Skip to content

microTargeting™ Electrode 44975Z-00267Recalls & reported problems

Fhc, Inc. · microTargeting(TM) Electrode, sterile, D.Zap(Z), for use with Platform · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
1
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00873263002674), received between Feb 3, 2025 and Feb 3, 2025 — classified as 1 death.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Intracranial Hemorrhage1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • DeathFeb 3, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A CASE WAS COMPLETED ON (B)(6) 2025 AT (B)(6) MEDICAL CENTER, (B)(6) WITH DR. (B)(6), WHERE A 57 Y/O PATIENT HAD BOSTON SCIENTIFIC LEADS IMPLANTED BILATERALLY IN STN. MER WAS PERFORMED ON BOTH HEMISPHERES SIMULTANEOUSLY USING FHC 44975Z MICROELECTRODES (A SINGLE TRACK PER SIDE) AND A GUIDELINE 4000 LP+ SYSTEM. OTHER FHC PRODUCTS USED DURING THE CASE WERE STARFIX PLATFORM, 66-IT-03P INSERTION TUBES, 66-ST-12P STYLET. PATIENT RESPONDED WELL TO STIMULATION AND O-ARM IMAGING SHOWED ACCURATE TARGETING. POST-OP CT SHOWED NO ABNORMALITIES AND PATIENT WAS DISCHARGED THE SAME DAY OF SURGERY. THE PATIENT WAS DOING WELL AND HAD GONE BACK TO WORK. FACILITY DID NOT RETAIN LOT# OF PRODUCT USED AND DISPOSED OF PRODUCTS. ON 01/16/2025 FHC, INC. REPRESENTATIVE WAS ATTENDING ANOTHER CASE AT (B)(6) MEDICAL CENTER WITH DR. (B)(6) WHERE DURING THE CASE, THE DR. INFORMED THE FHC REP, THAT THE PATIENT THEY OPERATED ON (B)(6) 2025 WAS FOUND DEAD THIS WEEK AND THAT THEY WERE GOING TO CONDUCT AN AUTOPSY TO DETERMINE THE CAUSE OF DEATH. THE AUTOPSY WAS CONDUCTED ON (B)(6) 2025 WHERE AN INTRACEREBRAL HEMORRHAGE (ICH) AT DBS-LEAD ENTRY SITE AND THALAMUS WAS DETERMINED TO BE CAUSE OF DEATH. SINCE POST-OP CT WAS

    Patient problems: Intracranial Hemorrhage

    MAUDE report 21295201 ↗

Other ELECTRODE, DEPTH devices

All ELECTRODE, DEPTH devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page