Thermogard XP, Lang set A, Rohs, Refurb NARecalls & reported problems
Zoll Circulation, Inc. · The THERMOGARD is an integrated electro-mechanical heater/cooler that consists of a temperature monitor, a temperature controller unit, a heat exchanger unit, and roller pump. It supplies temperature controlled sterile saline to the indwelling Catheter that is placed percutaneously in the patient. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00849111075565), received between May 28, 2021 and May 28, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Insufficient Heating” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Insufficient Heating1
- Temperature Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 28, 2021Insufficient Heating; Temperature Problem; Insufficient Heating; Temperature Problem
A THERMOGARD XP CONSOLE (S/N (B)(4)) AND A QUATTRO CATHETER (LOT # 155467) WERE USED TO PROVIDE IVTM TREATMENT TO A PATIENT WHO NEEDED POST CARDIAC ARREST CARE. THE CATHETER WAS INSERTED INTO THE PATIENT'S LEFT FEMORAL VEIN WITH NO UNUSUAL RESISTANCE NOTED, AND A RADIAL ARTERIAL LINE WAS ALSO PLACED FOR MEDICAL PURPOSES. THE DWELL TIME OF THE CATHETER HAD BEEN APPROXIMATELY 26 HOURS WHEN THE HYPOTHERMIA PHASE ENDED, AND THE REWARMING PHASE STARTED. BEFORE THE INITIATION OF REWARMING, THE PATIENT'S BODY TEMPERATURE WAS MEASURED AT 36 °C. THE TARGET TEMPERATURE WAS SET TO 37°C, AND THE CONSOLE WAS SET TO A CONTROLLED REWARMING RATE OF 0.2°C/HOUR. ABOUT 15 HOURS INTO THE REWARMING PHASE OF THE TREATMENT, IT WAS NOTICED THAT THE PATIENT WAS NOT APPROPRIATELY WARMING, WHICH PROMPTED TROUBLESHOOTING OF THE THERMOGARD SYSTEM. THE PATIENT'S BODY TEMPERATURE WAS AT 36.7 °C WHEN THE ISSUE WAS NOTED. UPON FURTHER VISUAL INSPECTION, THE CUSTOMER NOTED THAT THE TUBING OF THE START-UP-KIT (SUK) (LOT # UNKNOWN) WAS BULGING IN THE AREA AROUND THE ROLLER PUMP, PREVENTING THE PUMP ROTOR FROM TURNING. THE NURSES REPLACED THE 500-ML SALINE BAG TO TROUBLESHOOT THE ISSUE; HOWEVER, THE SUK TUBING WAS STI
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11905507 ↗
Other System, Hypothermia, Intravenous, Cooling devices
- Thermogard XP® Thermogard XP, Lang set A, Non-RohsZoll Circulation, Inc. · System, Hypothermia, Intravenous, Cooling3 deaths2,522 reports
- ICY® Intravascular Heat Exchange Catheter Kit EU Applause Custom Luer (Heparin) IC-3893AEZoll Circulation, Inc. · System, Hypothermia, Intravenous, Cooling5 deaths198 reports
- QUATTRO® Intravascular Heat Exchange Catheter Kit Custom Luer Applause (Heparin) IC-4593Zoll Circulation, Inc. · System, Hypothermia, Intravenous, Cooling13 deaths165 reports
- SOLEX® Intravascular Heat Exchange Catheter Primum Kit Custom Luer Applause Hep SL-2593Zoll Circulation, Inc. · System, Hypothermia, Intravenous, Cooling2 deaths154 reports
- ICY® Intravascular Heat Exchange Catheter Kit Applause (Heparin) IC-3893Zoll Circulation, Inc. · System, Hypothermia, Intravenous, Cooling1 death154 reports
- SOLEX® Intravascular Heat Exchange Catheter Kit Custom Luer Applause Heparin EU SL-2593AEZoll Circulation, Inc. · System, Hypothermia, Intravenous, Cooling2 deaths117 reports
- QUATTRO® Intravascular Heat Exchange Catheter Kit Custom Luer Applause Heparin E IC-4593AEZoll Circulation, Inc. · System, Hypothermia, Intravenous, Cooling2 deaths98 reports
- QUATTRO® Intravascular Heat Exchange Catheter Kit Applause (Heparin) IC-4593Zoll Circulation, Inc. · System, Hypothermia, Intravenous, Cooling1 death87 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page