Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00858015005349), received between May 22, 2026 and May 22, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation, Positioning or Separation Problem1
  • Improper or Incorrect Procedure or Method1

Patient problems

  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 22, 2026Improper or Incorrect Procedure or Method; Activation, Positioning or Separation Problem

    DURING A STEREOTACTIC BIOPSY USING MAMMOTOME REVOLVE WITH A SIEMENS UPRIGHT, THE RADIOLOGIST ENCOUNTERED TIP SHEAR WITH (1) STAR0833. THE RADIOLOGIST FIRST USED MMK0801. THE MARKER WAS DEPLOYED, BUT THEY WERE UNABLE TO SEE IT IN THE BREAST. IT COULD HAVE BEEN SUPERIMPOSED BEHIND THE PROBE. THE PHYSICIAN THEN DECIDED TO ADD A SECOND CLIP AND CHOSE TO USE STAR0833. HOWEVER, DURING DEPLOYMENT, THE MARKER BECAME STUCK IN THE CHAMBER, AND WHEN THEY TRIED TO PULL THE DEPLOYMENT DEVICE OUT, IT WAS STUCK IN THE BREAST. AT THE VERY END OF THE MARKER DEPLOYMENT DEVICE, THE WHITE TIP WAS PULLED OFF JUST ENOUGH THAT THE "FORK"- LOOKING END CAUGHT THE BREAST TISSUE, AND THEY WERE UNABLE TO PULL THE DEVICE BACK OUT. THE PHYSICIAN HAD TO MAKE AN ADDITIONAL INCISION ON THE BREAST TO WIDEN THE AREA TO BE ABLE TO PULL THE DEVICE OUT.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 25259369 ↗