NeVa pVasc 6.0 x 44 mm - Flow Restoration, 3 Drop Zones - 180 cm wire System VP-6044-F3RRRecalls & reported problems

Vesalio · The pVasc Device is a series of specialized devices with an expandable distal tip which is temporarily inserted into the vasculature to restore blood flow in vessels blocked by an embolus. The expandable tip is a tubular mesh structure laser cut from Nitinol with radiopaque markers in the middle of the device and distal tip. In its expanded shape, the device creates a highly flexible, hybrid closed cell structure. The pusher assembly is composed of an introducer and delivery pusher and is used to deliver the device to the treatment site. The introducer consists of a polymer tube, which protects the device and distal segment of the delivery pusher from damage and creates an uninterrupted passage for the device to be transferred through the microcatheter. The delivery pusher varies in flexibility from the proximal to distal end with the distal section of the delivery is the most flexible and has a radiopaque marker. The pusher controls the deployment of the pVasc Device and facilitates advancement and removal of the device through a microcatheter. It is used to track the device to the intended delivery site. · Class 2

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00851279008514), received between May 5, 2025 and May 19, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1
  • Material Integrity Problem1
  • Solder Joint Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 19, 2026Material Integrity Problem

    DURING THROMBECTOMY OF LOWER LEG (TIBIAL ARTERY) THE PVASC DETACHED FROM THE DELIVERY WIRE WHILE TRYING TO REMOVE DEVICE FROM BODY. LARGE PIECE OF TISSUE (NOT CLOT) WAS TRAPPED BETWEEN THE TIP OF THE PENUMBRA BOLT 7 AND THE PVASC DEVICE. THIS LARGE CHUNK GOT CAUGHT IN THE PVASC AND SINCE IT WAS SOLID AND MUCH LARGER THAN THE BOLT 7 TIP, THE FRICTION AN FORCE CAUSED THE PVASC TO DETACH.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25223015 ↗
  • MalfunctionJul 29, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    A PVASC 6.0X44 EXPANDABLE TIP DETACHED DURING A PROCEDURE WHILE ATTEMPTING TO WITHDRAW THE DEVICE THROUGH A STENTED REGION OF THE BLOOD VESSEL. IT WAS OBSERVED THAT THE EXPANDABLE TIP GOT STUCK ON THE STRUT OF THE STENT. THE PHYSICIAN UNSUCCESSFULLY ATTEMPTED TO WITHDRAW THE DETACHED TIP. HE DECIDED TO COMPRESS THE EXPANDABLE TIP AGAINST THE WALL OF THE ARTERY USING A NEW STENT. FOLLOWING THE DEVICE DETACHMENT AND PLACEMENT OF NEW STENT, THE PATIENT REMAINED CLINICALLY STABLE AND WAS DISCHARGED WITHOUT ANY NEGATIVE AFTER-EFFECTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22649127 ↗
  • MalfunctionMay 5, 2025Solder Joint Fracture; Solder Joint Fracture

    DURING A PROACTIVE OUTREACH TO THE PHYSICIAN, (B)(6) WAS NOTIFIED THAT DURING SURGERY ON WEDNESDAY ((B)(6) 2025), THE PVASC 6.0X44 EXPANDABLE TIP DETACHED FROM THE PUSHER WIRE AND THE EXPANDABLE TIP COULD NOT BE REMOVED. THE PUSHER WIRE WAS REMOVED AND DISCARDED. UPON FOLLOW-UP, THE FOLLOWING INFORMATION WAS PROVIDED BY THE PHYSICIAN: - THE PROCEDURE INVOLVED A CHRONIC ILIAC OCCLUSION. - A 2.7 HEADHUNTER WAS USED THOUGH A BOLT 6 TO DEPLOY THE PVASC DEVICE. - ONCE ENGAGED WITH THE CHRONIC CLOT, AN ATTEMPT WAS MADE TO WITHDRAW THE PVASC DEVICE INTO THE PENUMBRA BOLT 6 CATHETER BY A NON-PHYSICIAN WHILE THE PHYSICIAN WAS NOT SUPERVISING THEM. - THE PRODUCT DETACHED AND THE PHYSICIAN TACKED IT WITH A STENT. THE PHYSICIAN MENTIONED THAT HE PLANNED TO PLACE A STENT IN THE VESSEL ANYWAY. - THE PVASC WIRE WAS DISPOSED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21963422 ↗

Other Peripheral Mechanical Thrombectomy With Aspiration devices

All Peripheral Mechanical Thrombectomy With Aspiration devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.