Merit Medical® 00884450387320Recalls & reported problems
Merit Medical Systems, Inc. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450387320), received between Feb 6, 2020 and Feb 6, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Crack” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Crack1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 6, 2020Crack; Crack
THE ACCOUNT ALLEGES THAT DURING A PERCUTANEOUS TRANSLUMINAL CORONARY INTERVENTION [PCI] PROCEDURE, THE PHYSICIAN HAD ACQUIRED RETROGRADE ARTERIAL ACCESS AND HAD NEGOTIATED THE PATIENT'S AORTA WITH A GUIDEWIRE AND GUIDE CATHETER TO SUCCESSFULLY CANNULATE AND OPACIFY THE CORONARY VASCULAR SYSTEM. THE ACCOUNT STATES THAT FOLLOWING A BALLOON ANGIOPLASTY, AIR WAS IDENTIFIED WITHIN THE INJECTION MANIFOLD. THE MANIFOLD SYRINGE WAS PULLED BACK AND A CRACK WAS IDENTIFIED AT THE CONTROL SYRINGE CONNECTION PORT. A NEW MANIFOLD WAS PREPPED PER INDUSTRY PROTOCOL, AND THE PROCEDURE CONTINUED. AIR WAS NOT IDENTIFIED -UNDER FLUOROSCOPIC IMAGING- ENTERING THE PATIENT DURING THIS PROCEDURE. THE PHYSICIAN THEN NOTED TWO NEW FILLING DEFECTS WITHIN THE PATIENT'S ARTERY. THE PATIENT BECAME PROGRESSIVELY HYPOTENSIVE AND A CODE BLUE WAS INITIATED. RETURN OF SPONTANEOUS CIRCULATION (ROSC) WAS SUCCESSFULLY ACHIEVED AND THE PROCEDURE CONTINUED. SEVENTEEN MINUTES LATER, THE PATIENT CODED AGAIN. THE TEAM WAS NOT ABLE TO RECOVER THE PATIENT. THE PATIENT EXPIRED ON THE PROCEDURE ROOM TABLE. THE ACCOUNT ALLEGES THAT THE CAUSE OF DEATH WAS AN ANTERIOR WALL MYOCARDIAL INFARCTION, SECONDARY TO THROMBOSIS OF A HIGH-G
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9679257 ↗
Other Cardiovascular procedure kit devices
- Medline Industries, Inc. CDS840396YMedline Industries, Inc. · Cardiovascular procedure kit6 recalls0 reports
- Medline Industries, Inc. CDS983513FMedline Industries, Inc. · Cardiovascular procedure kit6 recalls0 reports
- Medline Industries, Inc. CDS840396XMedline Industries, Inc. · Cardiovascular procedure kit5 recalls0 reports
- Medline Industries, Inc. CDS984355GMedline Industries, Inc. · Cardiovascular procedure kit5 recalls0 reports
- Medline Industries, Inc. DYNJ51038RMedline Industries, Inc. · Cardiovascular procedure kit4 recalls2 reports
- NAMIC 60033123Medline Industries, Inc. · Cardiovascular procedure kit4 recalls0 reports
- Medline Industries, Inc. DYNJ905079FMedline Industries, Inc. · Cardiovascular procedure kit4 recalls0 reports
- Medline Industries, Inc. DYNJ0376608OMedline Industries, Inc. · Cardiovascular procedure kit4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page