Adverse event reports
5
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00880304465787), received between Oct 24, 2019 and Nov 11, 2024 — classified as 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Unstable” (2 reports).

9 other recalls cover devices cleared under the same FDA submission (K080528, K113550, K171054); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unstable2
  • Device-Device Incompatibility1
  • Fracture1
  • Loosening of Implant Not Related to Bone-Ingrowth1
  • Off-Label Use1
  • Positioning Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Pain2
  • Burning Sensation1
  • Failure of Implant1
  • Insufficient Information1
  • Joint Swelling1
  • Limited Mobility Of The Implanted Joint1
  • Loss of Range of Motion1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 11, 2024Fracture; Fracture

    IT WAS REPORTED THAT THE PATIENT UNDERWENT A LEFT KNEE ARTHROPLASTY REVISION TO ADDRESS TIBIAL BEARING FRACTURE AND DISCOMFORT APPROXIMATELY SIX (6) YEARS POST-OPERATIVELY. ATTEMPTS HAVE BEEN MADE; HOWEVER, NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: Failure of Implant; Pain

    MAUDE report 20652348 ↗
  • MalfunctionDec 19, 2023Positioning Failure; Positioning Failure

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18358468 ↗
  • MalfunctionJun 8, 2023Off-Label Use; Device-Device Incompatibility; Off-Label Use; Device-Device Incompatibility

    IT WAS REPORTED THAT A PATIENT UNDERWENT A REVISION KNEE PROCEDURE FOR A POLYETHYLENE INSERT EXCHANGE. AFTER THE PROCEDURE, IT WAS DETERMINED THAT THE NEWLY IMPLANTED ARTICULAR SURFACE IS NOT COMPATIBLE WITH THE PREVIOUSLY IMPLANTED FEMORAL COMPONENT. NO ADDITIONAL MEDICAL INTERVENTION HAS BEEN REPORTED TO CORRECT THE INCORRECTLY IMPLANTED COMPONENT. DUE DILIGENCE IS IN PROGRESS FOR THIS EVENT; TO DATE NO ADDITIONAL INFORMATION HAS BEEN PROVIDED.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 17088971 ↗
  • InjuryJan 8, 2020Unstable; Unstable

    PATIENT REPORTED TO HAVE UNDERGONE RIGHT TOTAL KNEE ARTHROPLASTY. SUBSEQUENTLY, PATIENT UNDERWENT A REVISION PROCEDURE APPROXIMATELY 26 MONTHS POST-IMPLANTATION DUE TO LOOSENING, PAIN, BURNING SENSATION AND AN ALLERGY TO BONE CEMENT.

    Patient problems: Burning Sensation; Pain; Reaction

    MAUDE report 9564024 ↗
  • InjuryOct 24, 2019Unstable; Loosening of Implant Not Related to Bone-Ingrowth; Unstable; Loosening of Implant Not Related to Bone-Ingrowth

    NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: Joint Swelling; Limited Mobility Of The Implanted Joint; Loss of Range of Motion

    MAUDE report 9233586 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K080528, K113550, K171054. One submission often covers many models, so check the product and lot details in each record.

  • Z-1043-2023 · Dec 29, 2022 · Open, Classified
    (1) Vanguard Knee System PS Open Box Femoral; Left; 57.5 mm. Intended for Knee joint replacement prostheses. Item Number: 183122 EXPANDED RECALL: (2) Vanguard Knee System PS Ope
  • Z-1042-2023 · Dec 29, 2022 · Open, Classified
    (1) Vanguard Knee System PS Open Box Femoral; Right; 60 mm. Intended for knee joint replacement prostheses. Item Number: 183104 (2) Vanguard Knee System PS Open Box Femoral; Right
  • Z-0938-2019 · Dec 21, 2018 · Terminated
    Vanguard Knee System Series-A Standard Patella sizes 34mm Item Number: 184766
  • Z-0495-2019 · Oct 22, 2018 · Terminated
    Vanguard Knee System -PS Open Box Femoral Left, 62.5 mm Item Number: 183126
  • Z-0496-2019 · Oct 22, 2018 · Terminated
    Vanguard Knee System -PS Open Box Femoral Right, 65 mm Item Number:183108
  • Z-2289-2018 · May 24, 2018 · Terminated
    Vanguard Complete Knee System; E1 Vanguard PS Tibial Bearing; Model Numbers EP-183664, EP-183642 Product Usage: The product is intended for use in knee joint replacement arthropla
  • Z-2177-2018 · May 18, 2018 · Terminated
    Biomet Modular Primary Tibial Tray Implants; Modular Interlok Primary Tray (size 75 mm); Item No. 141215; UDI: (01) 00880304005310 (17) 280306 (10) 385340 Product is used in Total
  • Z-2183-2018 · May 11, 2018 · Terminated
    Vanguard Knee System PS Tibial Bearing, Part Number 183621 Intended for use in knee joint replacement procedures.
  • Z-1011-2018 · Oct 3, 2017 · Terminated
    Vanguard CR Porous Femoral 62.5mm (Left Femur) For use in total knee arthroplasty

Other PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER devices

All PROSTHESIS, KNEE, FEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page