AutoPulse Li-ion Battery™ 100 (REF 8700-0752-02)Recalls & reported problems
Zoll Circulation, Inc. · Box containing a Lithium Ion (Li-Ion) battery for use with the AutoPulse ® Platform. · Class 2
All models of AutoPulse Li-ion Battery (9)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00849111001854), received between Nov 29, 2017 and Jun 18, 2020 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Battery Problem” (1 report).
1 other recall cover devices cleared under the same FDA submission (K112998); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Battery Problem1
- Device Operates Differently Than Expected1
- Low Battery1
Patient problems
- No Consequences Or Impact To Patient1
- No Patient Involvement1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 18, 2020Battery Problem; Battery Problem
DURING PATIENT USE, THE AUTOPULSE PLATFORM (SN: (B)(4)) STOPPED FUNCTIONING AND TURNED OFF AFTER PERFORMING A FEW COMPRESSIONS. IN ADDITION, THE CUSTOMER REPORTED THAT AUTOPULSE LI-ION BATTERY (SN: (B)(4)) WAS STUCK IN THE BATTERY COMPARTMENT OF THE AUTOPULSE PLATFORM. AS PER THE CUSTOMER, THERE WERE NO BREAKAGES OBSERVED ON EITHER THE BATTERY FINGER LATCH OR ON THE AUTOPULSE BATTERY COMPARTMENT. NO CONSEQUENCES OR IMPACT TO THE PATIENT. PLEASE SEE THE FOLLOWING RELATED MFR REPORT: MFR # 3010617000-2020-00622 FOR THE AUTOPULSE PLATFORM (SN: (B)(4)).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10172192 ↗MalfunctionNov 29, 2017Low Battery; Device Operates Differently Than Expected; Low Battery; Device Operates Differently Than Expected
AS REPORTED, DURING SHIFT CHECK, THE LI-ION BATTERY (B)(4) WAS INDICATING FOUR GREEN LEDS WHEN THE STATUS BUTTON WAS PRESSED. WHEN THE BATTERY WAS INSERTED INTO THE AUTOPULSE PLATFORM, IT WAS DISPLAYING AN ERROR MESSAGE "REPLACE / RECHARGE BATTERY". AFTER THE BATTERY WAS INSERTED INTO THE MULTI-CHEMISTRY CHARGER (MCC), IT WAS INDICATING FAIL (RED) LED. BATTERY STATUS HOWEVER, STILL INDICATING FOUR GREEN LEDS. NO PATIENT INVOLVEMENT WAS REPORTED.
Patient problems: No Patient Involvement
MAUDE report 7069663 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K112998. One submission often covers many models, so check the product and lot details in each record.
- Z-0118-2023 · Sep 22, 2022 · Open, ClassifiedAutoPulse Li-ion Battery used on the AutoPulse Resuscitation System Model 100. used as an adjunct to manual CPR
Other Compressor, Cardiac, External devices
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External3,208 reports
- AutoPulse Li-ion Battery™ 100Zoll Circulation, Inc. · Compressor, Cardiac, External1,151 reports
- AutoPulse® Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External1,136 reports
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External317 reports
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External276 reports
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External250 reports
- AutoPulse®Resuscitation System 100Zoll Circulation, Inc. · Compressor, Cardiac, External241 reports
- LUCAS 99576Jolife AB · Compressor, cardiac, external2 recalls9 deaths99 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page