Skip to content

BioGlue Surgical Adhesive BG3502-5-USRecalls & reported problems

Artivion, Inc. · 2mL Syringe and Standard Applicator Tips · Class 3 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00877234000232), received between Mar 28, 2019 and Mar 28, 2019 — classified as 1 injury.

4 other recalls cover devices cleared under the same FDA submission (P010003); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Unspecified Infection1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 28, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ACCORDING TO THE INITIAL REPORT, A POST OPERATIVE INFECTION OCCURRED. ACCORDING TO THE COMPLAINANT, PATIENT IS STILL BEING FOLLOWED AS OF (B)(6) 2019. (B)(6) 2018: CULTURED FOR STAPHYLOCOCCUS AUREUS. ON (B)(6) 2019: LIGHT GROWTH OF ENTEROCOCCUS FAECALIS AND LIGHT GROWTH OF STREPTOCOCCAL A. ADDITIONAL INFORMATION WAS RECEIVED. "THE INFECTION THAT OCCURRED AT OUR FACILITY WAS ON A PATIENT WHO HAD A LUMBAR LAMINECTOMY ON (B)(6) 2018. WE BROUGHT HER BACK TO THE OR [OPERATING ROOM] ON (B)(6) 2018 WHEN IT WAS DISCOVERED THAT SHE HAD A CSF [CEREBROSPINAL FLUID LEAK] LEAK FROM HER INITIAL SURGERY THAT REQUIRED REPAIR. THE [PRODUCT] WAS USED FOR THE SECOND SURGERY, WHEN THE SURGEON PLACED A BLOOD PATCH TO REPAIR THE CSF LEAK.".

    Patient problems: Unspecified Infection

    MAUDE report 8461873 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P010003. One submission often covers many models, so check the product and lot details in each record.

  • Z-0384-2022 · Oct 7, 2021 · Terminated
    BioGlue Surgical Adhesive, Model BG3510-5-G
  • Z-2556-2018 · Jun 4, 2018 · Terminated
    BioGlue Spreader Tip, 12mm, Sterile, RX Only. Product Usage: BioGlue is indicated for use as an adjunct to standard methods of achieving hemostasis (such as sutures and staples) i
  • Z-2623-2017 · May 19, 2017 · Terminated
    BioGlue Surgical Adhesive, Model/Catalog Number BG3510-5-J
  • Z-1674-2014 · Apr 25, 2014 · Terminated
    BG3515-5 US 5mL BioGlue Surgical Adhesive. BioGlue Surgical Adhesive (BioGlue) is indicated for use as an adjunct to standard methods of achieving hemostasis (such as sutures and

Other Glue,Surgical,Arteries devices

All Glue,Surgical,Arteries devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page