Skip to content

FlowTriever Catheter, M 10-102Recalls & reported problems

Inari Medical, Inc. · FlowTriever Catheter, 14 mm · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00850291007017), received between Feb 17, 2021 and Feb 17, 2021 — classified as 1 injury.

The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Improper or Incorrect Procedure or Method1

Patient problems

  • Anemia1
  • Hematoma1
  • High Blood Pressure/ Hypertension1
  • Hypovolemia1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 17, 2021Improper or Incorrect Procedure or Method

    A (B)(6) FEMALE PATIENT WITH CHRONIC PANCREATITIS PRESENTED TO THE EMERGENCY DEPARTMENT WITH HYPERTENSION AND SUSPECTED ACUTE MYOCARDIAL INFARCTION (MI). SHE WAS DIAGNOSED WITH A PULMONARY EMBOLISM (PE) AFTER UNDERGOING A RIGHT HEART CATHETERIZATION AND PULMONARY ANGIOGRAM (ACUTE MI WAS RULED OUT). ON (B)(6) 2021, THE INARI TRIEVER16 (T16), TRIEVER20 (T20), AND MEDIUM FLOWTRIEVER (FT) DISKS WERE USED TO ATTEMPT TO TREAT THE PE. THE PATIENT REMAINED HYPERTENSIVE AND TACHYCARDIC THROUGHOUT THE MECHANICAL THROMBECTOMY, WITH MARKEDLY ELEVATED RIGHT-SIDED PULMONARY AND ATRIAL PRESSURES. THE CLOT IN THE RIGHT PULMONARY ARTERY WAS SUCCESSFULLY ASPIRATED, BUT CLOT REMAINED IN THE LEFT LOWER LOBE (LLL) DESPITE USE OF THE T20, T16, AND MEDIUM FT DISKS. AN EKOS CATHETER WAS PLACED DUE TO THE PERSISTENT TACHYCARDIA, AND THE CASE WAS CONCLUDED. THE FOLLOWING DAY, RIGHT HEART CATHETERIZATION REVEALED RESOLUTION OF RIGHT VENTRICLE FAILURE AND NORMALIZATION OF RIGHT ATRIAL PRESSURE (~20 REDUCED TO ~6 MMHG). THE PATIENT'S TACHYCARDIA AND NAUSEA PERSISTED, AND THE HGB LEVEL DECREASED FROM 9 TO 7 GM/DL DUE TO 600 CC OF BLOOD BEING ASPIRATED DURING THE PROCEDURE. THE PATIENT WAS INFUSED WITH 2 UNITS O

    Patient problems: Anemia; Hematoma; High Blood Pressure/ Hypertension; Hypovolemia

    MAUDE report 11336350 ↗

FDA clearance and classification

The FDA regulates product code QEW (peripheral mechanical thrombectomy with aspiration) under 21 CFR 870.5150 as a Class II device. 21 CFR 870.5150 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the FlowTriever Catheter, M 10-102

Has the FlowTriever Catheter, M 10-102 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00850291007017), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the FlowTriever Catheter, M 10-102?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Feb 17, 2021. That report lists device problem “Improper or Incorrect Procedure or Method” (1); patient problems “Anemia” (1), “Hematoma” (1) and “High Blood Pressure/ Hypertension” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the FlowTriever Catheter, M 10-102?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the FlowTriever Catheter, M 10-102, and is it still sold?

The FDA's device database lists Inari Medical, Inc. as the company responsible for it (brand FlowTriever Catheter, M, model 10-102). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Peripheral Mechanical Thrombectomy With Aspiration devices

All Peripheral Mechanical Thrombectomy With Aspiration devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page