO FURTHER INFORMATION WAS PROVIDED AND IT IS NOT KNOWN IF THERE WAS PATIENT INVOLVEMENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 5912741 ↗
  • InjuryJun 15, 2016Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2016, A (B)(6) WOMAN, WAS BEING SEEN IN THE EMERGENCY ROOM FOR THORACIC PAIN. IT IS UNKNOWN IF MANUAL CPR WAS PERFORMED BY A BYSTANDER PRIOR TO THE RESCUE TEAM ARRIVING. MANUAL CPR WAS PERFORMED BY THE RESCUE TEAM. IT IS UNKNOWN HOW LONG MANUAL CPR WAS PERFORMED. IN THE EMERGENCY ROOM (ER), THE PATIENT WENT INTO CARDIAC ARREST FOR VF (VENTRICULAR FIBRILLATION) WITH ACUTE CORONARY SYNDROME. THE ER STAFF BEGAN RESUSCITATION ON THE PATIENT USING AN IOT (INDUCTIVE OUTPUT TUBE), MCE (MEDICAL CARE EVALUATOR) AND THE AUTOPULSE PLATFORM. IT WAS REPORTED THAT THE RESCUE TEAM WHO BROUGHT THE PATIENT INTO THE HOSPITAL, PERFORMED MANUAL CPR AND CPR WITH THE AUTOPULSE PLATFORM DURING THIS RESUSCITATION (LENGTH OF TIME IS UNKNOWN). THE PATIENT ACHIEVED ROSC (RETURN OF SPONTANEOUS CIRCULATION) ONCE. WHEN THE PATIENT WAS BEING TRANSPORTED TO THE CORONAROGRAPHY ROOM (TO PERFORM A CORONARY ANGIOGRAPHY), SHE HAD A SECOND CARDIAC ARREST. THE PATIENT WAS BEING TRANSFERRED FOR ECMO (EXTRACORPOREAL MEMBRANE OXYGENATION) FOR SET UP. THE PATIENT WAS BEING PREPPED IN THE RIGHT FEMORAL ARTERY FOR A CORONARY ANGIOGRAPHY, ANGIOPLASTY AND STENT ON IVA (INTRAOPERATIVE VASCULAR ANGI

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 5728051 ↗

FDA clearance and classification

Cleared through 510(k) K112998 on Mar 15, 2012 (decision: Substantially Equivalent). Submitted by Zoll Circulation as “Autopulse Resuscitation System Model 1000”. The FDA review took 160 days. FDA record ↗

The FDA regulates product code DRM (compressor, cardiac, external) under 21 CFR 870.5200 as a Class II device. 21 CFR 870.5200 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K112998. One submission often covers many models, so check the product and lot details in each record.

  • Z-0118-2023 · Sep 22, 2022 · Open, Classified
    AutoPulse Li-ion Battery used on the AutoPulse Resuscitation System Model 100. used as an adjunct to manual CPR

Common questions about the AutoPulse®Resuscitation System 100

Has the AutoPulse®Resuscitation System 100 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00849111000550), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the AutoPulse®Resuscitation System 100?

The FDA's MAUDE database lists 5 adverse event reports for this device, received between Jun 15, 2016 and Mar 12, 2022. In those reports, the most common specific device problems are “Use of Device Problem” (2), “Visual Prompts will not Clear” (2) and “Device Stops Intermittently” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the AutoPulse®Resuscitation System 100?

None of the reports are classified as deaths, 1 as an injury and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the AutoPulse®Resuscitation System 100 FDA approved?

It was cleared through 510(k) K112998 on Mar 15, 2012. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the AutoPulse®Resuscitation System 100, and is it still sold?

The FDA's device database lists Zoll Circulation, Inc. as the company responsible for it (brand AutoPulse®Resuscitation System, model 100). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Compressor, Cardiac, External devices