Skip to content

EndoMAXX® 00884450442371Recalls & reported problems

Merit Medical Systems, Inc. · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00884450442371), received between Oct 19, 2023 and Oct 19, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 19, 2023Fracture; Adverse Event Without Identified Device or Use Problem; Fracture; Adverse Event Without Identified Device or Use Problem

    THE ACCOUNT ALLEGES THAT THE CUSTOMER WAS DX WITH MALIGNANCY AT THE GE JUNCTION, AND A COMPETITOR'S ESOPHAGEAL STENT WAS PLACED AT ANOTHER HOSPITAL. ON WEDNESDAY, (B)(6) 2023, AN EGD WAS PERFORMED WHERE THE COMPETITOR'S STENT WAS IDENTIFIED TO HAVE MIGRATED INTO THE STOMACH. THE DISTAL ESOPHAGUS WAS STRICTURED DOWN, WHERE THEY COULD NOT PASS A PEDIATRIC EGD STOMACH TO RETRIEVE THE STENT. THE DECISION WAS MADE TO USE AN ESOPHAGEAL STENT TO OPEN THE STRICTURE AND HAVE A FOLLOW-UP EGD TO RETRIEVE THE COMPETITOR'S STENT. THE PHYSICIAN PLACED AN ESOPHAGEAL STENT AND THEN DECIDED TO TELESCOPE ANOTHER STENT OVERLAPPING 3 CMS. THEY BROUGHT PATIENT BACK ON FRIDAY (B)(6) TO PERFORM EGD TO PULL THE COMPETITORS' STENT INTO THE ESOPHAGEAL STENT AND THEN REMOVE ALL REMAINING STENTS. WHEN REMOVING THE MOST PROXIMAL STENT ALL 3 STENTS WERE STILL CONNECTED AND MOVING TOGETHER. THE PROXIMAL END BROKE OFF IN THE PATIENT. THE PHYSICIAN TRIED USING A DUAL CHANNEL SCOPE AND REMOVE USING TWO GRASPERS BUT WAS UNABLE TO. THE DECISION WAS THEN MADE TO ADMIT PATIENT AND BRING IN ENT SURGEON TO ASSIST. ON SUNDAY (B)(6), THE ENT SURGEON PERFORMED A SUSPENSION LARYNGOSCOPY AND WAS ABLE TO REMOVE THE ESOPHAGEAL

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17965414 ↗

FDA clearance and classification

The FDA regulates product code ESW (prosthesis, esophageal) under 21 CFR 878.3610 as a Class II device. 21 CFR 878.3610 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the EndoMAXX® 00884450442371

Has the EndoMAXX® 00884450442371 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00884450442371), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the EndoMAXX® 00884450442371?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Oct 19, 2023. That report lists device problem “Fracture” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the EndoMAXX® 00884450442371?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the EndoMAXX® 00884450442371 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the EndoMAXX® 00884450442371, and is it still sold?

The FDA's device database lists Merit Medical Systems, Inc. as the company responsible for it (brand EndoMAXX®, model 00884450442371). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other PROSTHESIS, ESOPHAGEAL devices

All PROSTHESIS, ESOPHAGEAL devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page