Biomet® 360 Knee System 185204Recalls & reported problems
Biomet Orthopedics, LLC · Class 2 · Implant
All models of BIOMET 360 KNEE SYSTEM (13)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00880304481435), received between Jan 12, 2021 and Sep 23, 2026 — classified as 4 injuries, 1 malfunction.
The most frequently reported specific device problem is “Migration” (2 reports).
5 other recalls cover devices cleared under the same FDA submission (K093293, K140883); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Migration2
- Corroded1
- Device Dislodged or Dislocated1
- Difficult to Insert1
- Loosening of Implant Not Related to Bone-Ingrowth1
- Unstable1
Patient problems
- Ambulation or Postural Difficulties2
- Failure of Implant2
- Pain2
- High metal ion levels1
- Loss of Range of Motion1
- Metal Related Pathology1
- No Clinical Signs, Symptoms or Conditions1
- Osteopenia/ Osteoporosis1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 23, 2026Difficult to Insert
It was reported that the locking bar didn't fit in the bearing and the tibial tray, so the surgery was completed with a new locking bar. The surgeon suspected that the locking bar and bearing might have been deformed prior to use as they could not smoothly insert the locking bar into the tibial plate. There was a less than 30 minute surgical delay. The surgical technique was utilized. Attempts have been made and all available information has been provided.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50867958 ↗InjuryJan 6, 2026Corroded
IT WAS REPORTED PATIENT HAS METALLOSIS IN RIGHT KNEE APPROXIMATELY 10 YEARS POST IMPLANTATION. NO INTERVENTION HAS BEEN REPORTED TO DATE. ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION HAVE BEEN MADE; HOWEVER, NO MORE IS AVAILABLE AT THIS TIME.
Patient problems: Ambulation or Postural Difficulties; High metal ion levels; Metal Related Pathology
MAUDE report 23973114 ↗InjuryOct 13, 2021Unstable; Loosening of Implant Not Related to Bone-Ingrowth; Unstable; Loosening of Implant Not Related to Bone-Ingrowth
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Ambulation or Postural Difficulties; Failure of Implant; Loss of Range of Motion; Pain; Peripheral Nervous Injury
MAUDE report 12623636 ↗InjuryJun 28, 2021Device Dislodged or Dislocated; Migration; Device Dislodged or Dislocated; Migration
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Failure of Implant
MAUDE report 12076445 ↗InjuryJan 12, 2021Migration; Migration
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Osteopenia/ Osteoporosis; Pain
MAUDE report 11156394 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K093293, K140883. One submission often covers many models, so check the product and lot details in each record.
- Z-0723-2021 · Dec 1, 2020 · TerminatedVanguard 360 Revision System Posterior Augment With Bolt - Product Usage: intended for use in knee arthroplasty Item Number: 185422
- Z-3249-2018 · Aug 2, 2018 · TerminatedVanguard 360 Revision Knee System 63x 10mm Universal Tibial Block Augment, Model Number 185221 Intended for use in Total Knee Arthroplasty
- Z-3250-2018 · Aug 2, 2018 · TerminatedVanguard 360 Revision Knee System 75x 5mm Universal Tibial Block Augment, Model Number 185224 Intended for use in Total Knee Arthroplasty
- Z-0003-2017 · Aug 8, 2016 · TerminatedVanguard 360 Revision Knee System Knee prostheses
- Z-2242-2014 · Jul 1, 2014 · TerminatedVanguard 360 Femoral Boss Reamer, Label: REF 32-488474 VANGUARD 360 1NSTRUMENT FEMORAL BOSS REAMER NON-STERILE, BIOMET ORTHOPEDICS 56 EAST BELL DRIVE P.O. BOX 587 WARSAW, IN 4658
Other Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer devices
- Regenerex 141356Biomet Orthopedics, LLC · Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer1 recall5 reports
- BIOMET KNEE SYSTEM 141215Biomet Orthopedics, LLC · Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer1 recall3 reports
- Regenerex 141358Biomet Orthopedics, LLC · Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer1 recall1 report
- Vanguard Knee System 189320Biomet Orthopedics, LLC · Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer1 recall0 reports
- Vanguard Knee System 189704Biomet Orthopedics, LLC · Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer1 recall0 reports
- Vanguard Knee System 189720Biomet Orthopedics, LLC · Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer1 recall0 reports
- Vanguard Knee System EP-183608Biomet Orthopedics, LLC · Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer1 recall0 reports
- VANGUARD 32-360500Biomet Orthopedics, LLC · Prosthesis, knee, patello/femorotibial, semi-constrained, uhmwpe, pegged, cemented, polymer/metal/polymer4 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page