Skip to content

Vanguard® Knee System 183050Recalls & reported problems

Biomet Orthopedics, LLC · Class 2 · Implant

All models of Vanguard Knee System (147)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00880304270626), received between May 6, 2022 and Jan 29, 2026 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Inaccurate Information” (1 report).

20 other recalls cover devices cleared under the same FDA submission (K023546, K033489, K113550, K171054); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Inaccurate Information1
  • Loosening of Implant Not Related to Bone-Ingrowth1

Patient problems

  • Failure of Implant1
  • Insufficient Information1
  • Loss of Range of Motion1
  • No Clinical Signs, Symptoms or Conditions1
  • Pain1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 29, 2026Inaccurate Information

    IT WAS REPORTED THAT A CEMENTLESS FEMORAL COMPONENT WAS IMPLANTED DURING A TOTAL KNEE ARTHROPLASTY, AND A DISCREPANCY WAS LATER NOTED WHEREIN THE PATIENT LABEL IDENTIFIED THE DEVICE AS CEMENTED. PRIOR TO IMPLANTATION, THE SURGICAL TEAM CONFIRMED WITH THE SURGEON THAT CEMENTLESS FIXATION WOULD BE USED. THE CIRCULATING NURSE OPENED THE PACKAGE, AND THE OUTER PACKAGING (BOX LID) INDICATED A CEMENTLESS/POROUS COMPONENT. SUBSEQUENTLY, IT WAS POINTED OUT THAT THE PATIENT LABEL INDICATED A CEMENTED VARIANT, WHILE THE IMPLANTED COMPONENT AND OUTER PACKAGING CORRESPONDED TO CEMENTLESS. THE PATIENT HAD NO KNOWN IMPACT OR CONSEQUENCE. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24209251 ↗
  • InjuryOct 15, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT A PATIENT UNDERWENT AN INITIAL TKA ON AN UNKNOWN DATE. SUBSEQUENTLY, THEY WERE REVISED DUE TO PAIN AND STIFFNESS. ALL FORMER IMPLANTS WERE REPLACED. TO ADDRESS THE OVERALL TIGHTNESS IN BOTH FLEXION AND EXTENSION, THE SURGEON DOWNSIZED THE FEMORAL COMPONENT, RESECTED MORE BONE OFF THE FEMUR AND TIBIA AND DEBRIDEMENT SIGNIFICANT AMOUNTS OF SCAR TISSUE. ATTEMPTS HAVE BEEN MADE, AND ALL AVAILABLE INFORMATION HAS BEEN PROVIDED.

    Patient problems: Loss of Range of Motion; Pain

    MAUDE report 23295452 ↗
  • InjuryMay 6, 2022Adverse Event Without Identified Device or Use Problem; Loosening of Implant Not Related to Bone-Ingrowth; Adverse Event Without Identified Device or Use Problem; Loosening of Implant Not Related to Bone-Ingrowth

    IT WAS REPORTED THAT A PATIENT UNDERWENT A KNEE SURGERY ON AN UNKNOWN DATE. SUBSEQUENTLY, THE PATIENT WAS REVISED LAST YEAR DUE TO UNKNOWN REASONS. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.

    Patient problems: Failure of Implant; Insufficient Information

    MAUDE report 14307953 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K023546, K033489, K113550, K171054. One submission often covers many models, so check the product and lot details in each record.

  • Z-1043-2023 · Dec 29, 2022 · Open, Classified
    (1) Vanguard Knee System PS Open Box Femoral; Left; 57.5 mm. Intended for Knee joint replacement prostheses. Item Number: 183122 EXPANDED RECALL: (2) Vanguard Knee System PS Ope
  • Z-1042-2023 · Dec 29, 2022 · Open, Classified
    (1) Vanguard Knee System PS Open Box Femoral; Right; 60 mm. Intended for knee joint replacement prostheses. Item Number: 183104 (2) Vanguard Knee System PS Open Box Femoral; Right
  • Z-2153-2020 · Apr 17, 2020 · Terminated
    Knee Products: 183742 Vanguard Knee System, PS+ Tibial Bearing, 12 MM, 71/75 MM EP-183608 Vanguard Knee System, PS Tibial Bearing, E1 Infused, 18 MM X 59 MM EP-183608 Vang
  • Z-2150-2020 · Apr 17, 2020 · Terminated
    Knee Products: 183622 Vanguard Knee System PS Tibial Bearing, 12 MM X 63/67 MM 183620 Vanguard Knee System PS Tibial Bearing, 10 MM X 63/67 MM 189048 Vanguard Knee System, AS Tibia
  • Z-0938-2019 · Dec 21, 2018 · Terminated
    Vanguard Knee System Series-A Standard Patella sizes 34mm Item Number: 184766
  • Z-0495-2019 · Oct 22, 2018 · Terminated
    Vanguard Knee System -PS Open Box Femoral Left, 62.5 mm Item Number: 183126
  • Z-0496-2019 · Oct 22, 2018 · Terminated
    Vanguard Knee System -PS Open Box Femoral Right, 65 mm Item Number:183108
  • Z-2289-2018 · May 24, 2018 · Terminated
    Vanguard Complete Knee System; E1 Vanguard PS Tibial Bearing; Model Numbers EP-183664, EP-183642 Product Usage: The product is intended for use in knee joint replacement arthropla
  • Z-2177-2018 · May 18, 2018 · Terminated
    Biomet Modular Primary Tibial Tray Implants; Modular Interlok Primary Tray (size 75 mm); Item No. 141215; UDI: (01) 00880304005310 (17) 280306 (10) 385340 Product is used in Total
  • Z-2183-2018 · May 11, 2018 · Terminated
    Vanguard Knee System PS Tibial Bearing, Part Number 183621 Intended for use in knee joint replacement procedures.
  • Z-1011-2018 · Oct 3, 2017 · Terminated
    Vanguard CR Porous Femoral 62.5mm (Left Femur) For use in total knee arthroplasty
  • Z-0673-2018 · Sep 29, 2017 · Terminated
    Vanguard Complete Knee System, Vanguard CR Tibial Bearing 12x71/75, Item Number: 183442 Product Usage: For use in total knee arthroplasty
  • Z-0674-2018 · Sep 29, 2017 · Terminated
    Vanguard Complete Knee System, Vanguard CR Lipped Tibial Bearing 10x71/75, Item Number: 183540 Product Usage: For use in total knee arthroplasty
  • Z-1115-2017 · Jan 4, 2017 · Terminated
    Vanguard Total Knee System Vanguard Open Box Femoral Components Item Number: 183100 Description: VNGD PS OPEN INTL FEM RT 55 Item Number: 183102 Description: VNGD PS OPEN INTL FEM
  • Z-0111-2017 · Aug 9, 2016 · Terminated
    Vanguard Distal Femoral Augment 75 X 5 RL/LM Product Usage: Painful and disabled knee joint resulting from osteoarthritis, rheumatoid arthritis, traumatic arthritis where one or

…and 5 more.

Other PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page