NeuroPace® Cortical Strip Lead Kit CL-335-10-K (UDI 00855547005304)Recalls & reported problems

Neuropace, Inc. · The NeuroPace® Cortical Strip Lead package contains 1 Cortical Strip Lead, 2 Lead Caps, 4 Suture Sleeves and 1 Tunneling Tool Straw. · Class 3 · Implant

All models of NeuroPace Cortical Strip Lead Kit (4)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00855547005304), received between Apr 19, 2023 and Jan 13, 2026 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Impedance Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Impedance Problem1
  • Signal Artifact/Noise1

Patient problems

  • Bacterial Infection1
  • Fluid Discharge1
  • Impaired Healing1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 13, 2026Adverse Event Without Identified Device or Use Problem

    ON (B)(6) 2025, THE PATIENT HAD LEFT TEMPORAL LOBE RESECTION AND LEAD IMPLANT. ON (B)(6) 2025, THE PATIENT REPORTED POOR WOUND HEALING, FLUID DISCHARGE, AND INFECTION. ON (B)(6) 2025, THE PATIENT HAD A WOUND WASHOUT AND LEAD EXPLANT. AFTER SURGERY THE PATIENT WAS ADMINISTERED A TRIPLE ANTIBIOTIC REGIMEN (ORAL AND IV)THE TREATING CENTER GAVE THE DIAGNOSIS OF A DEEP INCISIONAL INFECTION.

    Patient problems: Bacterial Infection; Fluid Discharge; Impaired Healing

    MAUDE report 24063341 ↗
  • MalfunctionApr 19, 2023Signal Artifact/Noise; Impedance Problem; Signal Artifact/Noise; Impedance Problem

    DURING AN ECOG REVIEW PERFORMED ON 08/09/2022, AN UNUSUAL SIGNAL WAS OBSERVED, INDICATIVE OF A LEAD BREAK ON THE RIGHT SUB-TEMPORAL STRIP. THE BREAK APPEARS TO HAVE OCCURRED AROUND FEB 2022. THERE WAS NO CHANGE IN TREATMENT, THE DOCTOR REPORTED THAT THE FRACTURE DID NOT SEEM TO AFFECT EFFICACY OF THE RNS SYSTEM. TROUBLESHOOTING INCLUDED PALPITATION OF THE LEAD WHICH RESULTED IN HIGH IMPEDANCE AND SIGNAL ARTIFACT. NO KNOWN TRAUMA WAS REPORTED, AND A CAUSE WAS UNABLE TO BE DETERMINED. THE LEAD WAS SECURED WITH A BURR HOLD COVER. THE LEAD HAS BEEN IMPLANTED 1.7 YEARS AT TIME OF LEAD BREAK OBSERVATION. ON (B)(6) 2023 THE PATIENT UNDERWENT A LEAD REVISION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16769935 ↗

Other Implanted brain stimulator for epilepsy devices

All Implanted brain stimulator for epilepsy devices →