Versipass Suture Passer Needle 4727Recalls & reported problems

Lincotek Medical LLC · Suture passer needle for the Versipass Suture Passer · Class 1

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00860794002679), received between Apr 23, 2026 and Jun 8, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Material Fragmentation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Fragmentation1
  • Material Integrity Problem1

Patient problems

  • Laceration(s)1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 8, 2026Material Fragmentation

    THE COMPLAINT WAS REPORTED FROM STRYKER INVOLVING THE VERSIPASS NEEDLE MANUFACTURED BY LINCOTEK MEDICAL LLC. THE EVENT TOOK PLACE IN THE UNITED STATES. DURING A SURGICAL PROCEDURE ON (B)(6) 2026, TWO VERSIPASS NEEDLES FRACTURED DURING USE. THE FIRST NEEDLE FRACTURED APPROXIMATELY HALFWAY DOWN THE SHAFT DURING DEPLOYMENT. A SECOND NEEDLE WAS SUBSEQUENTLY OPENED AND USED; HOWEVER, THIS NEEDLE FRACTURED AT THE DISTAL TIP IN TWO LOCATIONS RESULTING IN BROKEN NEEDLE FRAGMENTS BECOMING DISLODGED INTO THE PATIENT'S MENISCUS. X-RAYS WERE UTILIZED TO IDENTIFY AND LOCATE THE RETAINED NEEDLE FRAGMENTS. APPROXIMATELY ONE HOUR OF ADDITIONAL SURGICAL TIME WAS REQUIRED TO LOCATE AND RETRIEVE THE BROKEN NEEDLE PIECES FROM THE PATIENT. DUE TO THE PRESENCE OF RETAINED FRAGMENTS AND THE EFFORTS REQUIRED FOR RETRIEVAL THE PLANNED MENISCUS REPAIR PROCEDURE COULD NOT BE COMPLETED AS INTENDED. INSTEAD, A PARTIAL LATERAL MENISCECTOMY WAS PERFORMED IN ORDER TO REMOVE THE NEEDLE FRAGMENTS ALONG WITH THE AFFECTED MENISCAL TISSUE. THE EVENT RESULTED IN PATIENT INVOLVEMENT, MEDICAL INTERVENTION, AND A SURGICAL DELAY. PHOTOGRAPHS OF THE BROKEN NEEDLES AND X-RAYS WERE PROVIDED WITH THE COMPLAINT.

    Patient problems: Laceration(s)

    MAUDE report 25427387 ↗
  • MalfunctionApr 23, 2026Material Integrity Problem

    LINCOTEK MEDICAL WAS NOTIFIED BY STRYKER ON 04/08/2026 OF A NEEDLE BREAKAGE EVENT THAT OCCURRED AT THE SURGICAL SITE. DURING A MENISCUS ROOT REPAIR PROCEDURE USING THE VERIPASS SUTURE PASSER AND NEEDLE, TWO NEEDLE TIPS FRACTURED WITHIN THE PATIENT. ONE FRAGMENT WAS SUCCESSFULLY RETRIEVED, WHILE THE OTHER REMAINED EMBEDDED IN THE MENISCAL TISSUE AT THE SITE OF BREAKAGE. THE ISSUE WAS IDENTIFIED DURING THE PROCEDURE, WHICH WAS COMPLETED SUCCESSFULLY WITHOUT ANY REPORTED DELAY. HOWEVER, THE ADVERSE OUTCOME WAS THAT ONE NEEDLE TIP REMAINED IN THE PATIENT'S MENISCUS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24972039 ↗

Other Needle, Suturing, Disposable devices

All Needle, Suturing, Disposable devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.