Arcos Modular Revision Hip System 11-301620Recalls & reported problems
Biomet Orthopedics, LLC · Class 2 · Implant
All models of Arcos Modular Revision Hip System (71)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00880304473775), received between Sep 14, 2023 and Sep 14, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Migration1
- Migration or Expulsion of Device1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 14, 2023Migration or Expulsion of Device; Migration; Migration or Expulsion of Device; Migration
IT WAS REPORTED THAT DURING A REVISION OF UNKNOWN DEVICES, THE DOCTOR NOTED THAT THE ACETABULUM WAS NOT PREPARED CORRECTLY; THEREFORE, INSERTED THE CUP WITH FIXATION OF FOUR SCREWS. DURING THE ATTEMPTS OF REDUCTION, ENCOUNTERED DIFFICULTY AND UPON DELIVERY OF FORCE, LED TO ROTATION OF THE PRESS-FIT FEMORAL STEM. A CURVED STEM WAS THEN PLACED AND AS ADDITIONAL REDUCTION ATTEMPTS WERE MADE, THE STEM ALSO ROTATED, LEADING TO THE STEM BEING CEMENTED. IN THE PROCESS OF TESTING THE HIP, ONE EVENT OF DISLOCATION OCCURRED; THEREFORE, ADDITIONAL REDUCTION MANEUVERS WERE REPEATED. THE PROCEDURE WAS COMPLETED AND THE PATIENT WAS TRANSPORTED OUT OF THE OR. AFTER APPROXIMATELY 1 HOUR, THE PATIENT WAS RETURNED TO THE OR DUE TO DISLOCATION. THE LINER WAS REVISED TO A FREEDOM LINER AND WAS SUCCESSFULLY REDUCED WITHOUT DISLOCATION. SUBSEQUENTLY, DUE TO THE USE OF TENSILE FORCE, THE CUP DETACHED FROM THE ACETABULAR WALL AND THE PATIENT WAS HOSPITALIZED HIP PENDENT. THERE IS NO ADDITIONAL INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Failure of Implant
MAUDE report 17744750 ↗
Other Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate devices
- Novation 130-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls156 reports
- Novation 130-36-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls79 reports
- CORAIL 3L92511Depuy (Ireland) · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate158 reports
- Acumatch A Series 138-36-29Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate3 recalls1 report
- Novation 136-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls43 reports
- Novation 130-32-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls33 reports
- Novation 132-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls26 reports
- Novation 136-36-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls22 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page