AutoPulse®Resuscitation System 100 (REF 8700-0730-11)Recalls & reported problems
Zoll Circulation, Inc. · The AutoPulse System consists of 4 primary components, a reusable Platform, a single use chest compression assembly (LifeBand), a rechargeable battery, and a battery charger. · Class 2
- Adverse event reports
- 14
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 00849111000598), received between Feb 13, 2017 and Feb 24, 2026 — classified as 14 malfunctions.
The most frequently reported specific device problem is “Visual Prompts will not Clear” (9 reports).
1 other recall cover devices cleared under the same FDA submission (K112998); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Visual Prompts will not Clear9
- Use of Device Problem4
- Device Operates Differently Than Expected1
- Device Operational Issue1
- Failure to Power Up1
Patient problems
- No Clinical Signs, Symptoms or Conditions9
- Insufficient Information2
- No Patient Involvement2
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 24, 2026Use of Device Problem
THE CUSTOMER REPORTED THAT THE AUTOPULSE PLATFORM (SN (B)(6)) DOES NOT RECOGNIZE THE LIFEBAND. NO ADDITIONAL INFORMATION WAS PROVIDED. THIS WAS NOTICED DURING A MAINTENANCE CHECK. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24436054 ↗MalfunctionJan 8, 2025Visual Prompts will not Clear; Visual Prompts will not Clear
THE CUSTOMER REPORTED DURING PATIENT USE THE AUTOPULSE PLATFORM (SN (B)(6) DISPLAYED A USER ADVISORY (UA) 07 (DISCREPANCY BETWEEN LOAD 1 AND LOAD 2 TOO LARGE) MESSAGE. THE OPERATOR TRIED TO RE-ALIGN THE LIFEBAND BUT THE ERROR DID NOT CLEAR. NO FURTHER INFORMATION WAS PROVIDED. PATIENT'S STATUS INFORMATION WAS REQUESTED BUT THE CUSTOMER DID NOT PROVIDE A RESPONSE.
Patient problems: Insufficient Information
MAUDE report 21105757 ↗MalfunctionJul 3, 2024Visual Prompts will not Clear; Visual Prompts will not Clear
DURING SHIFT CHECK, THE AUTOPULSE PLATFORM (SN (B)(6)) DISPLAYED USER ADVISORY (UA) 07 (DISCREPANCY BETWEEN LOAD 1 AND LOAD 2 TOO LARGE) UPON POWERING UP. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19668632 ↗MalfunctionFeb 9, 2024Use of Device Problem; Use of Device Problem
DURING SHIFT CHECK, THE CUSTOMER NOTICED THAT THE AUTOPULSE PLATFORM (SN 31271) EMITTED A BURNING SMELL UPON POWERING UP. THE PLATFORM FUNCTIONS AS INTENDED, ASIDE FROM THE BURNING SMELL. THE CUSTOMER COULD NOT LOCATE WHERE THE BURNING SMELL WAS COMING FROM. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18681487 ↗MalfunctionAug 25, 2023Visual Prompts will not Clear; Visual Prompts will not Clear
DURING PATIENT USE, CUSTOMER REPORTED THAT THE AUTOPULSE PLATFORM (SERIAL #31331) DISPLAYED USER ADVISORY "(UA) 45" (DRIVESHAFT NOT AT "HOME" POSITION AFTER POWER-ON/RESTART) ERROR MESSAGE. PATIENT'S STATUS INFORMATION WAS REQUESTED BUT THE CUSTOMER DID NOT PROVIDE A RESPONSE.
