GIBI HD B-2036Recalls & reported problems
Reshape Lifesciences Inc. · Gastrointestinal Boundary Identification and Sizing Tube 36 French · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00850007764227), received between Nov 3, 2022 and Nov 3, 2022 — classified as 1 malfunction.
The most frequently reported specific device problem is “Use of Device Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 3, 2022Use of Device Problem; Use of Device Problem
IT WAS REPORTED THAT THE SURGEON EXPERIENCED DIFFICULTIES WITH RETRIEVING THE GASTROINTESTINAL BOUNDARY IDENTIFIER (GIBI) HD GASTRIC TUBE DURING SURGERY. DURING THE PRIMARY LAPAROSCOPIC GASTRIC BYPASS, THE GIBI GASTRIC TUBE SIZE 36 FR WAS UTILIZED AS A GUIDE TO SIZE THE STOMACH POUCH AND ROUX LIMB. FOLLOWING THE CREATION OF THE STOMACH POUCH, THE TUBE WAS ADVANCED INTO THE JEJUNUM AND WAS USED AS A SIZING GUIDE TO CREATE THE GASTROJEJUNAL ANASTOMOSIS. THE TUBE'S SOFT TIP AND BALLOON WERE POSITIONED DISTALLY TO THE ANATOMOSIS SITE BEFORE SUTURE WAS MADE. UPON THE COMPLETION OF THE GASTROJEJUNAL ANASTOMOSIS, THE SURGEON ATTEMPTED TO RETRIEVE THE GASTRIC TUBE BY PULLING IT PROXIMALLY; HOWEVER, THE TUBE HAD DIFFICULTY PASSING THROUGH THE SUTURED GASTROJEJUNAL ANASTOMOSIS. THE SUTURE WAS LOOSENED TO ALLOW THE TUBE RETRIEVAL. THE SITE WAS RESUTURED. ENDOSCOPY WAS USED TO IDENTIFY AND REPAIR ANY LEAKAGE. DUE TO THE DIFFICULTY OF TUBE RETRIEVAL, THE SURGERY WAS EXTENDED. THERE WAS NO REPORT OF INJURY TO THE PATIENT OR DEVICE MALFUNCTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15720548 ↗
Other Tubes, Gastrointestinal (And Accessories) devices
- Bard® DigniShield® Stool Management System SMS002C. R. Bard, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)2 deaths525 reports
- CORTRAK* 2 ENTERAL ACCESS SYSTEM 20-0950Avanos Medical, Inc. · Tubes, gastrointestinal (and accessories)1 recall22 deaths134 reports
- Bard Tri-Funnel Replacement Gastrostomy Tube 000720Bard Access Systems, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 death170 reports
- EndoVive Safety PEG Kit M00566470Boston Scientific Corporation · TUBES, GASTROINTESTINAL (AND ACCESSORIES)1 recall1 death111 reports
- Kangaroo 8884711253Cardinal Health, Inc. · TUBES, GASTROINTESTINAL (AND ACCESSORIES)152 reports
- NutraGlide Nasal Feeding Tube ENFT-05055-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-06090-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
- NutraGlide Nasal Feeding Tube ENFT-06055-IApplied Medical Technology, Inc. · Tubes, Gastrointestinal (And Accessories)2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page