Thoraguard FGN-1387Recalls & reported problems
Centese, Inc. · Thoraguard Control Module · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00860000436427), received between Aug 9, 2025 and Aug 9, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Suction Failure” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Suction Failure1
Patient problems
- Pneumothorax1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 9, 2025Suction Failure; Suction Failure
ACCORDING TO THE USER FACILITY'S REPORT (MDR MW5171897), ON (B)(6) 2025, A PATIENT UNDERWENT THORACIC SURGERY AND POSTOPERATIVELY HAD A CHEST TUBE CONNECTED TO A THORAGUARD DIGITAL CHEST DRAINAGE SYSTEM. ON POST-OPERATIVE DAY 1, A SCHEDULED MORNING CHEST X-RAY SHOWED A LARGE LEFT-SIDED PNEUMOTHORAX. THE PATIENT WAS ASYMPTOMATIC AND WELL-APPEARING AT THE TIME OF DISCOVERY. THE ATTENDING SURGEON DISCONNECTED THE CHEST TUBE FROM THE THORAGUARD SYSTEM AND CONNECTED IT TO AN ANALOG CHEST DRAIN, WHICH RELEASED AIR FROM THE LEFT SIDE. THROUGHOUT THE EXCHANGE, THE THORAGUARD DEVICE DID NOT DETECT AN AIR LEAK, AND AFTER REMOVAL FROM THE PATIENT'S CHEST TUBE, THE SYSTEM STILL DID NOT REGISTER AN AIR LEAK. THE PATIENT REMAINED ASYMPTOMATIC FOLLOWING THE INTERVENTION.
Patient problems: Pneumothorax
MAUDE report 22766654 ↗
Other Pump, Portable, Aspiration (Manual Or Powered) devices
- AXS Universal Aspiration Tubing 077.0193Medela AG · Pump, Portable, Aspiration (Manual Or Powered)1 recall1 report
- Medline HCS7001Medline Industries, Inc. · PUMP, PORTABLE, ASPIRATION (MANUAL OR POWERED)20 reports
- SSCOR VX-2® 2310BVSscor, Inc. · Pump, Portable, Aspiration (Manual Or Powered)10 reports
- CARE-E-VAC 3Ohio Medical, LLC · Pump, Portable, Aspiration (Manual Or Powered)8 reports
- Thopaz+Medela AG · Pump, Portable, Aspiration (Manual Or Powered)2 reports
- Precision Medical Inc. PM65HGPrecision Medical, Inc. · Pump, Portable, Aspiration (Manual Or Powered)1 report
- HAEMONETICS SMARTSUCTION TECHNOLOGY HAR-A-1000Haemonetics Corporation · Pump, Portable, Aspiration (Manual Or Powered)1 report
- Suction Irrigation Cartridge Set C7100Applied Medical Resources Corporation · Pump, Portable, Aspiration (Manual Or Powered)1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page