Patient problems: Insufficient Information
MAUDE report 17621159 ↗MalfunctionDec 27, 2022Visual Prompts will not Clear; Visual Prompts will not Clear
DURING SHIFT CHECK, THE CUSTOMER REPORTED THE AUTOPULSE PLATFORM (SN (B)(4) DISPLAYED USER ADVISORY (UA) 17 (MAX MOTOR ON-TIME EXCEEDED DURING ACTIVE OPERATION) ERROR MESSAGE. THE CUSTOMER TRIED TO REPLACE THE AUTOPULSE LI-ION BATTERY BUT THE ERROR MESSAGE PERSISTED. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16057050 ↗MalfunctionOct 28, 2022Visual Prompts will not Clear; Visual Prompts will not Clear
DURING SHIFT CHECK, THE AUTOPULSE PLATFORM SN (B)(4) DISPLAYED USER ADVISORY (UA) 07 (DISCREPANCY BETWEEN LOAD 1 AND LOAD 2 TOO LARGE) UPON POWERING ON WHEN THERE IS NO WEIGHT ON THE PLATFORM. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15692627 ↗MalfunctionOct 5, 2022Failure to Power Up; Failure to Power Up
THE CUSTOMER REPORTED THAT DURING THE SHIFT CHECK, THE AUTOPULSE PLATFORM (B)(4) DID NOT POWER UP USING THE FULLY CHARGED AUTOPULSE LI-ION BATTERIES (B)(4) AND (B)(4). THE CUSTOMER STATED THAT THE BATTERY WAS FULLY CHARGED BEFORE USING IT WITH THE AUTOPULSE PLATFORM, AND THE CUSTOMER COULD NOT PROVIDE INFORMATION ON THE STATUS LEDS. THE CUSTOMER STATED THAT THEY DID NOT HAVE ANOTHER LI-ION BATTERY TO TEST THE AUTOPULSE PLATFORM. IN ADDITION, THE CUSTOMER REPORTED A BROKEN HEAD RESTRAINT ON THE AUTOPULSE PLATFORM. NO PATIENT INVOLVEMENT. PLEASE SEE THE FOLLOWING RELATED MFR REPORT: MFR 3010617000-2022-01755 FOR THE AUTOPULSE LI-ION BATTERY (B)(4). MFR 3010617000-2022-01856 FOR THE AUTOPULSE LI-ION BATTERY (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15545729 ↗MalfunctionOct 2, 2022Visual Prompts will not Clear; Visual Prompts will not Clear
DURING THE SHIFT CHECK, THE AUTOPULSE PLATFORM (SN (B)(4) DISPLAYED USER ADVISORY (UA) 20 (POSITION OUT OF RANGE) ERROR MESSAGE. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15526334 ↗MalfunctionFeb 16, 2021Use of Device Problem; Use of Device Problem
DURING DEVICE EVALUATION OF THE AUTOPULSE PLATFORM (SN: (B)(4)), THE PLATFORM FAILED THE LOAD CELL CHARACTERIZATION CHECK DURING FUNCTIONAL TESTING. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11335614 ↗MalfunctionDec 5, 2020Use of Device Problem; Use of Device Problem
ON (B)(6) 2020, DURING DEVICE EVALUATION, THE AUTOPULSE PLATFORM (SN (B)(4)) FAILED THE LOAD CELL CHARACTERIZATION CHECK DURING FUNCTIONAL TESTING. NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10955601 ↗MalfunctionJul 10, 2020Visual Prompts will not Clear; Visual Prompts will not Clear
DURING THE SHIFT CHECK, THE AUTOPULSE PLATFORM (SN (B)(4)) DISPLAYED USER ADVISORY (UA) 17 (MOTOR ON FOR TOO LONG DURING ACTIVE OPERATION) AND USER ADVISORY (UA) 18 (MAX TAKE-UP REVOLUTION EXCEEDED) ERROR MESSAGES ON THE USER CONTROL PANEL. NO PATIENT INVOLVEMENT.
Patient problems: No Patient Involvement
MAUDE report 10261664 ↗MalfunctionApr 1, 2020Visual Prompts will not Clear; Visual Prompts will not Clear
DURING SHIFT CHECK, CUSTOMER REPORTED THAT THE AUTOPULSE PLATFORM (SERIAL #(B)(4)) DISPLAYED A USER ADVISORY - "(UA) 41" (PATIENT TEMPERATURE SENSOR FAILURE) ERROR MESSAGE AND CRACKED BLACK COVER. NO PATIENT INVOLVEMENT.
Patient problems: No Patient Involvement
MAUDE report 9914435 ↗MalfunctionFeb 13, 2017Visual Prompts will not Clear; Device Operates Differently Than Expected; Device Operational Issue; Visual Prompts will not Clear; Device Operates Differently Than Expected; Device Operational Issue
IT WAS REPORTED THAT A SYSTEM ERROR / OUT OF SERVICE / PERFORM MANUAL CPR ERROR MESSAGE WAS OBSERVED ON THE AUTOPULSE PLATFORM (SN (B)(4)) DISPLAY SCREEN. IT WAS ALSO REPORTED THAT THE PLATFORM'S METAL HOOKS ON THE UPPER HOUSING WAS BROKEN. THE ISSUE OCCURRED DURING SHIFT CHECK. NO PATIENT WAS INVOLVED WITH THIS EVENT. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6327833 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K112998. One submission often covers many models, so check the product and lot details in each record.
- Z-0118-2023 · Sep 22, 2022 · Open, ClassifiedAutoPulse Li-ion Battery used on the AutoPulse Resuscitation System Model 100. used as an adjunct to manual CPR
Other Compressor, Cardiac, External devices
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External3,208 reports
- AutoPulse Li-ion Battery™ 100Zoll Circulation, Inc. · Compressor, Cardiac, External1,151 reports
- AutoPulse® Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External1,136 reports
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External317 reports
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External276 reports
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External250 reports
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External241 reports
- LifeBand® Load-distributing Band 100Zoll Circulation, Inc. · Compressor, Cardiac, External1 death199 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.