Skip to content

RINGLOC + HIP SYSTEM 106024Recalls & reported problems

Biomet Orthopedics, LLC · Class 2 · Implant

All models of RingLoc Hip System (40)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00880304455078), received between Jan 20, 2020 and Jan 20, 2020 — classified as 1 injury.

19 other recalls cover devices cleared under the same FDA submission (K070369); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Extraskeletal ossification1
  • Pain1
  • Scar Tissue1
  • Unspecified Infection1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 20, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT PATIENT UNDERWENT RIGHT REVISION AND SUBSEQUENTLY, PATIENT UNDERWENT ANOTHER REVISION A YEAR AND A HALF LATER DUE TO INFECTION. ALL COMPONENTS WERE REMOVED AND A CEMENT SPACER IMPLANTED. ATTEMPTS WERE MADE TO OBTAIN ADDITIONAL INFORMATION; HOWEVER, NONE WAS AVAILABLE.

    Patient problems: Extraskeletal ossification; Pain; Scar Tissue; Unspecified Infection

    MAUDE report 9608261 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K070369. One submission often covers many models, so check the product and lot details in each record.

  • Z-2463-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Limited Hole Acetablular Cup, 52 mm Size 23, with Locking Ring, sterile, REF PT-116052, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ringl
  • Z-2452-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Solid Acetablular Cup w/Apical Hole, 64 mm Size 26, w/Lock Ring w/Plug, sterile, REF PT-104064, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenere
  • Z-2465-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Limited Hole Acetablular Cup, 56 mm Size 24, with Locking Ring, sterile, REF PT-116056, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ring
  • Z-2466-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Limited Hole Acetablular Cup, 60 mm Size 25, with Locking Ring, sterile, REF PT-116060, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ring
  • Z-2462-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Limited Hole Acetablular Cup, 50 mm Size 22, with Locking Ring, sterile, REF PT-116050, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ringl
  • Z-2464-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Limited Hole Acetablular Cup, 54 mm Size 23, with Locking Ring, sterile, REF PT-116054, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ring
  • Z-2454-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Multi Hole Acetablular Cup, 56 mm Size 24, with Lock Ring, sterile, REF PT-106056, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ringloc is
  • Z-2456-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Multi Hole Acetablular Cup, 62 mm Size 25, with Lock Ring, sterile, REF PT-106062, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ringloc is
  • Z-2459-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Multi Hole Acetablular Cup, 70 mm Size 27, with Lock Ring, sterile, REF PT-106070, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ringloc is
  • Z-2460-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Multi Hole Acetablular Cup, 74 mm Size 28, with Lock Ring, sterile, REF PT-106074, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ringloc is
  • Z-2450-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Solid Acetablular Cup w/Apical Hole, 56 mm Size 24, w/Lock Ring w/Plug, sterile, REF PT-104056, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenere
  • Z-2461-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Limited Hole Acetablular Cup, 48 mm Size 22, with Locking Ring, sterile, REF PT-116048, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ring
  • Z-2448-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Solid Acetablular Cup w/Apical Hole, 50 mm Size 22, w/Lock Ring w/Plug, sterile, REF PT-104050, Biomet Orthopedics, Warsaw, IN. Intended Use: The Porous
  • Z-2455-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Multi Hole Acetablular Cup, 60 mm Size 25, with Lock Ring, sterile, REF PT-106060, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ringloc is
  • Z-2457-2011 · Apr 14, 2011 · Terminated
    Regenerex (TM) Ringloc +, Multi Hole Acetablular Cup, 64 mm Size 25, with Lock Ring, sterile, REF PT-106064, Biomet Orthopedics, Warsaw, IN. Intended Use: The Regenerex Ringloc is

…and 4 more.

Other Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices

All Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices →

Sources and updates