Hot Dog Multi-Position Warming Blanket B105Recalls & reported problems
Augustine Temperature Management LLC · Labeled Hot Dog Multi-Position Warming Blanket B105 · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00855913001381), received between Jan 22, 2025 and Jan 22, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Degraded” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Degraded1
- Use of Device Problem1
Patient problems
- Full thickness (Third Degree) Burn1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 22, 2025Degraded; Use of Device Problem; Degraded; Use of Device Problem
AS DESCRIBED BY THE REPORTER INITIALLY IN AN EMAIL "WHEN REMOVING (KC-T1) B105 [HOTDOG BLANKET B105] FROM THE PATIENT AFTER THE SURGERY, REDNESS INCLUDING PARTIAL BLISTERS WERE OBSERVED FROM THE HIGH PART OF THE PATIENT'S CHEST TO THE UPPER SIDE OF HER TORSO". LATER ON, ON (B)(6) 2024, WE GOT ADDITIONAL DETAILS IN A FILLED-OUT INCIDENT REPORT: "PROCEDURE: ARTIFICIAL JOINT REPLACEMENT WAS PERFORMED FOR THE PATIENT'S LEFT OSTEOARTHRITIS OF THE KNEE. BEFORE THE OPERATION, A DOUBLE LAYER OF A BATH TOWEL WERE PLACED ON BOTH UPPER LIMBS AND ANTERIOR CHEST, AND A PAD OF THE DRESSING (THE HOTDOG [WARMING BLANKET B105]) WAS PLACED ON IT AND SET AT 38C (10 A.M.) WHEN REMOVING THE HOTDOG AFTER THE SURGERY (12 NOON), IT WAS CONFIRMED THAT THE TEMPERATURE WAS MODERATE. AFTER EXTUBATION, PATIENT'S SKIN WAS OBSERVED AND TWO BLISTER FORMATIONS WERE CONFIRMED IN THE RIGHT ARMPIT AND ON ANTERIOR CHEST AS WELL AS REDNESS OF 15X10CM SIZE IN THE RIGHT ANTERIOR CHEST AREA." ON (B)(6) 2024, THE REPORTER SENT A CORRECTION TO THE INCIDENT REPORT, THEY MARKED THE INJURY IS OF A 3RD DEGREE, WITH A SIZE OF LESS THAN 1 SQ INCH (6.5 SQ CM). PER AUGUSTINE'S INVESTIGATION: THE HOTDOG PATIENT WARMING BLANKET B105
Patient problems: Full thickness (Third Degree) Burn
MAUDE report 21213454 ↗
Other System, Thermal Regulating devices
- Arctic Sun® 5000 50000000Medivance, Inc. · System, thermal regulating1 recall3 deaths6,903 reports
- Arctic Sun® 5000 50000000EMedivance, Inc. · System, thermal regulating1 recall2 deaths4,413 reports
- Arctic Sun Stat 60000000Medivance, Inc. · System, thermal regulating1 recall1,613 reports
- Arctic Sun® 5000 50000000LMedivance, Inc. · System, thermal regulating1 recall388 reports
- Arctic Sun® Temperature Management System, ArcticGel™ Pads 31802Medivance, Inc. · System, thermal regulating1 recall385 reports
- Altrix 8001Stryker Corporation · System, thermal regulating1 recall160 reports
- Arctic Sun Stat 60000000LMedivance, Inc. · System, thermal regulating1 recall104 reports
- HotDog Temperature Management System WC77Augustine Temperature Management LLC · System, Thermal Regulating2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page