Walrus FG 00100-01Recalls & reported problems
Q'Apel Medical LLC · 087 Balloon Guide Catheter System, 90cm · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00857545008011), received between Mar 8, 2024 and Mar 8, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Use of Device Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Use of Device Problem1
Patient problems
- Vascular Dissection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 8, 2024Use of Device Problem; Use of Device Problem
RETROACTIVE REPORTING TO THE FDA OF AN INCIDENT THAT OCCURED IN THE UK MARKET ON 4/20/2023. Q'APEL MEDICAL BECAME AWARE OF THE INCIDENT ON 4/20/2023. Q'APEL MEDICAL FILED AN INITIAL MIR REPORT ON 4/26/23. Q'APEL MEDICAL FILED A FINAL MIR REPORT ON 5/24/23. CONCLUSION: THE DEVICE DID NOT MALFUNCTION. THE OPERATOR CONFIRMED HE OVER-INFLATED ACCORDING TO THE VESSEL SIZE AND DID NOT FOLLOW RECOMMENDATIONS OR THE MANUFACTURER'S INSTRUCTIONS. WALRUS USED WAS THE 90CM VERSION BG8087-090 LOT NO. FG220811J-03. PHYSICIAN NAME: DR (B)(6). HOSPITAL NAME: (B)(6) HOSPITAL. 75 YO MALE WITH A RIGHT M1 OCCLUSION SUFFERING AN ACUTE ISCHEMIC STROKE. PATIENT WAS TREATED UNDER GENERAL ANESTHESIA. OTHER DEVICES UTILIZED IN THE PROCEDURE WERE A SOFIA PLUS ASPIRATION CATHETER, PHENNOM 21 MICRO CATHETER AND A SOLITAIRE STENT. RETRIEVER THE WALRUS BGC WAS PLACED IN THE DISTAL CERVICAL SEGMENT OF THE R ICA PHYSICIAN INITIALLY INFLATED THE WALRUS WITH APPROX 0.3CC'S OF CONTRAST/SALINE MIX. THEY FELT THAT THE BALLOON WAS NOT STABLE SO CONTINUED TO INFLATE WITH MAXIMUM RECOMMENDED VOLUME OF 0.6CC'S. PHYSICIAN COMPLETED ONE PASS WITH THE SOLITAIRE STENT RETRIEVER AND THE SOFIA PLUS ASPIRATION CATHETER. ONCE THAT
Patient problems: Vascular Dissection
MAUDE report 18871670 ↗
Other Catheter, Percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.