G7 Acetabular Liner 010000942Recalls & reported problems
Biomet Orthopedics, LLC · Class 2 · Implant
All models of G7 Acetabular Liner (85)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00880304527164), received between Jul 2, 2020 and Dec 8, 2025 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Detachment of Device or Device Component1
- Difficult to Insert1
- Noise, Audible1
- Positioning Failure1
- Unstable1
Patient problems
- Pain2
- Ambulation or Postural Difficulties1
- Discomfort1
- Limited Mobility Of The Implanted Joint1
- No Clinical Signs, Symptoms or Conditions1
- Reaction1
- Swelling1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryDec 8, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
NO FURTHER INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.
Patient problems: Ambulation or Postural Difficulties; Pain
MAUDE report 23737364 ↗MalfunctionJan 3, 2023Positioning Failure; Difficult to Insert; Positioning Failure; Difficult to Insert
IT WAS REPORTED THAT THE LINER WOULD NOT ENGAGE IN THE CUP UPON IMPACTION. ANOTHER LINER WAS OPENED, AND THE IMPACTION WAS SUCCESSFUL. NO DEBRIS FELL NOR WAS THERE ANY CONSEQUENCES OR IMPACT TO THE PATIENT. ATTEMPTS HAVE BEEN MADE AND NO FURTHER INFORMATION HAS BEEN PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16088085 ↗InjuryJul 2, 2020Unstable; Detachment of Device or Device Component; Noise, Audible; Unstable; Detachment of Device or Device Component; Noise, Audible
IT WAS REPORTED PATIENT UNDERWENT A HIP REVISION APPROXIMATELY FOUR MONTHS POST IMPLANTATION DUE TO POLY LINER DETACHMENT FROM CUP. DURING THE PROCEDURE, THE HEAD WAS NOTED TO HAVE ARTICULATED ON THE METAL CUP, SO BOTH THE HEAD AND LINER COMPONENTS WERE REMOVED AND REPLACED. PATIENT EXPERIENCED DISCOMFORT AND RESTRICTED DAILY ACTIVITIES. ATTEMPTS HAVE BEEN MADE AND ADDITIONAL INFORMATION ON THE REPORTED EVENT IS UNAVAILABLE AT THIS TIME.
Patient problems: Discomfort; Limited Mobility Of The Implanted Joint; Pain; Reaction; Swelling
MAUDE report 10224499 ↗
Other Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented devices
- AcuMatch 142-32-27Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented2 recalls0 reports
- Novation 140-36-52Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall8 reports
- G7 DEPTH GAUGE 110010717Biomet Orthopedics, LLC · Hip, semi-constrained, cemented, metal/ceramic/polymer + additive, porous uncemented54 reports
- Novation 140-32-52Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall2 reports
- Novation 142-32-61Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall1 report
- Novation 140-36-54Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall1 report
- Novation 142-32-51Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall0 reports
- Novation 142-40-64Exactech, Inc. · Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page