PhotoFix Decellularized Bovine Pericardium PFP8X14Recalls & reported problems
Artivion, Inc. · Decellularized Bovine Pericardium · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00877234000560), received between Aug 19, 2026 and Aug 19, 2026 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Unspecified Heart Problem1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 19, 2026Adverse Event Without Identified Device or Use Problem
According to the initial report received pertaining to reoperation for hole in middle of photofix patch of VSD that was implanted in April. \\Additional information indicates the patient is a 30-year-old male with Down Syndrome. A Konno procedure was performed in (b)(6) 2026, during which a PhotoFix patch was implanted to repair a ventricular septal defect (VSD). Follow-up echocardiography showed billowing movement of the patch. Reoperation was subsequently performed to remove the PhotoFix patch, and the surgeon observed a hole in the center of the patch.\\This investigation is relegated to PFP 8X14 Lot Number: 21082725 with allegation of poor product quality.
Patient problems: Unspecified Heart Problem
MAUDE report 50329883 ↗
FDA clearance and classification
The FDA regulates product code PSQ (intracardiac patch or pledget, biologically derived) under 21 CFR 870.3470 as a Class II device. 21 CFR 870.3470 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
FDA definition of this device type: To repair defects, to be used for patch grafting, to repair tissue, and to buttress sutures in the heart and vasculature.
Common questions about the PhotoFix Decellularized Bovine Pericardium PFP8X14
Has the PhotoFix Decellularized Bovine Pericardium PFP8X14 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00877234000560), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the PhotoFix Decellularized Bovine Pericardium PFP8X14?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Aug 19, 2026. That report lists patient problem “Unspecified Heart Problem” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the PhotoFix Decellularized Bovine Pericardium PFP8X14?
None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the PhotoFix Decellularized Bovine Pericardium PFP8X14 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the PhotoFix Decellularized Bovine Pericardium PFP8X14, and is it still sold?
The FDA's device database lists Artivion, Inc. as the company responsible for it (brand PhotoFix Decellularized Bovine Pericardium, model PFP8X14). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Intracardiac Patch Or Pledget, Biologically Derived devices
- Supple Peri-Guard SPG1016Synovis Life Technologies, Inc. · Intracardiac patch or pledget, biologically derived1 recall0 reports
- Supple Peri-Guard SPG0814Synovis Life Technologies, Inc. · Intracardiac patch or pledget, biologically derived1 recall0 reports
- Supple Peri-Guard SPG0406Synovis Life Technologies, Inc. · Intracardiac patch or pledget, biologically derived1 recall0 reports
- PhotoFix Decellularized Bovine Pericardium PFP6X8Artivion, Inc. · Intracardiac Patch Or Pledget, Biologically Derived4 reports
- PhotoFix Decellularized Bovine Pericardium PFP0.8X8Artivion, Inc. · Intracardiac Patch Or Pledget, Biologically Derived3 reports
- Vascu-Guard VG0108Synovis Life Technologies, Inc. · Intracardiac Patch Or Pledget, Biologically Derived1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page