V.A.C.® SIMPLACE™ M8275045/5Recalls & reported problems

Kci USA, Inc. · VAC Simplace Ex Dressing Medium · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00849554001350), received between Oct 8, 2020 and Oct 22, 2024 — classified as 3 injuries.

The most frequently reported specific device problem is “Use of Device Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Use of Device Problem1

Patient problems

  • Fungal Infection2
  • Foreign Body In Patient1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 22, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ON 01-OCT-2024, THE FOLLOWING INFORMATION WAS PROVIDED BY THE PATIENT: V.A.C.® THERAPY WAS PLACED ON HOLD FOR TWO WEEKS DUE TO A FUNGAL INFECTION, ALLEGEDLY RELATED TO THE V.A.C.® DRAPE. ON 02-OCT-2024, THE FOLLOWING INFORMATION WAS PROVIDED BY THE PATIENT: ON (B)(6) 2024, V.A.C.® THERAPY WAS REMOVED DUE TO AN ALLEGED FUNGAL INFECTION. HER SKIN WAS SWEATING AND SHE IS NOT SURE IF THE IRRITATION WAS CAUSED BY THE V.A.C.® DRAPE, OR THE V.A.C.® TUBING RUBBING AGAINST HER SKIN. ON 07-OCT-2024, THE FOLLOWING INFORMATION WAS PROVIDED BY THE NURSE: V.A.C.® THERAPY WAS PLACED ON HOLD DUE TO A PERIWOUND FUNGAL INFECTION THAT WAS TREATED WITH NYSTATIN POWDER. THERE IS NO EVIDENCE OF V.A.C.® TUBING RUBBING AGAINST PATIENT¿S SKIN; PHOTOS DISPLAY A FUNGAL RASH TO THE AREA COVERED BY THE V.A.C.® DRAPE AND THERE IS DOCUMENTATION THAT A FUNGAL ODOR WAS PRESENT. V.A.C.® THERAPY HAS REMAINED ON HOLD AND FUNGAL INFECTION HAS RESOLVED. ON 22-OCT-2024, A DEVICE HISTORY RECORD REVIEW FOR V.A.C.® GRANUFOAM¿ DRESSING LOT NUMBER A09429V005 AND ASSOCIATED V.A.C.® DRAPE WAS COMPLETED. ALL END RELEASE TESTING OF PRODUCT AND PACKAGING MET SPECIFICATIONS. THE V.A.C.® GRANUFOAM¿ DRESSING WAS NOT RETURNED; THEREF

    Patient problems: Fungal Infection

    MAUDE report 20508578 ↗
  • InjuryDec 18, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ON 10-DEC-2020, A DEVICE HISTORY RECORD WAS COMPLETED FOR V.A.C.® SIMPLACE¿ EX DRESSING LOT NUMBER 60254438V005. ALL END RELEASE TESTING OF PRODUCT AND PACKAGING MET SPECIFICATIONS. ON 08-JAN-2021, QUALITY ENGINEERING COMPLETED AN EVALUATION OF THE ACTIV.A.C.¿ ION PROGRESS¿ REMOTE THERAPY MONITORING SYSTEM. ON 29-SEP-2020, THE DEVICE WAS TESTED PER QUALITY CONTROL PROCEDURE BY KCI FIELD SERVICE, AND THE UNIT PASSED THE QUALITY CONTROL CHECKS AND MET SPECIFICATIONS BEFORE PLACEMENT WITH THE PATIENT. ON (B)(6) 2020, THE DEVICE WAS PLACED WITH THE PATIENT. ON 06-JAN-2021, THE DEVICE WAS TESTED PER QUALITY CONTROL PROCEDURE BY KCI QUALITY ENGINEERING AND PASSED THE QUALITY CONTROL CHECKS AND MET SPECIFICATIONS. INSPECTION AND TESTING OF THE DEVICE DID NOT REVEAL ANY EVIDENCE OF AN OPERATIONAL MALFUNCTION OF THE UNIT.

    Patient problems: Fungal Infection

    MAUDE report 11042306 ↗
  • InjuryOct 8, 2020Use of Device Problem; Use of Device Problem

    ON 11-SEP-2020, THE FOLLOWING INFORMATION WAS REPORTED TO KCI BY THE PATIENT: ON (B)(6) 2020, THE V.A.C.® SIMPLACE¿ EX DRESSING WAS PLACED IN THE WOUND. ON (B)(6) 2020, A FOREIGN MATERIAL ALLEGED TO BE V.A.C.® SIMPLACE¿ EX DRESSING WAS ADHERED TO THE PATIENT'S WOUND AND DID NOT COME OUT AFTER SOAKING THE WOUND. ON (B)(6) 2020, THE PHYSICIAN SURGICALLY REMOVED THE FOREIGN MATERIAL. ON (B)(6) 2020, A DEVICE HISTORY RECORD REVIEW FOR V.A.C.® SIMPLACE¿ EX DRESSING LOT NUMBER 60238303V005 WAS COMPLETED. ALL END RELEASE TESTING OF THE PRODUCT AND PACKAGING MET SPECIFICATIONS.

    Patient problems: Foreign Body In Patient

    MAUDE report 10650830 ↗